Touch-Queried Polyp Segmentation with an Amplified Torque Probe

Colonoscopy segmentation networks fail most often on flat polyps. These lesions have almost the same color and texture as the healthy colon wall around them, so there is little visual evidence to find. The gap is large. PraNet reaches a mean Dice of 0.898 on Kvasir-SEG but only 0.628 on the unseen ETIS-LaribPolypDB set (PraNet). Even Polyp-PVT's authors report failures under overlapping light and shadow and on specular glare (Polyp-PVT). In a separate literature, sensor designers build small mechanical structures such as spokes, flexure bridges and micro-levers that magnify a tiny force before it is measured. One such design, a spoke structure behind a needle tip read by fiber Bragg gratings (optical fibers whose reflected wavelength shifts with strain), resolves torques of 0.8 mN·m (Xiong et al.). This proposal connects the two literatures narrowly. It does not fuse a force stream into every video frame. Instead, the segmentation network decides where it is most uncertain, and the endoscopist briefly touches that spot with a probe that has a torque amplifier at its tip. Each touch yields one noisy "lesion / not lesion" label, and the network re-segments using those labels.

In two sentences: vision models fail exactly where the eye also fails, and a few mechanical measurements taken where the model is least sure could correct them. Torque amplification is what might make those measurements readable against the soft, low-contrast mechanics of mucosa. It may not be enough. The proposal is designed so that we find this out first and cheaply.

Core Claim

The claim is conditional, and it has two parts. First, a small rotational sweep of a probe tip against the mucosa produces a measurable difference in torque resistance between a flat polyp and the surrounding tissue, provided the torque is mechanically amplified. Second, if that difference exists, three to five uncertainty-directed probe labels will raise Dice on flat and camouflaged polyps more than two alternatives would. The first alternative is the same number of clicks placed by an observer looking at the image. The second is the same number of probes using unamplified axial force.

The piece that is new is the probe placement. The segmentation model chooses the location from its own uncertainty, and a mechanical signal answers the query. No prior work in the file does this.

The closest work is bimodal tactile tomography (Bimodal Tactile Tomography). It uses Bayesian sequential palpation with an optical-coherence tactile sensor to localize stiff inclusions in 30 iterations or fewer. It works only on silicone and fruit phantoms, with no camera image and no segmentation network, so the search starts from nothing. We start from a vision prior and want a handful of touches, not tens.

Xiong et al. supplies the sensing method: a spoke amplifier, a torque grating, an axial grating, and a reference grating for temperature compensation. That device was only bench-calibrated with pure loads up to 10 mN·m and never touched tissue. The vision-as-force line, such as V-ANFIS (Avilés et al.), infers force from video deformation. It therefore inherits the same occlusion and glare problems that break segmentation, which is why it cannot provide an independent check.

Research Program

Stage one: is there a physical signal at all? This is a feasibility gate. Nothing in the file shows that polyp and normal mucosa differ in torsional resistance. The only relevant precedents are stiffness differences between hard inclusions and phantoms, which are much larger than anything expected in real tissue.

We would adapt the spoke-type structure to a through-the-scope probe with a rounded, low-friction tip. The low-friction surface treatment is borrowed from the superhydrophobic work of Chen et al.. That work reduces friction in rotating parts, so here it would limit drag and abrasion at the tissue. It is one option, not a commitment. We would then measure peak torque during a fixed small twist at controlled axial preload.

The test tissue is ex vivo porcine colon containing lesion mimics of graded stiffness and thickness. These include submucosal injections and embedded soft inclusions, plus resected human polyp specimens if an ethics-approved source is available.

The quantity that decides everything is a detectability ratio:

$$d = \frac{|\bar T_{\text{lesion}} - \bar T_{\text{normal}}|}{\sigma_T},$$

Here $\bar T$ is the mean peak torque on each tissue type at matched preload, and $\sigma_T$ is the standard deviation of repeated measurements on the same tissue. That spread includes sensor noise, tissue variation and preload error. Since a label's error rate falls with $d$ roughly as a Gaussian tail, this single number sets how noisy the touch labels will be downstream.

We would run the same protocol with the spoke amplifier replaced by a plain beam. This isolates what the amplification contributes.

Stage two: does a noisy touch label help segmentation? This stage can run in parallel on public data. Real paired video and force data do not exist (the file lists no such dataset), so we simulate. The segmentation model is a strong vision model extended to accept sparse positive and negative point labels, using a Polyp-PVT-style encoder with a point-prompt input. It proposes up to $k$ probe locations, taken at the points of highest predictive entropy after the first pass.

The simulator returns the ground-truth label at each location, flipped with a probability derived from the stage-one $d$. It also adds a positional error that matches the endoscopist's expected targeting error. We then re-segment and report Dice.

