Delta radiomics predicts treatment response from how a tumor's measured features change between a scan taken before therapy and one taken after it. The features are numbers such as texture, shape and intensity statistics computed inside the tumor outline. The change signal is biologically meaningful, but it has a weakness that current methods ignore. Patients are often rescanned at a different hospital, on a different scanner, or with thicker slices than at baseline. A delta feature can then measure the difference between machines rather than the difference in the tumor.
We propose to model this explicitly. The amount of acquisition noise in a delta feature depends on whether the two scans in a pair were acquired the same way, so we will train response models by injecting noise whose size depends on that match. We will then test whether the models keep their accuracy, and their advantage over radiologists, on the mismatched pairs that dominate external, multi-center use.
The motivating evidence is concrete. In the largest multi-center delta study in our file, Zheng et al. predicted pathologic complete response to neoadjuvant chemoimmunotherapy in lung cancer from pre- and post-treatment CT. Their area under the ROC curve (AUC) fell from 0.85 on internal test data to 0.78 on external data. Their most predictive features were changes in tumor sphericity and flatness. These 3D shape measures are exactly the ones that thick-slice reconstruction distorts, because shape computed from 5 mm slices loses through-plane detail. We read this as a single mechanism: delta features combine scanner drift with the loss of 3D shape information, and both are worst when baseline and follow-up acquisitions differ.
Core Claim
Acquisition noise in a delta feature is not the sum of the noise in two static features. Write an observed feature as true value plus noise, $f_t = x_t + e_t$ at time $t \in \{\text{pre}, \text{post}\}$, where $e_t$ has variance $\sigma_t^2$ and the two noise terms have correlation $\rho$. The relative delta used in the literature, $\Delta = (f_{\text{post}} - f_{\text{pre}})/f_{\text{pre}}$, then has noise variance of roughly
$$\mathrm{Var}(\Delta_{\text{noise}}) \approx \frac{\sigma_{\text{post}}^2 + r^2\sigma_{\text{pre}}^2 - 2r\rho\,\sigma_{\text{pre}}\sigma_{\text{post}}}{x_{\text{pre}}^2},$$
where $r = x_{\text{post}}/x_{\text{pre}}$. This form follows from a first-order Taylor expansion of the ratio. It makes two points:
- When both scans come from the same scanner and protocol, $\rho$ is high and much of the systematic error cancels.
- When the scans differ in vendor, kernel or slice thickness, $\rho$ is near zero, both variances add, and the result is divided by the baseline value. Small baseline values therefore amplify the noise.
A model trained mostly on matched pairs from one center learns to trust delta features that become unreliable on mismatched pairs elsewhere. We claim that training with pair-conditional noise lets the learner down-weight each delta feature in proportion to its reliability under the expected acquisition match. We expect this to shrink the internal-to-external gap more than either of the two current practices:
- discarding unstable features, or
- harmonizing each time point independently.
Relation to Prior Work
The method we extend is DAFIT, from Optimal Statistical Incorporation of Independent Feature Stability Information into Radiomics Studies. DAFIT estimates each feature's scanner and reader noise from side studies and injects that noise into the training data. The authors showed that hard filtering of unstable features costs over 5% AUC on sphericity-dependent targets, and that ignoring instability overestimates real-world AUC by nearly 20%. DAFIT works on static, single-time-point features from LIDC-IDRI. Applied naively to deltas, it would perturb the pre and post features independently, which is equivalent to setting $\rho = 0$ for every pair. That overstates noise for matched pairs and throws away signal, the same failure DAFIT itself identified for filtering.
Our contribution is to estimate $\rho$ and the per-time-point variances as functions of the acquisition-match type. That function is the ingredient our ablations isolate.
Three sets of prior work constrain or motivate the design:
- Single-center 3D change models. Fan et al. computed 3D Jacobian change maps from breast MRI registration and reported deltaRAD AUC 0.726 on 114 single-center patients. Liu built a 3D longitudinal network (MK-UNet) on volume change rate from 420 single-hospital scans and named multi-center validation as its main limitation. Both show that change signals carry information, but neither tests what happens when the two scans come from different acquisitions.
- Pooling across centers. Holzschuh et al. showed that pooling four centers in nnU-Net held a median Dice score of 0.74 under leave-one-center-out testing. We adopt that protocol, but pooling alone does not address within-patient mismatch.
- Reader studies. Yuan et al. and Wang et al. ran reader studies for static CT tasks; Wang's 3D ensemble reached 77.6% grading accuracy against 66.23% for senior radiologists. Wang's model also requires 0.5–1.5 mm slices. That requirement is the thick-slice brittleness we target, and no delta study we found benchmarks against readers at all.
Research Program
We will assemble a retrospective multi-center cohort of neoadjuvant-treated non-small cell lung cancer patients with pre- and post-treatment CT and pathologic response labels, modeled on the Zheng design. Each scan pair will be labeled by acquisition-match type: same scanner and protocol, same vendor with a different kernel, different vendor, or different slice thickness. Zheng's cohort itself would be ideal if shared. We cannot assume this; it remains a dependency.
Estimating the noise model. Noise parameters will be estimated without repeat patient scans. Instead, we will create controlled perturbations of the same acquisition:
- re-reconstruct or resample thin-slice scans to thick slices,
- apply kernel-like filtering,
- perturb segmentations to mimic reader variance, following the observer-variability logic DAFIT drew from LIDC-IDRI.
