NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Correction to: Evaluation of pharmacokinetic modeling strategies for in-vivo quantification of tau with the radiotracer [18F]MK6240 in human subjects

Nicolas J. Guehl, Dustin Wooten, Daniel Yokell, Sung‐Hyun Moon, Maëva Dhaynaut, Samantha Katz, Kirsten A. Moody, Codi Gharagouzloo, Aurélie Kas, Keith A. Johnson, Georges El Fakhri, Marc D. NormandinEuropean 2023 · OpenAlex

This document is a formal Correction (Erratum) to a previously published research article in the European Journal of Nuclear Medicine and Molecular Imaging. While the document itself is brief, it addresses a critical technical detail in the experimental methodology of a study focused on tau protein imaging in the human brain.

TL;DR

This correction updates the specific chemical composition of the buffer used for radiometabolite analysis in a study of the tau tracer [$^{18}$F]MK6240. The authors clarify that a 10mM sodium phosphate dibasic buffer was used for column backflushing, rather than the sodium formate buffer originally reported.

What Problem Does This Paper Address?

The original research (Guehl et al., 2019) evaluated pharmacokinetic modeling strategies for [$^{18}$F]MK6240, a high-affinity PET radiotracer used to quantify tau aggregates—a hallmark of Alzheimer’s disease and other tauopathies.

To accurately model how a tracer moves through the body and binds to the brain, researchers must perform metabolite correction. This involves analyzing blood samples to distinguish between the "parent" radiotracer and its breakdown products (metabolites). If the chemical procedure for this analysis is misreported, other labs cannot replicate the findings or validate the pharmacokinetic models. This correction ensures the technical record is accurate for future replication studies.

Methods

The correction pertains to the High-Performance Liquid Chromatography (HPLC) procedure used to separate the parent tracer from its metabolites.

Specifically, the authors corrected the description of the mobile phase used to "backflush" the catch column. In the original text, the buffer was identified as sodium formate. The corrected procedure specifies:

  • Buffer: 10mM sodium phosphate dibasic.
  • Organic Solvent: Acetonitrile (MeCN).
  • Ratio: 62.5/37.5 (Buffer/MeCN).

This specific mixture is used to wash the trapped radiotracer off a primary column for further analysis, a standard but sensitive step in radiochemistry.

Datasets

Not discussed in the paper. (Note: The original 2019 study involved human subjects for in-vivo PET imaging, but this correction notice does not provide or alter the dataset itself.)

Key Insights and Ideas

  • Precision in Radiochemistry: In HPLC, the choice of buffer (e.g., phosphate vs. formate) significantly impacts the pH and ionic strength of the mobile phase. This, in turn, affects the retention time and separation efficiency of the radiotracer. Reporting the wrong buffer could lead to failed separations in attempted replications.
  • Integrity of Pharmacokinetic (PK) Models: PK modeling relies on an accurate "plasma input function." If the metabolite analysis is flawed due to incorrect chemical assumptions, the resulting quantification of tau in the brain (e.g., Volume of Distribution or Binding Potential) could be biased. By correcting the buffer type, the authors maintain the technical integrity of their modeling results.
  • The Importance of Errata: Formal corrections like this are vital for "Open Science." They demonstrate a commitment to accuracy, even for minor technical details that might not change the overall conclusion but are essential for the methodology's transparency.

Key Results

The primary result of this document is the replacement of one sentence in the original methodology:

  • Original: "...62.5/37.5 sodium formate buffer/MeCN was used..."
  • Corrected: "...62.5/37.5 10mM sodium phosphate dibasic buffer/MeCN was used..."

The authors do not indicate that this change affects the quantitative results or conclusions of the original 2019 study, suggesting the error was in the reporting of the reagent, not the execution of the experiment.

Limitations and Future Work

Not discussed in the paper. The document is limited to the specific correction of the buffer reagent. It does not propose new research directions or acknowledge limitations beyond the reporting error itself.

Summary updated

BibTeX
@inproceedings{guehl2023correction,
  author = {Nicolas J. Guehl and Dustin Wooten and Daniel Yokell and Sung‐Hyun Moon and Maëva Dhaynaut and Samantha Katz and Kirsten A. Moody and Codi Gharagouzloo and Aurélie Kas and Keith A. Johnson and Georges El Fakhri and Marc D. Normandin},
  title = {{Correction to: Evaluation of pharmacokinetic modeling strategies for in-vivo quantification of tau with the radiotracer [18F]MK6240 in human subjects}},
  booktitle = {European},
  year = {2023},
  doi = {10.1007/s00259-022-06102-2},
}

Loading related content...