NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Where Radiologists Disagree: Additive Decomposition of Inter-Observer Variability

When four radiologists rate the same lung nodule on a 1-to-5 malignancy scale and give it a 2, a 3, a 4 and a 4, the disagreement can come from three different places. They may have seen different things: one reader calls the margin spiculated and another calls it smooth. They may have weighed the same findings differently: both see moderate spiculation, but only one treats it as alarming. Or they may simply draw the line in different places: they agree on how suspicious the nodule is but map that suspicion onto the scale with stricter or looser cut-offs. Current methods for modeling reader disagreement learn a hidden "rater style" vector or train one deep network per reader. They reproduce the spread of opinions well, but they cannot say which of these three sources produced it, or which feature, at which value, it came from.

We propose to fit this decomposition directly with a generalized additive model (GAM). A GAM is a regression in which each input feature adds its own learned curve to the prediction, so every feature's effect can be plotted and read. The target is each individual reader's ordinal malignancy score, and the inputs are the morphological features that the same reader recorded. The LIDC-IDRI lung CT dataset makes this possible because every reading records both the malignancy score and that reader's own ratings of features such as spiculation, lobulation, margin, texture and calcification. Separating perception from integration from thresholding turns inter-observer variability from a nuisance into something measurable. It tells a training program whether readers need to learn to see differently or to decide differently. It also tells a dataset curator whether a "pessimistic" label reflects a biased cut-off or a real ambiguity in the image.

Core Claim

The claim is that reader disagreement on LIDC-IDRI malignancy scores can be split, with calibrated held-out likelihood, into four additive parts. The first is perception: variance across readings of the same nodule in the reader-reported features. The second is integration: reader-type-specific deviations in the curves that map features to suspicion. The third is thresholding: reader-type-specific shifts in the cut-points of the ordinal scale. The fourth is case ambiguity: a case-specific noise scale that is itself an additive function of the features. We further claim that the feature-to-suspicion curves are nonlinear in ways that matter clinically, and that comparing the shared radiologist curves against a curve fit to pathology-verified outcomes localizes the "safety-first" over-calling reported by Re-thinking and Re-labeling LIDC-IDRI for Robust Pulmonary Cancer Prediction to specific features and value ranges.

Written out for reading $r$ of nodule $n$ with ordinal score $y_{nr}$, reported features $c_{nrj}$, and latent reader type $m$, the model is

$$P(y_{nr} \le k) = \sigma\!\left(\frac{\theta_k + \tau_{m,k} - \sum_j \big[f_j(c_{nrj}) + g_{j,m}(c_{nrj})\big]}{s(c_{nr})}\right),$$

where $\sigma$ is the logistic function and $\theta_k$ are shared cut-points. The terms $\tau_{m,k}$ are type-specific cut-point shifts (the threshold component), $f_j$ are shared shape curves, and $g_{j,m}$ are penalized type-specific curve deviations (the integration component). The scale $s(c) = \exp(\sum_j h_j(c_j))$ is an additive model of how intrinsically hard a case is. Perception enters through the fact that $c_{nrj}$ differs across readings of the same nodule. Its contribution is the within-nodule variance of $\sum_j f_j(c_{nrj})$.

Relation to Prior Work

Three lines of work motivate the proposal by showing that disagreement carries signal. The Latent Doctor Model for Modeling Inter-Observer Variability uses a conditional variational autoencoder, with reader embeddings learned from sets of each reader's past labels, to sample individual diagnoses. The virtual expert panel of More is more trains one attention-based model per pathologist and ensembles them. Multi-rater Prism jointly calibrates a segmentation and the confidence assigned to each rater. All three reproduce the distribution of opinions. None separates why readers diverge, because the reader differences live in latent vectors or network weights. Our model gives up raw image input at the scoring stage in exchange for that separation.

Two lines of work supply the method. Concept bottleneck models (Concept Bottleneck Models; Robust and Interpretable Medical Image Classifiers via Concept Bottleneck Models) route predictions through human-named features, with a linear or MLP head and a single consensus label. We keep the concept route, replace the head with per-type additive curves, and fit to individual readings rather than to the consensus. NODE-GAM shows that differentiable additive models train with minibatch gradients and scale on the GPU, but it only fit hard labels. We use a spline-penalized version for the small primary study, and a NODE-GAM-style version when the mixture over reader types and the image-derived features make spline fitting awkward. Pathologist-like explainable AI for interpretable Gleason grading trains a concept-level segmentation model on soft labels from 54 pathologists. It does not model how each pathologist turns sub-pattern amounts into a grade, and that mapping is exactly what our model estimates.

One paper constrains the proposal. Re-thinking and Re-labeling LIDC-IDRI treats radiologist scores as biased and replaces them with labels propagated from biopsy-verified nodules. That seems to contradict the "disagreement is signal" line. Our model reconciles the two views by keeping both targets: pathology fits the shared curve, and radiologist readings fit the deviation from it. R2MNet binarizes the averaged LIDC scores and discards the variance we study.

Research Program

The primary study uses LIDC-IDRI readings. The inputs are reader-reported ordinal features plus nodule diameter derived from each reader's own outline. Diameter is continuous, so it is the most natural target for a smooth curve.

We anticipate a known practical problem: reader identities in LIDC are not reliably linked across scans. For that reason the reader type $m$ is a latent class, a small mixture fit by expectation-maximization over readings, rather than a named radiologist. This turns "rater-specific curves" into "reader archetypes," which is weaker but honest. The number of archetypes is chosen by held-out likelihood.

