A model pretrained on 700,000 person-days of UK Biobank wrist accelerometry recognizes human activity much better than models trained from scratch. It is also a deep convolutional network built for servers. A wrist device has no fan and sits against skin that should not be warmed past roughly 41–43°C. It cannot run such a network on every window of sensor data without eventually throttling its clock or warming the wearer. This proposal does not shrink the big model further. It asks when the big model is worth running. The UK Biobank recordings show how people move: long stretches of sitting and sleep, broken by bursts of walking, exercise and chores. Those bursts are exactly when a cheap classifier is most likely to be wrong. They are also when the skin under the device is already warm. The recordings can therefore serve two purposes. They are a population-scale record of the device's future compute demand, and they can train a forecaster that predicts that demand.
The concrete idea is a heat governor built on a two-tier design. A tiny always-on classifier covers the easy stretches. The biobank-pretrained network is invoked selectively. A small activity forecaster, learned from UK Biobank, predicts the next few minutes of movement. The governor then banks thermal headroom ahead of predicted bursts, for example by deferring background work. It spends that headroom on big-model inference when the forecast and the cheap model's uncertainty both say it matters. The system is evaluated by replaying real UK Biobank person-days through a calibrated thermal model of real wearable hardware. It is not evaluated on synthetic task sets.
Core Claim
Heat-aware scheduling on wearables fails for a specific reason. The schedulers assume the heat each task will produce is known in advance, and in wearables that heat depends on what the person does next. Algorithms for temperature-aware task scheduling in microprocessor systems proves that offline temperature-aware scheduling is NP-hard and that reasonable online algorithms are 2-competitive under a simple cooling model. Its authors name unknown-but-predictable heat contributions as the open direction. We claim that human movement is predictable enough at minute scale, from recent activity history and time of day, for a forecast-driven governor to beat both reactive throttling and uncertainty-only gating. The measure is big-model coverage of hard windows under a fixed skin-temperature ceiling. UK Biobank is what makes the claim testable at population scale. We will check this claim directly and could falsify it.
Research Program
The first component is the pair of classifiers. The large tier is the ResNet-V2 from Self-supervised learning for human activity recognition using 700,000 person-days of wearable data. That work pretrains on unlabelled UK Biobank accelerometry with three self-supervised tasks: detecting whether a clip plays backwards, detecting shuffled segments, and detecting time warping. It then fine-tunes on eight labelled activity datasets. We reuse its weights and fine-tune on Capture-24, a labelled free-living wrist dataset. The small tier follows HDUQ-HAR. It uses hyperdimensional computing, which classifies by comparing long binary codes with bitwise operations. On top of that sits conformal prediction, which outputs a set of plausible labels with a coverage guarantee. HDUQ-HAR runs in 3–5 ms per window in about 6–9 KB of RAM on a Cortex-M4. We adopt it because its prediction-set size is a calibrated signal of when the cheap model is unsure. We add one change: the small tier is distilled from the large tier's predictions on unlabelled UK Biobank windows, so the two tiers disagree mainly where the problem is hard. Where they disagree for other reasons, the distillation has failed. DistHD regenerates weak code dimensions during training, and we use it to choose the small tier's size.
The second component is the forecaster. It is trained on UK Biobank person-days to predict the distribution of movement intensity over the next one to ten minutes, given the past hour of the cheap model's outputs and the clock time. The model is deliberately tiny, a small recurrent or gradient-boosted model, so that it costs less heat than it saves. UK Biobank supplies the scale needed to learn the population prior and to measure honestly how predictable activity onset is. It also supplies the imbalance that makes the whole approach possible. The SSL paper had to reweight sampling because most recorded time is sedentary or asleep. For our purposes, that dominance of quiet time is the opportunity rather than a nuisance.
The third component is the thermal model and the governor. Following the software thermal sensor work, we estimate temperature in software. That work turned activity counts into power and then into temperature through a resistor–capacitor heat network, stayed within 0.08°C of HotSpot at under 3% overhead, and exposed 12–15°C swings within a second that on-die sensors miss. We collapse that approach to the package-and-skin scale:
$$T_{t+1} = T_t + \frac{\Delta t}{C}\left(P_t - \frac{T_t - T_{\text{amb}}}{R}\right)$$
Here $T_t$ is the device back-plate temperature at step $t$, $P_t$ the power drawn by whatever runs in that step, $T_{\text{amb}}$ the local ambient temperature (skin plus environment), $\Delta t$ the step length, and $R$ and $C$ the thermal resistance and capacitance, fitted per device. Chrobak's halving model is the special case with fixed step and unit constants. At each window the governor makes three choices: whether to run the large tier, whether to defer background work, and what clock setting to use. It chooses to maximize expected accuracy gain, meaning the forecast probability that the window is hard times the expected large-tier improvement. The constraint is that the predicted $T$ over the forecast horizon stays below the ceiling. $T_{\text{amb}}$ rises during exercise, so the forecaster also tells the governor when the budget is about to shrink.
2D-ThermAl maps chip power maps to steady-state temperature maps in under 10 ms with 0.71°C error. It is the wrong tool here, because the binding limit on a wearable is transient skin contact temperature rather than on-die spatial gradients. We cite it to explain why we do not use it.
