NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Direct estimation of fetal biometry measurements from ultrasound video scans through deep learning

Szymon Płotka, Karol Pustelnik, Paula Szenejko, Kinga Żebrowska, Iga Rzucidło-Szymańska, Natalia Szymecka-Samaha, Tomasz Łęgowik, Katarzyna Kosińska–Kaczyńska, Przemysław Korzeniowski, Piotr Biliński, Asma Khalil, Robert Brawura-Biskupski-Samaha, Ivana Išgum, Clara I. Sá‎nchez, Arkadiusz Sitek, Szymon PlotkaAmerican 2025 · OpenAlex

Abstract

Researchers have developed a deep learning (DL) pipeline that automatically extracts fetal biometry measurements—such as head circumference and femur length—directly from ultrasound video sweeps. By eliminating the need for sonographers to manually "freeze" and measure specific frames, this method achieves accuracy comparable to senior clinicians and could significantly reduce the time and subjectivity inherent in prenatal screenings.

Introduction

Measuring a fetus during an ultrasound (fetal biometry) is a cornerstone of prenatal care, used to monitor growth and estimate gestational age. However, the current gold standard is fraught with "human" bottlenecks. A sonographer must navigate the probe to find a highly specific "standard plane" (a perfect cross-section of the head, abdomen, or femur), freeze the image, and manually place calipers to take measurements.

This process is time-consuming and highly dependent on the operator's skill level. Even among experts, there is significant "interobserver variability"—two doctors might look at the same fetus and come up with slightly different numbers. This study aims to solve this by creating an automated system that can "watch" a 10–20 second video sweep and calculate all necessary measurements without human intervention.

Methodology

The authors propose a two-stage deep learning architecture designed to mimic and then automate the clinical workflow:

Stage 1: Standard Plane Detection

The first stage analyzes the raw ultrasound video (usually a 5–10 second sweep) to identify and select the most relevant "standard plane" frames for the head, abdomen, and femur.

The Standard Plane Detector (SPD) stage identifies and filters relevant frames from the input ultrasound video.

Stage 2: Biometry Estimation

Once the frames are selected, they are passed into a second network consisting of a Regression Feature Extractor (RFE) and a Key Frame Attention (KFA) module. Instead of performing simple image segmentation, the KFA module allows the AI to weigh the importance of different frames in the video sequence, effectively "deciding" which views provide the most reliable data for the final measurement.

The second stage utilizes a Key Frame Attention (KFA) module to estimate fetal biometry metrics from the selected feature tensors.

The output is a complete set of biometry data: Head Circumference (HC), Biparietal Diameter (BPD), Abdominal Circumference (AC), Femur Length (FL), Gestational Age (GA), and Estimated Fetal Weight (EFW).

Experimental Setup

The study utilized a retrospective dataset collected between 2021 and 2023 from two medical centers in Warsaw, Poland. The model was trained on recordings from seven sonographers and tested on a separate set of 100 fetal ultrasound samples from three different sonographers to ensure generalizability. To validate the AI, its results were compared against six human readers: three senior gynecologists (10–15 years experience), two junior residents, and one senior radiologist (>20 years experience).

Results and Discussion

The DL model demonstrated high precision across all metrics:

  • Overall Accuracy: The mean absolute percentage error (MAPE) for full fetal biometry was 2.91%.
  • Reliability: The Intraclass Correlation Coefficient (ICC) ranged from 0.9763 to 0.9857, indicating near-perfect agreement with human experts.
  • Expert Alignment: One of the most compelling findings was that the DL model’s measurements were closer to those of senior clinicians than junior residents were, suggesting the tool could act as a "leveler" in clinical settings.
  • Efficiency: Because the model works on video sweeps where no pauses are made for manual measurements, it hints at a future where ultrasound exams are significantly faster.

Conclusion and Future Work

While promising, the study is limited by a homogeneous population (European descent) and the use of specific hardware (GE devices). Future work must include prospective studies to prove clinical utility in real-time and validation across more diverse global populations and different ultrasound machine manufacturers.

Summary updated

BibTeX
@inproceedings{potka2025direct,
  author = {Szymon Płotka and Karol Pustelnik and Paula Szenejko and Kinga Żebrowska and Iga Rzucidło-Szymańska and Natalia Szymecka-Samaha and Tomasz Łęgowik and Katarzyna Kosińska–Kaczyńska and Przemysław Korzeniowski and Piotr Biliński and Asma Khalil and Robert Brawura-Biskupski-Samaha and Ivana Išgum and Clara I. Sá‎nchez and Arkadiusz Sitek and Szymon Plotka},
  title = {{Direct estimation of fetal biometry measurements from ultrasound video scans through deep learning}},
  booktitle = {American},
  year = {2025},
  doi = {10.1016/j.ajogmf.2025.101623},
}

Loading related content...

Figure