Applying the perturbation to one or both scans of a pair yields empirical estimates of $\sigma_t$ and $\rho$ for each match type and each feature.
Feature-space arm. Training augments each pair's pre, post and delta features with noise drawn from the covariance for that pair's match type. At deployment, the model uses the match type of the test pair, which is known from DICOM headers. Learners are logistic regression, LASSO and random forest, matching the Zheng and DAFIT pipelines.
Image-space arm. This arm targets volumetric context loss. A two-branch 3D network reads co-registered pre and post tumor crops. During training, the follow-up crop alone is degraded to thick-slice and alternate-kernel versions, so the network learns change representations that survive acquisition mismatch. Registration will use the fast 3D CT method of the deep-learning DIR study, which reports under 300 ms per pair. This arm tests whether the same principle carries over from hand-crafted to learned 3D features. It is secondary to the feature-space claim.
Baselines
Clinical baselines (the "do nothing" point). The naive reference is RECIST 1.1 response category and relative change in tumor volume. These are what clinicians use now, and they need no radiomics. They will be computed on the same segmentations.
Readers. The expert reference is a reader study. Junior and senior thoracic radiologists will view the full pre/post CT pairs and estimate the probability of complete response, in the tiered design of Yuan et al.. No reported result was found on Lacuna for radiologist accuracy at predicting pathologic complete response from serial CT, so this reference is new measurement, not a borrowed number.
Strongest existing method. This is the Zheng combined pre/post/delta logistic model, re-implemented on our cohort with the same feature extraction, segmentation and tuning budget as our method. The reported reference is external-test AUC 0.78 against internal 0.85 (Zheng et al.). Beating it means a higher pooled leave-one-center-out AUC that is also significant on mismatched pairs. We also require that the gap between internal and external AUC shrink by at least half.
Harmonization baselines. We will run three, all tuned with an equal search budget:
- independent per-time-point harmonization of features by scanner, in the spirit of Harmonizing Radiomic Features Across Medical Imaging Platforms;
- resampling all scans to a common thick-slice geometry before feature extraction;
- stability filtering.
Ablation of the key ingredient. This compares DAFIT-style independent noise ($\rho = 0$ for all pairs) against our pair-conditional noise. If the two perform the same, the core claim fails.
Why not just…?
Why not just harmonize features at each time point? Per-scanner harmonization removes average shifts in location and scale for each scanner. It does not tell the learner that a delta from a mismatched pair is less reliable than one from a matched pair, and it can remove real between-center differences in disease. Our harmonization baseline and the mismatched-subgroup analysis will show whether it already closes the gap. If it does, we will report that.
Why not just apply DAFIT to the pre and post features separately? This is the closest competitor. It is the explicit ablation above: it corresponds to setting $\rho = 0$ everywhere. The equation predicts it will over-penalize matched pairs. If it matches our method, that falsifies the claim that correlation structure matters.
Why not just pool data from many centers? Holzschuh et al. shows pooling helps segmentation. However, the dominant center supplied about 60% of that cohort, and pooling leaves rare mismatch types underrepresented. Pooled training without augmentation is the Zheng baseline under leave-one-center-out testing, so the comparison is built in.
Why not just resample everything to thick slices? This is a real threat. It might remove most of the mismatch at the cost of thin-slice shape detail. We include it as a full baseline. If it matches our method on mismatched pairs and loses little on matched pairs, the simpler fix wins and we will say so.
Proposed Experiments
The primary evaluation is leave-one-center-out AUC for complete response, with calibration slope. Results will be stratified by acquisition-match type and compared with DeLong tests.
The decisive check is the AUC on mismatched pairs. Our method should lose little on mismatched pairs relative to matched ones, while the Zheng baseline and the independent-noise ablation should show a clear drop.
A second check is reader-relative. Whether any model's advantage over senior radiologists persists on mismatched and thick-slice pairs matters more clinically than average AUC. Readers may handle mismatch better than models, and finding that would itself be informative.
A third check concerns shape features. We will test whether the sphericity and flatness deltas that Zheng found predictive keep their model weight under pair-conditional noise, or are down-weighted specifically on thick-slice follow-ups. Down-weighting on thick-slice follow-ups would confirm the proposed link between volumetric context loss and delta instability.
Finally, the image-space arm is judged on the same subgroups. The question is whether follow-up-only degradation during training helps learned 3D change features as much as pair-conditional noise helps hand-crafted ones.
References
- Temporal radiomics for non-invasive preoperative prediction of pathologic complete response to neoadjuvant chemoimmunotherapy in non-small cell lung cancer
- Optimal Statistical Incorporation of Independent Feature Stability Information into Radiomics Studies
- Radiomics of Tumor Heterogeneity in Longitudinal Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Predicting Response to Neoadjuvant Chemotherapy in Breast Cancer
- AI-based non-invasive profiling of the tumor immune microenvironment using longitudinal CT radiomics predicts immunotherapy response in lung cancer
- The impact of multicentric datasets for the automated tumor delineation in primary prostate cancer using convolutional neural networks on 18F-PSMA-1007 PET
- Deep learning CT model for stratified diagnosis of pancreatic cystic neoplasms: multicenter development, validation, and real-world clinical impact
- An ensemble deep learning model for risk stratification of invasive lung adenocarcinoma using thin-slice CT
- Deep-Learning-based Fast and Accurate 3D CT Deformable Image Registration in Lung Cancer