Using the Other Knee as a Control for Externally Valid Osteoarthritis Prognosis

Models that forecast knee osteoarthritis (OA, the gradual wearing-down of joint cartilage and bone) look strong inside the cohort they were built on and weak elsewhere. In the KNOAP2020 challenge, every team trained mainly on the Osteoarthritis Initiative (OAI) and was tested on an independent cohort of overweight women. The best entry reached a ROC AUC of only 0.636, and the best MRI-only entry reached 0.537 (KNOAP2020). A likely cause is shortcut learning: networks pick up scanner and protocol "signatures" of the site instead of disease (Asilian Bidgoli et al.). Most participants in these cohorts have both knees imaged, usually on the same scanner, at the same visit, under the same protocol. So most of the site signature is shared between a person's two knees. Disease that is driven by mechanics, meaning uneven loading of the inner (medial) versus outer (lateral) half of the joint, is often not shared. The challenge organizers treated paired knees as a nuisance "data bias." We propose to use the pair as a built-in control.

The core idea fits in two sentences. Predict whether a knee will progress from how each of its compartments differs from the same compartment in the person's other knee, after subtracting the left-right difference that the person's leg alignment would predict anyway. Shared site artifacts largely cancel in that comparison, while one-sided, mechanically driven damage survives it. We expect this to shrink the gap between internal and external performance, not just raise internal accuracy.

Core Claim

Our claim is about transfer, not about raw accuracy. For radiographic progression prediction, a model built on contralateral, compartment-matched, alignment-corrected differences will lose less discrimination when moved to a new site than a single-knee model of equal capacity. Site identity will also be harder to decode from its representation. The intuition can be written as a simple model. Suppose knee $k$'s compartment-$c$ features are $z_{k,c} = \mu_{k,c} + s + \epsilon_{k,c}$, where $\mu$ is the biological state, $s$ is a site/session offset shared by both knees of one visit, and $\epsilon$ is noise. Then the difference

$$d_c = z_{i,c} - z_{j,c} - g_c(a_i, a_j)$$

does not depend on $s$. Here $i$ is the index knee, $j$ the contralateral knee, $a$ the automatically measured alignment angles, and $g_c$ a learned prediction of the benign left-right difference those angles imply. The additive assumption is clearly too simple. Whether it holds well enough is exactly what the site-decodability experiments below test.

This uses the three directions in different roles. Bilateral comparison is the mechanism. The external validation gap is the target and the evaluation setting. Medial-lateral mechanical asymmetry is the constraint that shapes the design: compartments are compared like-for-like across limbs, and they are not forced to share one feature extractor. Prior compartment models flip the medial patch and pass it through the same weights as the lateral patch (Tiulpin et al.; Nguyen et al.). Physical and finite-element studies, however, show that the medial plateau carries higher contact pressure during sit-to-stand (Hanatani et al.), is about 1.2–1.3 times stiffer in healthy bone, and diverges further from the lateral side under bone loss (Zheng et al.). That evidence is from rats and physical replicas, so it motivates the untied design but does not prove it helps in human radiographs. We therefore treat it as an ablation, not an assumption.

Relation to Prior Work

Four groups of work bear on this proposal. The first group supplies the method. Bilateral comparison works in brain CT (Liu et al.), chest imaging with learned registration (Zhao et al.), cross-hemisphere attention (Liang and Han), and mammography counterfactuals built from the other breast (Wang et al.). All of these use the pair to make lesions stand out within one dataset. None tests whether pairing buys robustness to site shift, which is our question.

The second group constrains the design. Comparison against the other side fails when disease is bilateral and symmetric (Chen and Liu), and healthy pairs are not exact twins (Fineide et al.; Jin et al.). For these reasons we keep a narrow single-knee branch and model expected asymmetry from alignment, rather than subtracting raw images.

