NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Where Simulated Homes Go Wrong: Concept Bottlenecks for Diagnosing the Residential Sim-to-Real Gap

Load forecasters pretrained on hundreds of thousands of simulated buildings transfer well to real offices. They transfer badly to real homes. In BuildingsBench, a model pretrained on 900,000 EnergyPlus-simulated buildings beats a previous-day persistence baseline zero-shot on real commercial buildings. On real residential buildings, simply averaging the past seven days often beats it (BuildingsBench). The authors suspect the simulated occupant schedules are too clean. The forecaster is a black box, though, so nobody can say whether the failure comes from the simulated physics (insulation, heating response) or the simulated people (when they are home, where they set the thermostat, how many appliances they run). This matters because the two causes call for different fixes: better envelope models in one case, better behavior models or real behavioral data in the other.

We propose to route the forecaster through a concept bottleneck. This is a narrow intermediate layer whose units are forced to predict named, human-meaningful quantities, and the final forecast is a simple function of those quantities alone. The bottleneck splits into a physics group and an occupant-behavior group. Simulation is what makes this feasible: every EnergyPlus building comes with its envelope parameters and occupancy, setpoint and plug-load schedules, so concept labels cost nothing. That removes the dense-annotation burden that limits ordinary concept bottlenecks (Concept Bottleneck Models). The split lets us test where the sim-to-real gap lives, measure how many real hours each concept group needs, and adapt only the part that is broken.

Core Claim

We hypothesize that the residential transfer failure is concentrated in the behavior half of the bottleneck. Two predictions follow, and both can be checked on real data. First, on real homes, the physics concepts the model predicts should agree with independently estimated physics quantities about as well as they do on commercial buildings, while the behavior concepts should drift. Second, refitting only the behavior encoder on a few weeks of a home's real data, with the simulation-trained physics path frozen, should recover most of the gain of full fine-tuning and need fewer real hours to do it. If both hold, the bottleneck becomes a tool for evaluating synthetic data concept by concept. It would give a separate synthetic-to-real "exchange rate" for physics and for behavior, extending the single equivalency ratio that On the Equivalency, Substitutability, and Flexibility of Synthetic Data measured for tracking video. If the hypothesis fails, and the physics concepts also break on homes, that is equally useful. It would mean the field's assumption that "the occupancy schedules are too clean" is wrong.

Relation to Prior Work

The closest method is Interpretability for Time Series Transformers using A Concept Bottleneck Framework. It removes the residual shortcuts around an encoder layer and aligns that layer to generic concepts, an autoregressive surrogate and hour-of-day, and shows forecasting accuracy does not suffer. We reuse its leak-free bottleneck design. We differ in three ways: we use domain concepts with simulator-supplied labels, we pretrain on synthetic data rather than using it as a sine-wave sanity check, and we ask whether the bottleneck localizes transfer failure, a question that paper does not pose.

Probabilistic Concept Bottleneck Models gives each concept a Gaussian, so a concept carries its own uncertainty. We use this only for the behavior group, because occupant actions are stochastic and the variance of a behavior concept is a natural signal for when to ask for real data. Applying it to all concepts would also run into the memory overhead that paper reports.

WattScale splits daily meter data into baseload, heating slope, cooling slope and balance points using Bayesian piecewise regression. It plays two roles here. It motivates the work, by showing a physics/behavior split is diagnostically valuable: it reports 95% agreement with professional audits. It also supplies the method for our real-data reference labels. We run its decomposition on real homes to obtain the physics-concept values the bottleneck should reproduce. Unlike WattScale, our model forecasts at hourly resolution and is pretrained at scale.

Two works shape the evaluation design. Improving Prediction Accuracy in Building Performance Models Using GANs blends a building model with synthetic occupant data and reduces lighting-control error. It is opaque and is never checked against real meters, and it is the kind of result our concept-level evaluation is meant to audit. The tracking study shows behavioral complexity matters more than visual fidelity. It constrains our design: we have to test whether richer simulated behavior alone closes the gap, without any bottleneck.

Research Program

The model is a Transformer encoder over load history and weather. A no-bypass bottleneck splits it into a physics group and a behavior group. The physics group holds effective thermal resistance, heat capacity, heating and cooling balance points, and solar gain response. The behavior group holds hourly occupancy fraction, heating and cooling setpoint offset, and plug-and-lighting intensity, each represented probabilistically. A shallow, monotone, hour-indexed decoder maps the concepts to the next-day load. Training is joint: forecast loss plus concept losses against EnergyPlus ground truth.

Concept labels come from the EnergyPlus model inputs behind Buildings-900K. If the released data do not expose the schedules, we re-simulate a stratified subset of about 50,000 residential and 20,000 commercial models with logged schedules.

