NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Damage Threshold of Oscillator Mirrors in Mark III FEL

Dag Deacon, Sv Benson, J.m.j. Madey, Julius SchultzOpenalex Unknown 1988 · OpenAlex

Abstract

We have observed damage of gold resonator mirrors in the Mark III FEL with 1.2 microsecond macropulses at a fluence threshold of 21 J/cm2. This number agrees with YAG laser damage measurements scaled by the square root of the ratio of the pulse lengths. Silver coated mirrors have not shown damage up to an equivalent threshold of 40 J/cm2. Work aimed at increasing the pulse energy on the silver mirrors is continuing; we expect to extend these measurements in the near future.
BibTeX
@inproceedings{deacon1988damage,
  author = {DAG Deacon and SV Benson and J.M.J. Madey and Julius Schultz},
  title = {{Damage Threshold of Oscillator Mirrors in Mark III FEL}},
  booktitle = {Openalex Unknown},
  year = {1988},
  doi = {10.1520/stp24449s},
}