The third group defines the knee benchmarks. Progression models built on DESS MRI (a 3D cartilage-sensitive MRI sequence) and multimodal transformers treat each knee in isolation (Panfilov et al. 2022; Panfilov et al. 2023). Panfilov et al. 2023 also gives us a held-out-site protocol (OAI site D). The fourth group supplies the alignment inputs: automated landmark networks for knee alignment angles ( Deep Learning-Based Alignment Measurement in Knee Radiographs; Automatic measurement of lower limb alignment in portable devices based on deep learning for knee osteoarthritis; Automatic measurement of lower limb alignment in portable devices based on deep learning for knee osteoarthritis). Both papers state they were never externally validated, so we must check the alignment network's own transfer error.

Research Program

The work starts by measuring the problem. We build a strong single-knee radiograph progression model on OAI and record how much it drops on held-out OAI site D. We also train a linear probe on its features to predict acquisition site, which tells us how strongly the representation encodes the site.

The second step builds the pair model. A compartment encoder produces medial and lateral feature vectors for each knee. In the main variant, the medial and lateral encoders do not share weights, and the medial encoder is shared across left and right knees after mirroring the image so both knees face the same way. An alignment network estimates the anatomical tibiofemoral angle (the angle between thigh and shin bones on a standard front-view knee X-ray) for each knee, in the style of Deep Learning-Based Alignment Measurement in Knee Radiographs. A small network $g_c$, fit on stable pairs where neither knee progresses, predicts the expected compartment difference from the two alignments.

The progression head sees the alignment-corrected differences $d_c$. It also sees a deliberately low-dimensional summary of the index knee's absolute state, which keeps the model useful when both knees degrade together. We will sweep the size of that bottleneck and measure a tradeoff curve: wider absolute branches should raise internal AUC but bring back site decodability and the transfer gap. This tradeoff is a central result of the study.

We treat the "both knees progress" subgroup as a known weak spot and report it separately. We also report one-sided progression and medial-dominant versus lateral-dominant progression, where the latter is defined by compartment-level joint space narrowing.

Baselines

The naive reference is a clinical model: logistic regression on age, BMI, sex, baseline KL grade (the standard 0–4 Kellgren-Lawrence radiographic severity score), and automated alignment angles. Its value is that it has almost no image pathway through which site artifacts could enter, so it shows how much the images add at all. It is fit on the same OAI training subjects, and beating it means a significantly higher external AUC.

The main image competitor is a single-knee compartment model in the style of Tiulpin et al.: medial and lateral patches, the medial patch flipped, shared weights. We retrain it for progression with the same backbone, augmentation, and hyperparameter budget as our model. On grading rather than progression, this design reached AUC 0.93 for KL≥2 when trained on the Multicenter Osteoarthritis Study (MOST) and tested on OAI (Tiulpin et al.). The semi-supervised variant reached 0.933 from OAI to MOST (Nguyen et al.).

The strongest reported external number on true out-of-cohort progression is KNOAP2020's winning entry, ROC AUC 0.636 (95% CI 0.571–0.699), with best balanced accuracy 0.587 (KNOAP2020). If the organizers grant access to the PROOF test set, which we do not assume, beating it means a point estimate above 0.636 from a radiograph-plus-clinical model under the same protocol, including the 30-knee fine-tuning set. On the OAI site-D protocol, the reference is the multimodal transformer at AUC 0.70–0.76 across horizons (Panfilov et al. 2023). We will rerun a radiograph-only version of it on our splits rather than compare against those published numbers directly.

Ablations isolate each ingredient. The concatenation ablation feeds both knees' features side by side with no differencing; this is the key test of whether subtraction itself matters. A tied-weights ablation shares weights between medial and lateral encoders. A no-alignment ablation sets $g_c=0$. An unbottlenecked ablation gives the absolute branch full width. All variants use identical compute, the same number of tuning trials, and five seeds. We call a result a win when our model's internal-minus-external AUC gap is smaller than the single-knee model's, with a bootstrap confidence interval that excludes zero, and external AUC is no worse.

Why not just…?

