3D CBCT Artefact Removal Using Perpendicular Score-Based Diffusion Models

Susanne Schaub, Florentin Bieder, Matheus L. Oliveira, Yulan Wang, Dorothea Dagassan-Berndt, Michael M. Bornstein, Philippe C. Cattin

TL;DR

Researchers have developed a novel way to scrub "metal streaks" from dental 3D scans (CBCT) by using two perpendicular 2D diffusion models. By alternating between these models during the image-generation process, they achieve 3D consistency and higher image quality than standard 2D methods, all without the massive computational overhead of training a full 3D diffusion model.

What Problem Does This Paper Address?

Cone-beam computed tomography (CBCT) is a staple of modern dentistry, but it has a "kryptonite": metal. High-density objects like dental implants cause severe streaks and shadows (artifacts) in the final 3D reconstruction, which can hide pathologies or lead to diagnostic errors.

To fix this, researchers often use "inpainting"—essentially using AI to "guess" what the anatomy behind the metal looks like in the raw 2D projection data before the 3D image is even built. However, existing AI methods usually treat each 2D projection as an isolated image. Because they ignore the relationship between adjacent slices, the resulting 3D reconstructions often suffer from "flickering" or structural inconsistencies. Training a full 3D diffusion model to solve this is the obvious answer, but it is often computationally impossible for high-resolution medical data.

Methods

The authors introduce TPDM (Two Perpendicular Diffusion Models). Instead of one giant 3D model, they use two 2D score-based diffusion models:

  1. Primary Model: Trained on standard 2D projections (the $i-j$ plane).
  2. Secondary Model: Trained on slices perpendicular to the first (the $j-k$ plane).

The Secret Sauce: Perpendicular Sampling During the "denoising" process (where the AI turns noise into a clean image), the algorithm alternates between these two models. Every few steps, it switches planes. This forces the generated data to be consistent across both axes, effectively "knitting" the 2D projections into a coherent 3D volume.

To ensure the AI doesn't just hallucinate a random jaw, they use Diffusion Posterior Sampling (DPS). This technique conditions the model on the actual measured data (the parts of the scan not blocked by metal), ensuring the final result is anatomically accurate.

Datasets

Because it is nearly impossible to get "ground truth" scans of humans with and without implants, the researchers used a preclinical approach:

  • Source Data: CBCT scans of 10 fresh pig mandibles (which have similar bone density to humans) across four different scanner types (Morita, Planmeca, Dentsply-Sirona).
  • Simulation: They used the TIGRE Toolbox to synthesize 2D projections.
  • Artifacts: They mathematically inserted synthetic implants and simulated realistic physics-based errors like beam hardening and Poisson noise.
  • Scale: The training set included over 18,000 2D projections.

Key Insights and Ideas

  • 3D Coherence via 2D Priors: The most significant "aha" moment is that you don't need a 3D model to generate 3D data. By enforcing consistency in two perpendicular 2D planes, the 3D structure emerges naturally.
  • Unconditional Training: The models are trained on "clean" data only. They don't need to see examples of metal artifacts during training to know how to fix them during inference. This makes the model more robust to different implant shapes and sizes.
  • Efficiency Gains: Surprisingly, the TPDM approach was faster than the standard 2D DPS method (8.5 hours vs. 14 hours for a full stack) because it allowed for more efficient batching and required fewer iterations to reach a stable 3D result.

Key Results

The researchers compared TPDM against standard 2D Diffusion (DPS) and traditional Linear Interpolation (LI):

  • Higher Fidelity: TPDM achieved the best scores across all metrics. In the projection domain, it reached an SSIM of 0.9290, significantly outperforming 2D DPS (0.9110) and LI (0.8834).
  • Superior 3D Reconstruction: Once the 2D projections were turned into a 3D volume, TPDM maintained a higher PSNR (50.38 dB) compared to 2D DPS (49.90 dB), indicating fewer "hallucinated" errors.
  • Visual Clarity: Difference maps (comparing the results to the "perfect" reference) showed that TPDM had the smallest deviations, particularly in complex anatomical regions where 2D methods typically struggle.

Limitations and Future Work

  • Synthetic Gap: The study relied on simulated artifacts. While the physics simulations were rigorous, real-world clinical data involves complex "scatter" patterns that weren't fully modeled here.
  • Computational Cost: While more efficient than some alternatives, 8.5 hours to process a single scan is still too slow for a busy dental clinic. Future work will likely focus on "distilling" these models to run in minutes.
  • Scanner Geometry: The current method requires known scanner geometry to perform the reconstructions, which isn't always publicly available for proprietary commercial scanners.

The code for this project is available at: https://github.com/SusanneSchaub/TPDM_Implant_Inpainting

Summary updated

BibTeX
@inproceedings{schaub2025d,
  author = {Susanne Schaub and Florentin Bieder and Matheus L. Oliveira and Yulan Wang and Dorothea Dagassan-Berndt and Michael M. Bornstein and Philippe C. Cattin},
  title = {{3D CBCT Artefact Removal Using Perpendicular Score-Based Diffusion Models}},
  booktitle = {DGM4MICCAI @ MICCAI},
  year = {2025},
  url = {https://openreview.net/forum?id=ujkKfLSCCr},
}

Loading related content...

Figure