Medical imaging models that look excellent inside the hospital where they were built often lose much of their accuracy at a new hospital. This is especially true for MRI, where the pixel intensities have no fixed physical units. Almost every brain MRI pipeline begins with spatial normalization: each scan is warped onto a shared reference brain, called a template or atlas, so that the same voxel refers to roughly the same anatomy in every subject. Teams generally assume this step helps models carry over to other sites. Nobody has measured how much it actually helps. The shift between hospitals has at least three parts: differences in head shape and scan geometry, differences in image appearance caused by scanner hardware and settings, and differences in which patients get scanned. Spatial normalization can only address the first.
We propose a controlled study with two parts. The first is a "transplant" test. We take held-out scans from the training cohort and give them one component of the external site's shift at a time: its leftover misalignment, its intensity profile, or its patient mix. The model stays frozen, and we measure how much each component alone costs in accuracy. The second part varies how aggressive the normalization is, from none to affine to deformable, and asks whether the gains track the geometric share of the drop. Everything is run under locked external validation, with templates built only from training data. The outcome tells practitioners which lever to pull: better registration, intensity harmonization, or local recalibration.
Core Claim
We hypothesize that for structural-MRI Alzheimer's classification transferred from ADNI to NACC, most of the external drop is appearance and population shift, not geometry. Once affine alignment is done, deformable registration and coordinate-locked architectures should add little transportability and may even hurt it. The transplant test is what is new. Prior work either ablated nothing or ablated normalization only within a single dataset. None of it split an observed external drop into parts that could be traced to specific preprocessing choices.
The decomposition can be written as follows. Let $A$ be the model's area under the ROC curve (AUC) on held-out ADNI scans, and $A_{ext}$ its AUC on NACC. The observed drop $\Delta = A - A_{ext}$ is compared with three transplant drops: $\Delta_{geo}$ from residual misalignment, $\Delta_{app}$ from intensity transfer, and $\Delta_{pop}$ from reweighting to NACC's demographic and diagnostic mix. The quantity of interest is
$$\Delta = \Delta_{geo} + \Delta_{app} + \Delta_{pop} + \Delta_{int} + \Delta_{res},$$
where $\Delta_{int}$ is the extra drop when all three transplants are applied jointly, beyond the sum of the single drops. $\Delta_{res}$ is whatever real NACC scans cost beyond the joint transplant, such as label noise, protocol artifacts, or motion.
Grounding in Prior Work
Two papers motivate the study by exposing the gap. Development of a Deep Learning Model for Early Alzheimer's Disease Detection from Structural MRIs and External Validation on an Independent Cohort trains a 3D convolutional network with instance normalization on about 2,600 ADNI scans. Its preprocessing includes affine alignment to an average brain. It reports an AUC of 85.12 on about 2,000 heterogeneous NACC scans, but it never ablates the alignment step. The Impact of Scanner Domain Shift on Deep Learning Performance in Medical Imaging: an Experimental Study shows that MRI is the modality most sensitive to scanner changes (mean ΔAUC −0.097, and prostate MRI collapsing from 0.791 to 0.505). It studies only image-level learning, however, and never asks whether registration moves the number. We supply the missing ablation and the attribution.
Three papers supply methods we reuse and also constrain our expectations. Few-shot image segmentation for cross-institution male pelvic organs using registration-assisted prototypical learning finds that removing an affine alignment module costs at least 12% in some cross-institution tests. That is evidence geometry can matter, but it comes from segmentation with few labels, where boundaries are inherently geometric. We test whether the effect survives in whole-brain classification. Atlas-ISTN jointly learns an atlas and a diffeomorphic warp, meaning a smooth, invertible deformation. It refines the warp for about 20 seconds per external subject and beats VoxelMorph across UK Biobank, Cam-CAN and IXI. We use its test-time refinement as the strongest geometric arm.
Harnessing spatial MRI normalization: patch individual filter layers for CNNs introduces patch-individual filter (PIF) layers, which assign separate convolution kernels to each region of the normalized brain. PIF helps in low-data and focal-lesion settings. On ADNI, though, PIF slightly underperformed an ordinary network, and it was only ever evaluated within a single dataset. That within-dataset result partly cuts against any "more spatial prior is better" story. We treat it as a prediction to test externally: kernels locked to coordinates should be the architecture most exposed to residual misalignment at external sites.
Two papers set the validation rules. Rescaling and other forms of unsupervised preprocessing introduce bias into cross-validation shows that fitting unsupervised preprocessing on pooled data biases performance estimates. We therefore build every study-specific template and every intensity reference from ADNI training folds only. We also add one deliberately leaky arm that builds the template from pooled ADNI and NACC data, to size that bias. All models are local argues that static external validation is not enough and that local recalibration is often necessary. We accept that framing. Our results are meant to show which part of the drop recalibration can fix and which part must be fixed upstream.
Research Program
The main task is three-way classification of cognitively normal, mild cognitive impairment (MCI) and Alzheimer's disease (AD). We train on ADNI and evaluate on NACC. Weights, hyperparameters and decision thresholds are locked before any NACC scan is opened. The backbone replicates the 3D network of the Alzheimer's detection study as closely as its description allows.
We vary normalization depth in four steps. The first applies only brain extraction and reorientation to a standard axis convention (right-anterior-superior, as in Amber L. Simpson et al.). The second adds rigid alignment. The third uses affine alignment to a template built from ADNI training folds. The fourth adds deformable registration to the same template. A fifth arm adds Atlas-ISTN-style test-time refinement on top of deformable registration.
