Many imaging diagnoses that look like two classes are really one continuous quantity cut at a threshold. A stroke patient can receive clot-dissolving drugs only if the stroke began less than 4.5 hours ago. When the onset was not witnessed, doctors estimate this from how the lesion looks on two MRI sequences. Diffusion-weighted imaging (DWI) lights up within minutes. FLAIR, a sequence that suppresses fluid signal, shows the lesion only gradually over hours. A lesion that is bright on DWI but not yet on FLAIR (a "mismatch") suggests an early stroke. Near the cutoff the two classes look nearly identical, because the underlying signal changes smoothly with time. Current models learn only a binary mismatch label, and they fail exactly there. Kim et al. report external AUCs of 0.883–0.913 on curated clear-cut cases but only 0.829–0.835 once subtle, heterogeneous cases are included. That drop is a small-scale preview of what happens when a model leaves curated retrospective data for an uncurated hospital stream.
We propose to supervise the model with the continuous quantity the label summarizes: time from symptom onset to scan. The model predicts a full probability distribution over that time, not a yes/no. Two lessons from binding-affinity prediction for drugs motivate this. Thresholding a continuous physical quantity discards the information needed to rank near-boundary cases (Giguère et al.; Moon et al.). And quantile outputs give usable uncertainty and applicability bounds (SimBoost, whose SimBoostQuant variant does this for affinities). The core claim is testable. Continuous, censoring-aware supervision should shrink the performance penalty on borderline cases, and that shrinkage should carry over to a prospective silent deployment. A binary classifier's score, even when calibrated, should not show the same gain.
Core Claim
When a clinical label is a threshold on a measurable continuous variable, borderline cases are not label noise. They are the most informative training examples, provided they are supervised with the continuous value. We predict three measurable consequences. First, the gap between curated and inclusive evaluation sets narrows. Second, discrimination improves specifically on the cases that are ambiguous to radiologists. Third, the model's uncertainty intervals keep their stated coverage when moved to live data.
Most of the skeptic's objections reduce to one ingredient, so we isolate it. The ingredient is the supervision signal, meaning the source of the training labels. The loss function is a secondary choice. We therefore compare the same network trained on binarized labels against the same network trained on continuous, censored onset times.
Why This Setting, and What Prior Work Leaves Open
The three input directions play different roles here. Affinity regression supplies the method and the argument against thresholding. Radiological feature overlap defines the regime where the argument matters. The retrospective-to-prospective gap is the evaluation target.
Overlap work in chest imaging supplies attention mechanisms, but these papers keep categorical objectives. DualAttNet fuses global and lesion-level attention for multi-label chest X-ray detection using binary cross-entropy. Meng et al. validate a binary COVID-versus-bacterial-pneumonia CT classifier with eight readers. Mishra et al. show that feature spaces collapse when classes share anatomy. None of them asks whether a continuous target would prevent that collapse. We do not propose a new attention module; we change what the network is asked to predict.
Prospective work shows why deployment is the right yardstick. Ng et al. ran a three-phase live mammography rollout. The Sontag paper documents alert fatigue from threshold-based alerts. Wang et al. describe spectrum bias, where curated sets drop the borderline cases that dominate live streams. All of these evaluate discrete flags. No one has measured whether continuous supervision changes the size of the prospective penalty.
The stroke setting has a structural feature that affinity datasets share. Their labels are heterogeneous and partly censored: some measurements are recorded only as "weaker than the assay limit." The research file notes this label heterogeneity. Stroke onset times are censored in a similar way. Witnessed strokes give a near-exact time. Wake-up strokes give only an interval, from last-seen-well to symptom discovery. Binary pipelines typically discard or force-label these cases. They are exactly the target population, and a censoring-aware likelihood lets them contribute to training.
Research Program
The model is a 3D convolutional network over co-registered DWI and FLAIR volumes. Its backbone is matched to the architecture class of Kim et al.. Its head outputs a discretized distribution over log onset-to-scan time $t$. For each patient $i$, the label is an interval $[a_i, b_i]$. For witnessed onsets the interval is narrow, set by the recording precision. For wake-up strokes it runs from last-seen-well to symptom discovery. The training objective is the interval-censored likelihood
$$ \mathcal{L} = -\sum_i \log \big( F_\theta(b_i \mid x_i) - F_\theta(a_i \mid x_i) \big), $$
where $x_i$ is the image pair and $F_\theta$ is the model's predicted cumulative distribution over onset time. Three outputs follow directly from $F_\theta$. The treatment-relevant probability is $F_\theta(4.5\,\text{h} \mid x)$, which allows AUC comparison with binary models. A point estimate and an 80% interval come from the distribution's quantiles. The interval can then be recalibrated with split conformal prediction on a held-out site.
The data plan follows the structure of the Kim et al. cohorts: a large derivation set and two external sites. It requires the onset-time fields and each case's assignment to Label Set I (inclusive) or Label Set II (curated clear-cut). We will pursue this through collaboration with the authors or an equivalent multicenter registry. Both label sets are retained, so the curated-versus-inclusive gap can be measured directly.
The work runs in three stages. First, a retrospective comparison on the external sites. Second, a reader study modeled on the washout design of Meng et al.. Radiologists read the same scans unaided, with a binary mismatch flag, or with a continuous estimate plus interval (for example, "3.8 h, 80% interval 2.9–5.1 h"). Third, a silent prospective deployment in an emergency stroke pathway. The model scores consecutive MRIs in real time without influencing care, and the logged predictions are later compared against onset times established during the admission. This is the smallest prospective step that directly measures the retrospective-prospective penalty. It avoids the regulatory load of an interventional trial.
