Generative models of brain MRI are increasingly used to impute missing scans, augment small cohorts, and produce "what-if" images of a patient with lesions removed. Many of these generators are trained adversarially: a generator network produces images, and a second network, the discriminator, tries to tell them apart from real ones. Such training is unstable, and the standard remedies all blur what the discriminator can see. Blurring the discriminator's inputs with noise, penalizing how sharply its output changes with the image, or passing images through a noising chain all make it deliberately short-sighted. This proposal argues that the short-sightedness has a specific cost in multiple sclerosis (MS). The clinico-radiological paradox is the observation that visible lesion load explains disability poorly. The damage that does predict disability is largely subtle and diffuse: small intensity shifts in white matter that looks normal on the scan. A discriminator made blind to small differences cannot penalize a generator for leaving those shifts out. Stabilized generators may therefore reproduce the obvious lesions faithfully while quietly "healing" the invisible pathology that matters most clinically.
The core claim is testable and has two parts. First, the rate at which a stabilized generator reproduces a tissue difference falls off predictably as the difference shrinks relative to the stabilization's effective smoothing scale. Lesions survive. Microstructural shifts in normal-appearing white matter (NAWM) do not. Second, the loss can be repaired without giving up stability. The clinically relevant signal lives in a low-dimensional summary: mean quantitative values per white-matter tract. In that small space the two distributions overlap, and the vanishing-gradient pathology that motivates heavy smoothing does not apply. A second, lightly regularized discriminator operating on tract statistics can therefore enforce fidelity where the image-level discriminator cannot.
Why this gap is real
The stabilization literature supplies the mechanism. Towards Principled Methods for Training Generative Adversarial Networks proved that when real and generated images lie on non-overlapping low-dimensional surfaces, an optimal discriminator gives zero gradient almost everywhere. It proposed adding noise to both distributions so their supports overlap. Stabilizing Training of Generative Adversarial Networks through Regularization replaced explicit noise with its Taylor approximation, a penalty $\frac{\sigma^2}{2}\mathbb{E}\|\nabla_x D(x)\|^2$ on the discriminator's input gradient. Here $D$ is the discriminator and $\sigma$ is the noise scale being mimicked. The equivalence matters because it puts noise injection and gradient penalties on one axis, an effective smoothing scale $\sigma$. On Stabilizing Generative Adversarial Training With Noise and Diffusion-GAN: Training GANs with Diffusion prove that mixing clean and noised views, or using an invertible noising chain, still leaves the true distribution as the global optimum. These are statements about the optimum. They say nothing about how strong the gradient toward a small discrepancy is under finite data and capacity. That is the regime a 2D-to-3D medical generator actually trains in.
The clinical literature supplies the stakes. Tract-wise microstructural analysis informs on current and future disability in early multiple sclerosis computed quantitative T1 z-scores across 37 atlas tracts. Those NAWM z-scores predicted two-year disability progression better than total lesion volume, with infratentorial tracts carrying the prognostic signal. Texture and radiomics work (Texture Analysis of MR Images of Minocycline Treated MS Patients; Developments in MRI radiomics research for vascular cognitive impairment) likewise locates predictive information in low-amplitude parenchymal changes. The damage that explains the paradox is thus exactly the kind of signal a short-sighted discriminator is built to ignore.
The one paper bridging generation and the paradox, A Structural Causal Model for MR Images of Multiple Sclerosis, uses a hierarchical variational autoencoder on 2D slices. It erases lesions convincingly but cannot add them, and it validates counterfactuals only by checking that a segmentation network finds no lesions afterward. The obvious next step is to swap in a stabilized adversarial or diffusion backbone. We do not propose that. We propose to ask what any such backbone must preserve for its images to be clinically meaningful, and to measure whether stabilization destroys it. Reinhold et al.'s lesion-count check would pass a generator that had flattened every NAWM tract to healthy values. Our evaluation is designed to catch exactly that failure.