Why not just concatenate both knees and let the network learn the comparison? This is the most serious threat. A flexible network given both knees could in principle learn to subtract the shared site offset. It could equally use the duplicated site signal as an even stronger shortcut. The concatenation ablation settles this directly. If it matches our model on both the transfer gap and site decodability, then explicit differencing adds nothing, and we would report that.

Why not just harmonize intensities or fine-tune on a few target knees? KNOAP2020 teams used extensive preprocessing and still landed between 0.501 and 0.636 AUC. Preprocessing choices alone can also swing results across sites (Van De Water et al.). We still run histogram matching plus 30-knee fine-tuning on the single-knee baseline, because if the difference model only matches this cheap fix, its value is limited to settings without target-site labels.

Why not just use alignment angles in a regression? These angles capture loading but not tissue state. KNOAP2020 suggests clinical variables alone plateau below image-plus-clinical models. The naive baseline above quantifies this on our splits. If it matches the image models externally, that is itself an important negative result about imaging.

Proposed Experiments

The main experiment trains on OAI, excluding site D, and predicts radiographic progression at several horizons. We test on site D, and on PROOF only if access is granted. As a secondary transfer check, we compare KL-grade discrimination between OAI and MOST, since the file reports no longitudinal MOST labels. We report ROC AUC, average precision, the internal-minus-external gap, and calibration.

The decisive mechanistic check is site decodability. A linear probe should predict OAI site markedly worse from $d_c$ than from single-knee features at matched internal AUC. In a controlled test, we apply synthetic scanner-like intensity and contrast transforms to both knees of held-out patients. The difference model's predictions should change less than the single-knee model's, while the same transforms applied to one knee only should affect both models.

The falsifying outcome is clear in advance. If the gap does not shrink, or if it shrinks only because external AUC rises in the bilateral-progression subgroup where the difference signal should be weakest, then the shared-offset hypothesis is wrong for knee radiographs. Finally, we audit the alignment network's own angle error on site D. If alignment error grows at the new site, $g_c$ could carry a new site shortcut into the model, so we must rule that out.

References

  1. The KNee OsteoArthritis Prediction (KNOAP2020) challenge: An image analysis challenge to predict incident symptomatic radiographic knee osteoarthritis from MRI and X-ray images
  2. Bias reduction in representation of histopathology images using deep feature selection
  3. Automatic knee osteoarthritis diagnosis from plain radiographs:a deep learning-based approach
  4. Semixup: In- and Out-of-Manifold Regularization for Deep Semi-Supervised Knee Osteoarthritis Severity Grading From Plain Radiographs
  5. Development of Stress Measurement System during Human Stand-up Motion Using Accurate Shape Knee Joint Model
  6. Medial tibial plateau sustaining higher physiological stress than the lateral plateau: based on 3D printing and finite element method
  7. Classification-Driven Pathological Neuroimage Retrieval Using Statistical Asymmetry Measures
  8. Contralaterally Enhanced Networks for Thoracic Disease Detection
  9. Symmetry-Enhanced Attention Network for Acute Ischemic Infarct Segmentation with Non-Contrast CT Images
  10. Bilateral Asymmetry Guided Counterfactual Generating Network for Mammogram Classification
  11. AsT: An Asymmetric-Sensitive Transformer for Osteonecrosis of the Femoral Head Detection (Student Abstract)
  12. Predicting an unstable tear film through artificial intelligence
  13. Interocular agreement and differences of ocular growth in cataract patients
  14. Predicting Knee Osteoarthritis Progression from Structural MRI Using Deep Learning
  15. End-To-End Prediction of Knee Osteoarthritis Progression With Multi-Modal Transformers
  16. Deep Learning-Based Alignment Measurement in Knee Radiographs
  17. Automatic measurement of lower limb alignment in portable devices based on deep learning for knee osteoarthritis
  18. Automatic measurement of lower limb alignment in portable devices based on deep learning for knee osteoarthritis
  19. Yet Another ICU Benchmark: A Flexible Multi-Center Framework for Clinical ML