For the transplant test, we first estimate each scan's residual misalignment. After a given normalization depth, we run a fine deformable registration of the output to the template and keep that residual displacement field. We gather these residual fields separately from NACC sites and from held-out ADNI scans. The geometry transplant applies NACC residual fields to held-out ADNI scans and measures the drop against applying ADNI residuals, the matched control. The appearance transplant maps held-out ADNI intensities onto site-specific NACC intensity histograms and bias-field profiles. The population transplant reweights held-out ADNI scans to match NACC's distribution of age, sex and diagnosis. Each transplant is run at every normalization depth. The key prediction is that $\Delta_{geo}$ shrinks as normalization deepens while $\Delta_{app}$ stays flat.
A secondary task checks that the finding generalizes beyond one disease: brain-age regression using the pretrained lightweight network (SFCN) from Accurate brain age prediction with lightweight deep neural networks, with its public weights in UKBiobank_deep_pretrain. We train on UK Biobank and evaluate on Cam-CAN and IXI. This task probes a diffuse, whole-brain signal, which PIF theory predicts is least helped by coordinate locking.
Baselines
The naive reference point is the first depth arm: brain extraction and reorientation only, with no template alignment. It measures how much any normalization buys at all. If a skull-stripped, reoriented model with instance normalization already reaches the affine pipeline's NACC score, registration is not doing the transportability work.
The strongest existing method is the affine-aligned 3D network of Development of a Deep Learning Model for Early Alzheimer's Disease Detection from Structural MRIs and External Validation on an Independent Cohort, which reports an external NACC AUC of 85.12. We reimplement it, and first check that our reimplementation lands near that number. All arms then share the same data splits, the same training budget in GPU-hours, and the same number of hyperparameter trials tuned on ADNI validation folds only.
We add four further comparisons. The first is the FreeSurfer regional-volume gradient-boosting baseline from the same paper, which heavily uses atlas propagation but is slow, at about 11.2 hours per scan. The second is Atlas-ISTN-style test-time refinement, the strongest purely geometric intervention. The third is intensity harmonization without deformable registration, using the multi-center harmonization code in PLHN fitted on training sites only. The fourth is a reference that mixes in target-site data, following the finding in the scanner-shift study that 10–20% target data recovers most of the loss. This last arm is an upper bound, not a competitor.
The ablation that isolates our key question is deformable versus affine at fixed architecture, repeated with and without PIF layers. For brain age, no reported result was found on Lacuna for Cam-CAN or IXI external MAE with SFCN. Within UK Biobank the model reports a test mean absolute error (MAE) of 2.14±0.05 years, and that within-cohort figure is our in-distribution anchor.
A deeper normalization arm "beats" affine only if its NACC AUC gain has a site-stratified bootstrap 95% confidence interval that excludes zero. It must also not worsen calibration error at the locked threshold.
Why not just…?
Why not just use aggressive spatial augmentation instead of registration? This is a real threat. The evidence against augmentation in the file concerns Gaussian noise, which the scanner-shift study found degraded performance. That is not geometric augmentation. We therefore include random affine and elastic augmentation as an arm with no registration, trained under the same budget. If it matches the affine arm on NACC, the practical conclusion is that registration is optional for classification. We would report that conclusion as the result rather than hedge it.
Why not just harmonize intensities, since MRI shift is mostly appearance? That is our own hypothesis. The study exists to test it rather than assume it. The appearance transplant sizes how much harmonization could recover at most. The harmonization arm then shows how much a real method achieves. If geometry turns out to carry a large $\Delta_{geo}$ even after affine alignment, harmonization alone would leave that gap open.
Why not just mix in or fine-tune on target-site data? The scanner-shift study shows that this works, and All models are local makes the operational case for it. Its cost is governance. Simon K. B. Spohn et al. found that only 77 of 251 prostate radiomics studies obtained validation cohorts at all. We include target mixing as an upper bound and report what fraction of its recovery comes free, without target labels, from each normalization depth.
Why not just use FreeSurfer regional volumes? They are already shown to transfer worse to NACC than the affine network, and they are about 11.2 hours per scan. We keep them to check that our reimplementation reproduces that ordering.
Decisive Checks
Three results would settle the question. First, if $\Delta_{geo}$ after affine alignment is under one AUC point, and deformable registration gains nothing over affine on NACC, then spatial normalization beyond affine is not a transportability lever for this task. Second, if PIF loses more AUC externally than the ordinary network, with its loss growing with measured residual misalignment across NACC sites, then coordinate-locked filters are shown to be externally fragile. Third, if the leaky pooled-template arm inflates NACC AUC relative to the training-only template, that quantifies a validation error that current pipelines can silently commit.
Across all arms we report per-site AUC, calibration error at the locked threshold, and the correlation between each site's median residual-field magnitude and its AUC drop. The last of these tests whether registration quality, which needs no labels, can flag risky deployment sites in advance.
References
- Development of a Deep Learning Model for Early Alzheimer’s Disease Detection from Structural MRIs and External Validation on an Independent Cohort
- The Impact of Scanner Domain Shift on Deep Learning Performance in Medical Imaging: an Experimental Study
- FEW-SHOT Image Segmentation for Cross-Institution Male Pelvic Organs Using Registration-Assisted Prototypical Learning
- Atlas-ISTN: Joint segmentation, registration and atlas construction with image-and-spatial transformer networks
- Harnessing spatial MRI normalization: patch individual filter layers for CNNs
- Rescaling and other forms of unsupervised preprocessing introduce bias into cross-validation
- All models are local: time to replace external validation with recurrent local validation
- A large annotated medical image dataset for the development and evaluation of segmentation algorithms
- Accurate brain age prediction with lightweight deep neural networks
- Radiomics in prostate cancer imaging for a personalized treatment approach - current aspects of methodology and a systematic review on validated studies