Tracking the Neutrophil-to-Lymphocyte Ratio Between Blood Draws

The neutrophil-to-lymphocyte ratio (NLR) is a cheap inflammation score computed from a routine blood count. It is almost always used as a single number taken at hospital admission. That habit throws away information, and it may explain the score's best-known failure. Among 5,056 ICU patients, admission NLR tracked mortality across the whole cohort but showed no relationship with mortality among septic patients (Salciccioli et al.). We propose treating the inflammatory state as a hidden quantity that changes hour by hour. The bedside monitor watches it continuously through vital signs. The laboratory measures it exactly, but only when blood is drawn. A filter combines the two and gives a calibrated hourly estimate of NLR and its relatives, along with a rule for deciding when the next blood draw is actually worth taking.

The method comes from remote state estimation with asymmetric information, the problem of two parties who each see different parts of a changing system. One party here is the lab, which sees exact counts at sparse times. The other is the monitor, which sees noisy, correlated signals all the time. The clinical question comes from composite inflammatory indexing. Two observations make the borrowing work. The first is that every standard composite index is a straight linear combination once you take logarithms of the cell counts, so the Gaussian tracking machinery applies directly. The second is that the scarce resource is not bits on a network. It is blood draws, each of which costs patient blood volume and lab time. Our main claim is that a log-space filter using vital signs as side information can rebuild the NLR trajectory between draws with calibrated uncertainty. We also claim that features of this trajectory recover prognostic signal in sepsis that the admission snapshot lacks.

Core Claim

Let $x_t = (\log N_t, \log L_t, \log P_t, \log M_t)$ be the log neutrophil, lymphocyte, platelet and monocyte counts at hour $t$. Then $\log \text{NLR} = \log N - \log L$, $\log \text{SII} = \log N + \log P - \log L$, and $\log \text{SIRI} = \log N + \log M - \log L$. Each is $c^\top x_t$ for a fixed vector $c$. We model $x_t$ as a linear Gauss-Markov state, meaning each hour's state is a linear function of the last hour's plus Gaussian noise. Two kinds of observation feed it. Laboratory draws give near-exact, sometimes partial readings of $x_t$; a total white count without a differential is a common example. Hourly vitals and other labs from the MIMIC-Extract aggregates give noisy linear readings at every hour.

A Kalman-type filter gives a posterior mean $\mu_t$ and covariance $\Sigma_t$ for the state. From these, the index estimate on the original scale is

$$\hat{I}_t = \exp\!\left(c^\top \mu_t + \tfrac{1}{2} c^\top \Sigma_t c\right),$$

the log-normal mean. The variance term in this formula is the correction that the naive estimate $\hat N / \hat L$ omits. That omission is the Jensen-inequality gap: the expected ratio is not the ratio of expected counts. The draw-scheduling rule is the event-triggered threshold policy

$$\text{draw at hour } t \iff c^\top \Sigma_t c > \tau,$$

where $\tau$ sets the uncertainty we tolerate in the index the clinician cares about. This adapts the threshold-transmission structure that Soleymani, Assaad and Baras prove optimal for remote estimation over lossy links with unreliable acknowledgments. The key change is that our trigger uses the uncertainty of the decision-relevant direction $c$, not the full state error. A draw that only sharpens platelets is wasted when the clinician is watching NLR.

Research Program

The work has three parts.

Identifying the dynamics. We fit the drift, process noise, and vital-sign observation model on MIMIC-III (Johnson et al.) using the hourly MIMIC-Extract representation (Wang et al.). The fit uses expectation-maximization over stays with at least daily complete blood counts. To stay tractable, the latent state is kept at four dimensions. This sits near the size where Soleymani et al. report grid-based policy computation becoming expensive. Because our trigger is a closed-form variance test rather than an optimized threshold over the full state, it does not need their grid search.

Separating real-time from retrospective estimates. Lev and Khina show that side information available only causally at the decoder is strictly less useful than side information available in advance. In their scalar Gauss-Markov setting, the causal rate-distortion function sits strictly above the Wyner-Ziv bound at every positive rate. We take this as a constraint on how we report results. Every number comes in two versions: a filter that uses only past vitals, and a smoother that uses the whole stay. Only the filter numbers are claimed as deployable, and the gap between the two measures the clinical version of their "causality tax."

Answering the sepsis question. Salciccioli et al. offer a saturation, or ceiling, explanation for the null result in sepsis but do not test it. We test whether trajectory features rescue NLR's prognostic value in sepsis: the filtered 48-hour slope of $\log$ NLR, time spent above a threshold, and posterior uncertainty.

The log-space choice has a side benefit for cross-site robustness. A multiplicative calibration offset between hematology analyzers becomes an additive bias in log space, which a per-patient baseline term absorbs. Ding et al. attribute their external-validation AUC drop, from 0.891 in training to 0.812 externally, partly to analyzer variation, so this property is worth testing directly.

We are deliberately not doing several things. We do not claim that network bandwidth is a bottleneck; sending a few lab values costs almost nothing. We do not use the rate-distortion-perception results of Hamdi, Wagner and Gündüz. Their realism constraint addresses outputs that look artificially smooth, which matters for generation, but a clinician needs a calibrated estimate, not a realistic-looking sample. We do not pursue the subset-universal codes of Ordentlich and Shayevitz. They are non-constructive, and a partial blood panel is handled directly as a partial observation in the filter.