Core Claim and Prediction
Consider a tract whose voxels carry a mean intensity shift $\delta$ over voxel-level variability $s$. Blurring with noise of scale $\sigma$ lowers the per-voxel separability of shifted and unshifted tissue to roughly $\delta^2/(s^2+\sigma^2)$, the KL divergence between two equal-variance Gaussians differing in mean by $\delta$. A patch-based convolutional discriminator with a bounded input gradient cannot recover the missing strength by pooling across the thousands of voxels in a tract. A discriminator that sees the tract mean directly gains a factor of roughly the tract's voxel count $N$.
We therefore predict three things. The fraction of an injected shift that a generator reproduces should be a decreasing function of $\sigma/\delta$ alone, collapsing curves across different stabilizers once each is converted to its effective $\sigma$. Lesion contrast, where $\delta \gg \sigma$, should be preserved at every setting. A tract-statistic discriminator should flatten the curve without raising the divergence rate. If the curves do not collapse, or if lightly stabilized image discriminators already recover small shifts, the claim is wrong.
Research Program
The work has three stages.
The first stage is a controlled injection study, where ground truth is known. We take real MRI volumes from the ISBI 2015 longitudinal MS challenge (Carass et al.) and MSSEG-2 (Basaran et al.) and register a white-matter tract atlas to each. In a random subset of subjects, we multiply NAWM intensities in chosen tracts by a smooth field whose amplitude $\delta$ ranges from a fraction of a percent to lesion-like contrast. Existing lesions are kept as the large-$\delta$ reference. Because we control which subjects carry which shifts, the true joint distribution of tract shifts is known exactly.
The second stage is a stabilization sweep. We train generators under R1 penalties at several strengths, instance noise at several scales with and without annealing, the clean-plus-filtered mixture of Jenni and Favaro, and Diffusion-GAN with its adaptive noising schedule. Each stabilizer is mapped to an effective $\sigma$ through the Roth et al. equivalence, or through the discriminator's measured input-gradient norm where no analytic map exists. We run 2D axial slices at the Reinhold et al. resolution first, then 3D patches centered on infratentorial tracts, because the file notes that 3D noise schedules are unverified.
The third stage adds the remedy. A second discriminator receives the vector of per-tract mean and variance of intensity, computed by differentiable masked pooling on the generated volume under the registered atlas. The image-level discriminator keeps its stabilization. The tract-level discriminator receives only a weak gradient penalty, since its low-dimensional inputs overlap and it does not face the manifold-mismatch problem.
If access can be arranged, a final validation moves to a cohort with quantitative T1 and disability scores of the kind used by Ravano et al. The question there is whether the association between synthetic NAWM z-scores and disability matches the real association. We note plainly that no such dataset appears in the file as public.
Baselines
The naive reference is the real data itself, together with an unstabilized non-saturating GAN. Real volumes set the ceiling for every fidelity metric. The unstabilized GAN shows what stability costs: we expect it to diverge or mode-collapse often, consistent with the toy-task finding in Roth et al. that unregularized training collapsed around 50,000 iterations while regularized training continued past 100,000. The same architectures, data splits, and iteration budgets are used for every model.
The strongest existing stabilized adversarial method is Diffusion-GAN. It reports FID 2.83 against StyleGAN2's 4.41 on FFHQ at 1024 pixels, and 63.34 against 102.58 in the 200-image regime, which is the closest analogue to small MS cohorts. It is the strongest competitor because its adaptive schedule is designed to avoid over-smoothing, so it is the most likely to already recover small shifts. We run it with its published adaptive schedule, and with an equal tuning budget over its target overfitting ratio. We found no reported result on Lacuna for generative fidelity of any method on ISBI 2015 or MSSEG-2. Every number in this study will therefore be produced here.
The strongest non-adversarial competitor is a plain denoising diffusion model trained by score matching. We also train its equivariantly adversarial variant from Why Adversarially Train Diffusion Models?, which smooths the learned score field and may itself flatten small shifts. For a fair comparison, both receive matched compute. We note the roughly 2.5x training overhead that paper reports for the adversarial variant.
The ablation isolating our key ingredient replaces the tract-level discriminator with a direct moment-matching loss on the same tract statistics. This tells us whether adversarial pressure is needed there at all.
