This corrigendum serves to correct layout errors in the original research article titled "Increasing the sensor channels: a solution for the pressing offsets that cause the physiological parameter inaccuracy in radial artery pulse signal acquisition" (DOI: 10.3389/fbioe.2024.1359297). The correction restores vital data visualizations—specifically 3D spatial maps—that were inadvertently duplicated or omitted during the initial publication process.

The Challenge of Radial Artery Pulse Acquisition

Capturing accurate physiological signals from the radial artery using wearable devices is complicated by spatial sensitivity. Traditional single-channel sensors require precise alignment with the artery; even a minor "pressing offset" or shift in position can lead to significant inaccuracies in calculated parameters like blood pressure or arterial stiffness.

Multi-Channel Sensing as a Robust Solution

To address these offsets, the study proposes increasing the number of sensor channels. By employing a multi-channel tactile sensor array, the system can capture pulse waves from multiple points simultaneously. This spatial redundancy ensures that even if the wearable device shifts during use, the "optimal zone" of signal quality is still captured by one or more sensors in the array.

Methodology: 3D Pressure Index (3DPI) Mapping

The researchers evaluated signal quality using a normalized 3D Pressure Index (3DPI). By plotting this index against the physical dimensions (width and length) of the sensor array, they created 3D surface maps that identify the "sweet spot" for signal acquisition.

Figure 8: Normalized 3DPI in the T2 phase for male (A) and female (B) subjects. The peaks represent the optimal alignment zones over the radial artery.

Key Findings and Demographic Consistency

The restored figures (Figures 8 and 10 in the original study) demonstrate that the multi-channel approach is effective across different demographic groups:

  • Gender-based cohorts: As seen in Figure 8, both male and female subjects exhibit a clear peak in signal quality, though the specific spatial characteristics may vary slightly due to physiological differences.
  • Health-status cohorts: The study also confirmed consistent spatial mapping for both hypertensive and non-hypertensive subjects.

These results indicate that the multi-channel array successfully captures the fall-off of signal quality as distance from the arterial center increases. This data allows for the algorithmic selection of the highest-quality channel, ensuring robust performance across diverse user profiles and real-world conditions.

Conclusion

The restoration of these 3D maps reinforces the study's conclusion: increasing sensor channels is a viable and effective solution for the pressing offsets that typically degrade wearable pulse signal accuracy. This methodology supports the development of more reliable, clinical-grade wearable health technology.

Summary updated

Abstract

[This corrects the article DOI: 10.3389/fbioe.2024.1359297.].
BibTeX
@inproceedings{chen2024corrigendum,
  author = {Chao Chen and Zhendong Chen and Hongmiin Luo and Bo Peng and Yinan Hao and Xiaohua Xie and Haiqing Xie and Xinxin Li},
  title = {{Corrigendum: Increasing the sensor channels: a solution for the pressing offsets that cause the physiological parameter inaccuracy in radial artery pulse signal acquisition}},
  booktitle = {Frontiers in Bioengineering and Biotechnology},
  year = {2024},
  doi = {10.3389/fbioe.2024.1487592},
}
Figure