Baselines
The naive reference point has two parts. The first is the prevalence rate. The second is the radiologists' own visual mismatch rating, which is the current clinical practice. Any model must beat that rating on the inclusive set to matter.
The strongest existing method is a binary 3D CNN in the style of Kim et al. trained on the inclusive labels. That paper reports AUCs of 0.862 (internal) and 0.829 and 0.835 (two external cohorts) on Label Set I. On Label Set II it reports 0.934, 0.883 and 0.913, with Brier scores between 0.02 and 0.23. We will reimplement this baseline on identical splits, with the same backbone, augmentation, compute and hyperparameter-search budget as our model. We will not rely on the published numbers alone.
Beating this baseline means two things together: an improvement in external Label Set I AUC, and a reduction in the Label Set II minus Label Set I gap, both with bootstrap confidence intervals excluding zero. The gap is currently about 0.05–0.08 AUC in the published external cohorts. We have no reported result on Lacuna for continuous onset-time regression on stroke MRI, so the continuous model has no prior number to beat.
The key ablation keeps our architecture and output head unchanged but replaces the censored onset times with the binary label. This isolates the supervision signal. A second ablation trains the continuous model only on witnessed onsets, which isolates the value of the censored wake-up cases.
Why not just…?
Why not just use the binary classifier's sigmoid probability as the continuous score? This is the default and must be beaten head-to-head. The binary classifier sees borderline cases only through a label that is often wrong or arbitrary for them. Kim et al. attribute their inclusive-set drop to boundary ambiguity rather than to feature extraction. In the affinity setting, Giguère et al. note that binary training saturates scores inside a class. Post-hoc calibration fixes probability scale but cannot recover ranking information that the labels never contained. The label-binarized ablation tests this directly. If the ablation matches our model on borderline cases, the claim is false.
Why not just train an ordinal classifier with several time cutoffs (under 3 h, under 4.5 h, under 6 h)? This is the real threat, because a multi-cutoff classifier is a coarse version of distributional regression. If it matches our model, the conclusion is still useful: continuous supervision is what matters, not the regression loss. We will run it with the same budget and the same censored labels, which map naturally onto cutoff indicators. We will then report whether the finer continuous output adds anything beyond interval width and calibration.
Why not just use soft labels from reader disagreement, or abstain on uncertain cases? Reader disagreement measures how hard a case is to see. Onset time measures where the case actually lies on the biology. Only the latter can tell an early stroke that looks late apart from a genuinely late one. Abstention reduces errors, but it returns the hardest cases to the same clinicians who disagree on them: Meng et al. report an unaided inter-reader kappa of 0.34 in a comparable overlap task. We include a soft-label baseline and a selective-prediction baseline, and compare them at matched coverage, meaning the same fraction of cases on which each model gives an answer.
Why not just do a larger multicenter retrospective validation instead of a prospective one? Jiang et al. reached AUROC 0.906 retrospectively for detecting microvascular invasion in liver cancer and still concluded that prospective trials are needed before clinical use. Our central hypothesis is about the size of the retrospective-prospective penalty. It can only be measured on consecutive, uncurated scans, so the silent deployment is the measurement itself, not an extra.
Proposed Experiments and Decisive Checks
The first check is retrospective. On both external sites, we compare Label Set I AUC and the Label Set I–II gap for our model, the binary baseline, the ordinal classifier and the ablations. We report separately on the borderline cases, those in Label Set I but not Label Set II, because that is where the hypothesis predicts gains.
The second check is calibration under shift. Conformal intervals fitted on one site should hold roughly 80% coverage on the other. The Brier score at 4.5 h should improve on the published range.
The third check is the reader study. Primary outcomes are treatment-eligibility agreement between readers (kappa), accuracy against known onset time, and reading time. The comparison is continuous-with-interval display against binary flag, benchmarked against the kappa improvement from 0.34 to 0.58 reported by Meng et al. for binary assistance.
The decisive check is prospective. We compute the penalty for each model: the drop in AUC and in interval coverage from the retrospective external sites to the silent deployment stream. The proposal succeeds if the continuously supervised model's penalty is smaller, with a confidence interval excluding zero, than both the binary and ordinal baselines. It fails if the penalties match. That outcome would mean spectrum shift in live stroke imaging is not driven by the thresholded label.
References
- Deep learning-based classification of diffusion-weighted imaging-fluid-attenuated inversion recovery mismatch
- Learning a peptide-protein binding affinity predictor with kernel ridge regression
- PIGNet2: a versatile deep learning-based protein–ligand interaction prediction model for binding affinity scoring and virtual screening
- SimBoost: a read-across approach for predicting drug-target binding affinities using gradient boosting machines
- DualAttNet: Synergistic fusion of image-level and fine-grained disease attention for multi-label lesion detection in chest X-rays
- AI support for accurate and fast radiological diagnosis of COVID-19: an international multicenter, multivendor CT study
- Self-supervised Learning of Echocardiographic Video Representations via Online Cluster Distillation
- Prospective implementation of AI-assisted screen reading to improve early detection of breast cancer
- Creating an automated trigger for sepsis clinical decision support at emergency department triage using machine learning
- Automated segmentation and diagnosis of pneumothorax on chest X-rays with fully convolutional multi-scale ScSE-DenseNet: a retrospective study
- Preoperative identification of microvascular invasion in hepatocellular carcinoma by XGBoost and deep learning