Beating the baselines means two things at once. The remedy must restore the reproduced shift fraction to within the sampling error of real data for shifts at or below the smallest injected amplitude where Diffusion-GAN loses more than half the shift. It must also match that model's divergence rate and its lesion segmentation performance.
Why not just…?
Why not just lower the gradient penalty until small shifts come back? Roth et al. show that weak regularization lets architectures without normalization fail outright, and annealing noise toward zero is reported to reintroduce divergence late in training. Our sweep traces the stability-versus-fidelity frontier explicitly. If some penalty strength achieves both stable training and full shift recovery, the remedy is unnecessary, and that frontier plot is the experiment that would show it.
Why not just use a plain diffusion model and skip discriminators? This is the most serious threat. Score-matching models have no discriminator to blind, although their small-noise denoising and the smoothing effect described by Wang et al. could still attenuate small shifts. We treat the plain diffusion model as a first-class arm. If it reproduces small NAWM shifts faithfully, the practical conclusion becomes "avoid adversarial stabilizers for paradox-relevant MS synthesis." That is still a useful result, and it would narrow our claim to adversarial pipelines.
Why not just add a tract-mean regression loss instead of a second discriminator? Matching per-tract means is cheap and may suffice for first moments. It will not match the joint distribution of shifts across tracts or subjects, which carries the prognostic structure in Ravano et al. The moment-matching ablation settles this directly. We will report it as the preferred method if it ties.
Why not just skip generation and train classifiers on tract features? For prediction alone this is reasonable, though Evaluation of machine learning-based classification of clinical impairment and prediction of clinical worsening in multiple sclerosis found that tabular models reach AUC 0.83 for current disability yet fail to predict worsening significantly. Our question is different. It concerns whether generators already being used for counterfactuals and augmentation silently remove the relevant signal, and no classifier answers that.
Decisive Checks
The primary metric is the reproduced shift fraction. For each injected amplitude, we estimate the tract-wise shift in a large set of generated samples, conditioned on the injection label, and divide by the injected value. We plot this against $\sigma/\delta$ for every stabilizer. As a second measure, a classifier trained on real shifted versus unshifted tracts is applied to synthetic tracts; its detection rate should track the injected prevalence.
Lesion fidelity is measured by running a segmentation network on synthetic volumes and on real test volumes. Real-data references are the Dice of 0.61 reported for a multi-branch CNN on ISBI 2015 (Aslani et al.) and the Dice of 0.510 with $F_1$ 0.552 reported for nnU-Net with CarveMix on MSSEG-2. Stability is measured as the fraction of seeds that diverge or collapse.
The decisive result has three parts. Curves for different stabilizers should collapse onto a common function of $\sigma/\delta$. Lesion fidelity should stay flat across the sweep while NAWM fidelity drops. The tract-level discriminator should lift the small-shift end of the curve without increasing divergence. A final downstream check trains the Noteboom-style tract-feature classifier on synthetic-augmented data and tests on held-out real data, to see whether augmentation from each generator helps or hurts discrimination of shifted subjects.
References
- Towards Principled Methods for Training Generative Adversarial Networks
- Stabilizing Training of Generative Adversarial Networks through Regularization
- On Stabilizing Generative Adversarial Training with Noise
- Diffusion-GAN: Training GANs with Diffusion
- Tract-wise microstructural analysis informs on current and future disability in early multiple sclerosis
- Texture Analysis of MR Images of Minocycline Treated MS Patients
- Developments in MRI radiomics research for vascular cognitive impairment
- A Structural Causal Model for MR Images of Multiple Sclerosis
- Longitudinal multiple sclerosis lesion segmentation data resource
- New lesion segmentation for multiple sclerosis brain images with imaging and lesion-aware augmentation
- Why Adversarially Train Diffusion Models?
- Evaluation of machine learning-based classification of clinical impairment and prediction of clinical worsening in multiple sclerosis
- Multi-branch convolutional neural network for multiple sclerosis lesion segmentation