Correction to: [18F]FDG PET/MRI combined with chest HRCT in early cancer detection: a retrospective study of 3020 asymptomatic subjects

Li‐Ling Peng, Yi Liao, Rui Zhou, Yan Zhong, Han Jiang, Jing Wang, Yu Fu, Le Xue, Xiaohui Zhang, Mingxiang Sun, Gang Feng, Zhaoting Meng, Sisi Peng, Xuexin He, Gao‐Jun Teng, Xin Gao, Hong Zhang, Mei TianEuropean 2023 · OpenAlex

Introduction

This article provides a formal correction to the retrospective study evaluating the efficacy of combined $[^{18}F]FDG$ PET/MRI and chest High-Resolution Computed Tomography (HRCT) for early cancer detection. The correction specifically addresses the "Methods" section of the original abstract to accurately reflect the study's cohort size and the duration of the clinical follow-up.

Corrected Methodology

The original research methodology required clarification regarding the scale and timeline of the study. The corrected parameters are as follows:

  • Study Population: The study involved a total of 3,020 asymptomatic subjects.
  • Imaging Protocol: All participants underwent whole-body $[^{18}F]FDG$ PET/MRI and chest HRCT examinations.
  • Follow-up Duration: To confirm cancer development and validate imaging results, all subjects received a 2–4-year follow-up.
  • Diagnostic Metrics: The researchers analyzed the cancer detection rate, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of $[^{18}F]FDG$ PET/MRI with and without the addition of chest HRCT.
The first page of the correction notice, listing the authors and their institutional affiliations.

The data for this large-scale analysis originated from several prominent medical institutions, including the Shanghai Universal Medical Imaging Diagnostic Center and Zhejiang University, reflecting a robust clinical dataset from high-level diagnostic centers.

Significance of the Study

The primary challenge in screening asymptomatic populations is the need for imaging modalities that offer both high sensitivity for early-stage malignancies and high specificity to avoid unnecessary follow-up procedures. While $[^{18}F]FDG$ PET/MRI provides a powerful combination of metabolic data and high-contrast soft-tissue anatomical imaging, its performance in a screening context—particularly when supplemented by chest HRCT for lung-specific screening—requires rigorous validation.

By correcting the methodology to reflect the true cohort size of 3,020 individuals and a multi-year follow-up, this notice ensures that the diagnostic performance metrics reported in the original work are correctly contextualized for the medical community.

Conclusion

Accurate methodological reporting is essential for the interpretation of clinical screening studies. This correction establishes the proper framework for the 3,020-subject retrospective study, confirming the parameters used to evaluate the diagnostic value of multi-modal PET/MRI and HRCT imaging in early cancer detection.

Summary updated

Abstract

MethodsThis study included a total of 3020 asymptomatic subjects who underwent whole-body [ 18 F]FDG PET/MRI and chest HRCT examinations.All subjects received a 2-4-year follow-up for cancer development.Cancer detection rate, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the [ 18 F]FDG PET/MRI with or without chest HRCT were calculated and analyzed.
BibTeX
@inproceedings{peng2023correction,
  author = {Li‐Ling Peng and Yi Liao and Rui Zhou and Yan Zhong and Han Jiang and Jing Wang and Yu Fu and Le Xue and Xiaohui Zhang and Mingxiang Sun and Gang Feng and Zhaoting Meng and Sisi Peng and Xuexin He and Gao‐Jun Teng and Xin Gao and Hong Zhang and Mei Tian},
  title = {{Correction to: [18F]FDG PET/MRI combined with chest HRCT in early cancer detection: a retrospective study of 3020 asymptomatic subjects}},
  booktitle = {European},
  year = {2023},
  doi = {10.1007/s00259-023-06370-6},
}
Figure