To test persistent individual readers, the secondary study uses the GleasonXAI multi-pathologist data. There the features are each pathologist's annotated area fractions of sub-patterns, and the target is that pathologist's Gleason pattern call. The same model is fit with named pathologists in place of latent types.

The third stage replaces reader-reported features with features predicted from the images. We train a concept extractor on LIDC to predict the distribution of reader feature ratings, not their mean. This lets the perception component be estimated for nodules that no reader rated, including the pathology-verified SCH-LND nodules. The same predicted features then anchor a pathology-fit curve, which we compare against the radiologist curves.

Baselines

The naive reference is majority-vote or mean-score regression. An ordinal regression on the consensus score has no reader or case terms, so it attributes all disagreement to irreducible noise. It is also the setting in which More is more reports a consensus model at ECE 0.183 against 0.050 for the full per-rater panel on DEPP. We expect a similar gap in calibration against individual readings.

The strongest distributional competitor is the Latent Doctor Model, which reports KL divergence 0.461 on Gleason2019 and entropy Spearman up to 0.728 on ISUP (The Latent Doctor Model). We run it on exactly the same LIDC nodule splits and the GleasonXAI splits. It receives the image crop plus the reader-reported features, so it has strictly more information than our model, and it gets a matched hyperparameter search budget. No reported result was found on Lacuna for per-reading ordinal likelihood on LIDC. The comparison is therefore run fresh, and it is scored on held-out negative log-likelihood of individual readings and on KL divergence to each nodule's empirical score distribution. Our model "beats" it if its likelihood is within the fold-to-fold standard error of the Latent Doctor Model's while also providing the decomposition. Being strictly better is not required, because the contribution is the decomposition, not raw fit.

The key ablation is a linear ordinal mixed model with the identical structure: latent reader types, cut-point shifts and case scale, but with linear feature effects. This isolates the additive-curve ingredient. A second ablation removes $\tau$ or $g$ in turn to check that each component is identifiable rather than absorbing the other.

For the pathology comparison, the reference point is the re-labeling result of Re-thinking and Re-labeling LIDC-IDRI: sensitivity 0.97 and specificity 0.23 with original labels, and 0.67 and 0.66 after re-labeling. Our aim here is not to exceed those numbers. It is to explain them by showing which curve deviations produce the specificity loss.

Why not just…?

Why not just use a linear mixed-effects ordinal model with rater random slopes? This is the real threat. If feature effects on LIDC are close to linear on the logit scale, the additive curves add parameters without insight. The linear ablation above settles the question. If the curves do not improve held-out likelihood, or if the fitted curves have effective degrees of freedom near one, we will report the decomposition with the linear model and drop the nonlinearity claim. We keep the GAM as the default because diameter-driven risk is widely expected to be thresholded, and because cancellation of opposing slopes is exactly the failure described for linear fits to U-shaped relations in the GAM literature (Nonlinear Association Between Serum Uric Acid and Femoral Neck BMD). Those expectations are not evidence for LIDC, though, and the experiment decides.

Why not just compute kappa statistics or fit a rater confusion-matrix model? Agreement statistics and per-rater confusion matrices quantify how much readers disagree and in which score categories. They cannot distinguish a reader who sees more spiculation from one who penalizes spiculation more. That distinction is only available because we condition on each reader's own feature reports. We will still report a confusion-matrix fit as a descriptive check that the threshold component recovers the same per-type bias pattern.

Why not train a black-box per-reader model and explain it with SHAP or saliency? Post-hoc attributions on a model like the virtual panel explain one network's prediction. They do not give a statistically separated perception-versus-integration split, and they offer no test-time intervention on named features. Concept Bottleneck Models found that intervening on two concepts cut task error from above 0.4 to about 0.3 on OAI, a capability post-hoc saliency does not provide. We also include this comparison directly. If SHAP curves from the Latent Doctor Model reproduce our fitted $g_{j,m}$ curves, the black-box route is sufficient and our structural claim weakens.

Proposed Experiments

The first decisive check is identifiability by simulation. We generate synthetic readings on real LIDC feature vectors with planted threshold shifts, planted curve deviations and planted perception noise, at the observed number of readings per nodule. We then require the fitted model to recover each component's share of variance to within a stated tolerance before any real-data claim is made. If thresholding and integration trade off against each other in the fit, the claim fails, and we collapse them into one component.

The second check is held-out fit on LIDC and GleasonXAI against the baselines above, using per-reading negative log-likelihood, ECE and nodule-level KL divergence. Splits are made by patient.

The third check is the pathology anchor. Using image-predicted features on SCH-LND and on the pathology-confirmed subset of LIDC, we fit the pathology curve and compare it with the shared radiologist curves. We then test whether the radiologist excess is concentrated where the prior re-labeling work says it should be. The prediction is that intermediate-suspicion nodules, which readers score as 3 and 4, sit where the radiologist curves are shifted upward relative to pathology, and that the shift appears mainly in the cut-point terms rather than in the curves. The opposite result, with the shift in the curves rather than the cut-points, would be equally informative: it would say that over-calling comes from how particular features are weighed, not from a global conservative bias.

The fourth check tests stability of the reader archetypes across bootstrap resamples. With named pathologists on GleasonXAI, we additionally test whether each pathologist's fitted threshold shift predicts their calls on held-out cores better than their overall agreement rate does.