Baselines

Naive reference. The do-nothing baseline is last observation carried forward: NLR from the most recent complete draw, held constant until the next one. In practice, this is what clinicians read, and it shows how much is lost between draws.

Strongest existing competitor. This is GRU-D, a recurrent network that handles irregular sampling with missingness indicators and learned decay toward the mean. MIMIC-Extract benchmarks it alongside LSTM, CNN, logistic regression and random forests, reporting mortality AUROCs between 0.85 and 0.90. It is the right competitor because it uses the same hourly data and learns cross-variable dynamics without our linear-Gaussian assumption. To keep the comparison fair, we train it on identical stays and splits. Its targets are log counts, so it is not handicapped by predicting raw ratios. We add a variance output head so it can drive the same scheduling rule, and we give it the same hyperparameter search budget, measured in GPU-hours, that we spend on the filter's EM restarts. Beating it means one of two things. Either we achieve lower error on held-out log-NLR at masked draw times, or we match its error with better calibration, measured as 90% interval coverage within two points of nominal. Neither model gets an advantage on the prognostic task beyond the features it produces.

Clinical score reference. SAPS I alone, and SAPS I plus admission NLR, replicate the Salciccioli analysis. They report an AUC increase from 0.746 to 0.757 when NLR is added. The 28-day mortality odds ratio for the top versus bottom NLR quartile was 1.71 (95% CI 1.35–2.16), with no significant relationship in sepsis.

Ablations. Three ablations isolate the ingredients. The first removes the vital signs, leaving lab draws only, to measure what the bedside side information contributes. The second replaces the log-space state with a raw-count state using the naive $\hat N/\hat L$ estimate, to measure the Jensen correction. The third replaces the index-directed trigger $c^\top\Sigma_t c$ with a full-state trace trigger, to test whether aiming the trigger at the index matters.

Scheduling reference. For draw scheduling, the baselines are periodic thinning at the same draw budget and random thinning. The only published threshold-scheduling figure in the file is outside medicine: on a spacecraft-tracking benchmark, Soleymani et al. cut transmissions from 443 to 377 at an MSE of 0.0479 versus 0.0486. We found no reported result on Lacuna for retrospective lab-draw thinning or held-out NLR reconstruction on MIMIC, so those baselines must be run by us.

Why not just…?

Why not just use GRU-D or a transformer and skip the structured filter? This is the real threat, and we treat it that way. The file gives no evidence that a learned sequence model reconstructs lab values poorly. The MIMIC-Extract results concern outcome prediction, not reconstruction. If GRU-D with a variance head matches the filter on both error and calibration, then the contribution narrows to the log-space formulation and the index-directed scheduling rule. The scheduling experiment tests that rule with both estimators, so it is evaluated independently of which estimator wins. Where we expect the filter to win is calibration on short stays and sparse-draw patients, where learned decay terms have little data.

Why not just add simple trend features, such as the change in NLR between the last two draws? This is cheap and may capture much of the sepsis signal. We include it as an arm of the sepsis analysis. The filter must beat delta-NLR on adjusted mortality discrimination, not merely beat the admission snapshot. If it does not, the useful finding is simply that trajectories matter, and the machinery is unnecessary for prognosis even if it still helps scheduling.

Why not just interpolate each count separately with a Gaussian process and take the ratio? Per-count interpolation ignores the vital-sign side information and the correlation between lineages. It also invites the Jensen bias when the ratio of means is taken. The raw-count, no-vitals ablation is essentially this baseline. If it matches the full model, our two main ingredients are not pulling their weight.

Why not just send every value, since bits are cheap? We agree that bits are cheap. That is why the scheduling rule decides blood draws, not network transmissions.

Proposed Experiments

Reconstruction. We use MIMIC-III adult stays of at least 48 hours with daily or more frequent complete blood counts. We hide 50% of draws, chosen at random, and score the held-out log-NLR, log-SII and log-SIRI. Metrics are mean absolute error, interval coverage, and continuous ranked probability score, a single score that rewards both accurate and well-calibrated probabilistic predictions. Each is reported for the filter and the smoother.

Scheduling. Each policy may keep only $k$ of a stay's existing draws, for budgets of 30–70%. We measure reconstruction error at the discarded draws and 28-day mortality AUROC computed from the thinned data. A known limitation is that this only lets a policy skip draws, never add them. It also inherits informative ordering: clinicians draw blood when worried, so the implicit information Soleymani et al. exploit, where silence implies low error, runs partly in reverse here. We report results stratified by whether a draw followed a vital-sign deterioration.

Sepsis test. This is the decisive check. In a sepsis cohort defined before any analysis, we fit logistic models for 28-day mortality adjusted for SAPS I. We compare admission NLR, delta-NLR, and filtered trajectory features. The hypothesis is supported if trajectory features carry a significant adjusted association and improve AUC where admission NLR is null. It is refuted if they also fail in sepsis, which would point to biological decoupling rather than a measurement artifact.

Robustness. We train on one MIMIC-III recording-system era and test on the other (CareVue versus MetaVision). This checks whether the per-patient log baseline limits the cross-site degradation Ding et al. observed.