Real-data checks use two sources of reference labels. WattScale-style decomposition supplies physics labels for all BuildingsBench homes that have weather data. The Dataport Austin homes, with appliance-level submetering (WattScale), supply direct measurements of HVAC and plug load, and so serve as partial ground truth for the behavior concepts.

The adaptation step freezes everything except the behavior encoder and fits it to the target home's first $n$ real days, with $n$ swept from 7 to 180. The exchange rate for a concept group is the number of real hours that a from-scratch model needs to match the zero-shot or adapted error of the synthetic-pretrained model. We compute it separately for commercial and residential buildings, and separately for physics-only and behavior-only adaptation.

Baselines

The naive reference is the BuildingsBench persistence ensemble, the seven-day average, on residential buildings, and previous-day persistence on commercial ones. It is the baseline that currently wins on homes, so any proposal that does not beat it there has failed. On commercial buildings the reported median NRMSE for previous-day persistence is 16.96% (BuildingsBench). For residential buildings we found no reported NRMSE on Lacuna, so we will recompute persistence on the same splits.

The strongest existing method is the BuildingsBench Transformer-L with a Gaussian output head. It reports a median zero-shot NRMSE of 13.31% on real commercial buildings. Fine-tuned on six months of data, a Transformer-M reaches a 98% probability of improvement over training from scratch (BuildingsBench). We will retrain it on exactly the same synthetic subset and token budget as our model, fine-tune it with the same real-day budgets $n$, and tune its learning rate with the same number of trials. Beating it means one of two things on residential buildings: lower median NRMSE at matched $n$, or matched NRMSE with substantially fewer real days. On commercial buildings we need to stay within about half a point of its NRMSE, which tests the "no accuracy penalty" claim.

The key ablations isolate the bottleneck. The first is the same architecture with the concept losses removed, an unsupervised bottleneck of equal width. The second keeps the concept losses but restores a residual bypass, which lets us measure leakage. The third adapts the physics group only, rather than the behavior group. A fourth arm adds domain randomization: we re-simulate with noisier occupant schedules and train the black-box Transformer on them, with no bottleneck.

Why not just…?

Why not just fine-tune the black-box Transformer on each home? BuildingsBench shows this already helps, so it is a real competitor and not a straw man. Our claim is narrower than "fine-tuning fails." We claim that adapting only the behavior concepts reaches the same error with fewer real days, and that it says what was corrected. If full fine-tuning matches behavior-only adaptation at every $n$, the accuracy argument for the bottleneck collapses, and only the diagnostic contribution remains. We will report that outcome as such.

Why not just make the simulated occupants noisier? This is the most serious threat. The tracking study found that behavioral complexity in synthetic data drove transfer gains (On the Equivalency, Substitutability, and Flexibility of Synthetic Data). The domain-randomization arm tests it directly. If noisier schedules alone close the residential gap, that confirms our localization hypothesis by a different route, but it weakens the case for bottleneck adaptation. Even then, the bottleneck tells us which behavior concept to randomize, and we will test whether targeted randomization beats uniform noise.

Why not just run WattScale, or post-hoc attributions on the black box? WattScale is interpretable, but it works on daily data, cannot forecast hourly load, and its authors report it struggles on commercial buildings (WattScale). We use it as a reference label, not as a rival forecaster. Post-hoc attributions on the black box can show which inputs mattered, but they cannot say "the setpoint estimate is wrong." They also do not support intervention, which concept bottlenecks do: in Koh et al., fixing two concepts reduced error (Concept Bottleneck Models).

Proposed Experiments

We evaluate on the BuildingsBench real buildings across its seven datasets, with the Dataport Austin homes as a concept-validation subset. Metrics are median NRMSE overall, concept error against WattScale-derived and submetered references, and the exchange rate in real hours per concept group.

The first decisive check is localization. On residential buildings, physics-concept error against the WattScale references should be close to its commercial level, and behavior-concept error against the Dataport submeters should be markedly worse. Across homes, behavior-concept discrepancy should predict forecast error, measured by Spearman rank correlation, better than physics discrepancy does. If physics error is equally bad, the "clean schedules" explanation is refuted.

The second check is adaptation efficiency. We compare behavior-only adaptation, physics-only adaptation and full fine-tuning across real-day budgets $n$. Success means behavior-only adaptation dominates physics-only adaptation and matches full fine-tuning at small $n$.

The third check is intervention. On Dataport homes, we replace the predicted plug-load and HVAC concepts with their submetered values and measure the drop in error. This tests whether the forecast actually depends on the concepts or bypasses them, and the no-bypass ablation should show the contrast.

The fourth check is the exchange-rate table: the real-hours equivalent of synthetic pretraining for commercial versus residential buildings, broken down by concept group. This would be the first such measurement for synthetic time series of human energy behavior.