Sweeping $d$ traces a curve of segmentation gain against signal quality. Stage one then says where on that curve real hardware sits. This split keeps the machine learning question answerable even if the hardware work stalls.

Stage three: paired ex vivo trials. If stage one gives a useful $d$, we would record colonoscope video of the ex vivo specimens alongside the grating readings, with the probe tip tracked in the image. This produces a small paired set that can check the simulation. It is a pilot dataset, not a benchmark.

Baselines

The naive reference point is the vision model alone, with no queries. It is trained on Kvasir-SEG and CVC-ClinicDB and tested unseen on ETIS and CVC-ColonDB. The strongest vision-only numbers in the file are from Polyp-PVT: mean Dice 0.787 on ETIS and 0.808 on CVC-ColonDB (Polyp-PVT). CaraNet reports 74.7% on ETIS (CaraNet). We would retrain Polyp-PVT ourselves on the same splits and with the same augmentation, so that our query model differs only in its point-label input. Any gain we report is measured against our own reproduction, not against the published figure.

The strongest competitor on this specific question is interactive segmentation driven by visual clicks. This is the same point-prompt model, but the $k$ clicks come from a simulated observer who can only click where the image shows visible evidence. We define that as regions where a vision-only saliency or edge model has confidence above a threshold. The same model and the same $k$ are also run with oracle clicks placed at random inside the ground-truth mask, which gives an upper bound. Foundation-model routes such as Polyp-SAM and SAM-Mamba belong in this group as prompted models. For SAM-Mamba no reported result was found on Lacuna for ETIS with a matching protocol, so we would run it ourselves under the same prompt budget.

To beat this baseline, the model's torque-queried labels must improve Dice on the flat and camouflaged subset of ETIS by more than visual clicks do at equal $k$. The gain must hold across seeds, with non-overlapping bootstrap intervals. Improvement on easy, visible polyps does not count, because clicks already handle those.

Two ablations isolate the key ingredients. The first swaps uncertainty-chosen probe locations for random locations within the frame, which tests whether the active query matters. The second swaps the amplified torque channel for the unamplified axial-force channel of the same probe, which tests whether amplification matters. Each ablation uses the $d$ measured for that channel in stage one.

Why not just…?

Why not just keep improving the vision model? This is the default, and it may win on average. Large domain-shift drops such as PraNet's fall to 0.628 on ETIS (PraNet) have narrowed with transformers and distillation from foundation models (From SAM to DINOv2). Our claim is therefore limited to the subset of polyps whose images genuinely lack contrast, and the headline metric is computed on that subset. If the strongest vision baseline already segments that subset well, the proposal has nothing to offer, and the stage-two results will show it.

Why not just let the endoscopist click on the lesion? This is the real threat. A click costs nothing and needs no hardware. The answer depends on where labels can be obtained. An observer cannot click on a boundary they cannot see, while a probe can report tissue mechanics there. The visual-click baseline is built to capture exactly this limit. If clicks confined to visible regions match torque queries on the camouflaged subset, the mechanical channel adds nothing, and we would report a negative result.

Why not just use axial force, or a simple unamplified sensor? Pressing straight down is simpler and less likely to abrade tissue. The file gives no evidence that it discriminates flat mucosal lesions. The measured $d$ for each channel settles this directly. If axial force yields a comparable $d$, the torque amplifier is unnecessary and the design should drop it. Only a clearly higher $d$ for amplified torque would justify the extra mechanical complexity.

Why not infer force from video instead? Vision-as-force methods (Avilés et al.) need a known tissue compliance. They degrade under occlusion and glare, which are the same conditions under which segmentation fails, so their errors are correlated with the model they are meant to check. We would include video-estimated deformation as a further query channel in stage three, to test whether it adds any independent information.

Decisive Checks

The first check is the stage-one detectability ratio on ex vivo lesion mimics. If amplified torque does not exceed unamplified axial force by a clear margin, and if neither channel reaches the $d$ at which the stage-two curve shows a gain on camouflaged polyps, the hardware direction stops. The simulation curve is still published as a specification for any future tactile channel.

The second check is the stage-two comparison on the flat and camouflaged subset of ETIS and CVC-ColonDB, at $k$ from one to five. Torque-queried Dice is compared against visual clicks and the vision-only baseline, alongside the random-location ablation. Latency is reported against PraNet's roughly 50 fps reference speed. The query step adds only one extra forward pass per touch, so it should stay within the real-time limit of about 40 ms per frame identified by Bernal et al..

The third check is agreement between the simulated gain and the gain measured on the small stage-three paired set. Tissue abrasion is scored histologically after repeated touches, to address the risk flagged in the tactile tomography work.