Baselines
The naive reference point runs the large tier on every window at full clock. It gives the accuracy ceiling. It also shows whether thermal limits bind at all on the chosen hardware. If they do not, the project reduces to an energy study, and we will say so.
The second reference is always-on HDUQ-HAR alone. It never produces meaningful heat and is the floor for accuracy. No reported result was found on Lacuna for HDUQ-HAR on Capture-24, so we measure it ourselves.
The strongest existing accuracy reference is the fine-tuned UK Biobank ResNet-V2. Its paper reports a median relative F1 improvement of 24.4% (range 2.5–130.9%) over supervised baselines across eight datasets, and a 55.4% gain on Opportunity. No reported result was found on Lacuna for its absolute Capture-24 F1, so we reproduce it.
The strongest competing system is a reactive governor. It runs the large tier whenever the conformal set size exceeds one, and it applies hardware-style clock throttling at the temperature trip point. This is what a careful engineer would build from existing parts without any forecasting.
A DeepWear-style variant offloads the large tier to a paired phone. DeepWear splits networks between watch and phone for 1.95–2.62× speedup and up to 53.5% wearable energy savings, but it ignores temperature. We include it as a system that moves heat off the wrist entirely.
The decisive ablation keeps our full system and replaces the learned forecaster with a persistence forecast ("the next minutes look like the last minute"). A second ablation removes the forecast entirely, which recovers the reactive governor.
All methods share the same fine-tuned weights, device, thermal calibration, replayed person-days and skin-temperature ceiling. Each receives the same hyperparameter search budget over its thresholds on a validation split of participants. Beating the reactive governor means higher macro-F1 on hard windows at equal time-above-ceiling, with confidence intervals from participant-level bootstrap. We will count a gain of under one F1 point as a null result.
Why not just…?
Why not just duty-cycle the big model at a fixed low rate? Fixed duty cycling spends inference uniformly. The UK Biobank imbalance means most of that inference lands on sleep and sitting, where the cheap model already agrees with the big one. We include fixed duty cycling at matched average compute as a baseline, and the replay directly measures how many hard windows it misses.
Why not just rely on the hardware's reactive throttling? On-die sensors miss fast local swings, as the software-sensor work showed. Reactive throttling also triggers during exercise, which is exactly when accuracy matters. The model-checking scheduler found feasible temperature- and energy-constrained schedules where simple heuristics failed, but only for fixed task sets. The reactive-governor baseline above is how we test this alternative. If it matches our system, forecasting adds nothing and we report that.
Why not just run the tiny classifier all the time and forget heat? This is the most serious threat. If a distilled hyperdimensional classifier comes within a point of the UK Biobank ResNet on free-living data, there is nothing for a heat governor to arbitrate. The SSL paper compared against random forests and from-scratch networks, not against distilled microcontroller models, so the file contains no evidence settling this question. Our first experiment measures that gap per activity class before anything else is built. If the gap is small, the paper becomes that measurement.
Why not just offload everything to the phone? Offloading removes wrist heat. But DeepWear itself shows that radio cost can erase compute savings, and it requires a nearby phone continuously. We report the offloading variant's accuracy, wrist energy and availability under simulated phone absence. A system that falls back gracefully when the phone is away is a separate contribution only if the forecaster also improves that fallback.
Proposed Experiments
The first experiment is the gate for everything else. We fine-tune both tiers on Capture-24 and report macro-F1 overall and on high-intensity and transition windows. We then run the large tier continuously on a smartwatch-class processor and on a Cortex-M-class microcontroller with a neural accelerator. We log back-plate temperature against a heated skin phantom at 33°C and 40°C ambient. The project continues only if two conditions both hold: the accuracy gap on hard windows is material, and continuous large-tier inference approaches the ceiling on at least one realistic platform.
The second experiment tests forecastability. On held-out UK Biobank participants, we measure how well the forecaster predicts moderate-to-vigorous movement onset one to ten minutes ahead, compared with persistence. We break results down by age group and time of day. The cohort skews older and is a mostly healthy-volunteer, largely European sample, so we also test the forecaster on Capture-24 participants to check portability.
The third experiment is the main comparison. We replay several thousand UK Biobank person-days through each governor using the fitted thermal model. Since these days are unlabelled, accuracy is measured as agreement with the always-on large tier. We then validate on Capture-24 against true labels, and physically verify on hardware for a subset of replayed days. Every method is reported on the same four quantities: hard-window F1, minutes above the skin ceiling, wrist energy, and number of throttling events.
The decisive checks are two. The learned forecaster must beat persistence in the ablation. The full system must beat the reactive uncertainty-gated governor at equal heat. If neither holds, the honest conclusion is that calibrated uncertainty alone suffices for thermal budgeting on wearables.
References
- Algorithms for temperature-aware task scheduling in microprocessor systems
- Self-supervised learning for human activity recognition using 700,000 person-days of wearable data
- Efficient Uncertainty Aware Human Activity Recognition On Microcontrollers Using Hyperdimensional Computing And Conformal Prediction
- DistHD: A Learner-Aware Dynamic Encoding Method for Hyperdimensional Classification
- Efficient power modeling and software thermal sensing for runtime temperature monitoring
- 2D-ThermAl: Physics-Informed Framework for Thermal Analysis of Circuits using Generative AI
- DeepWear: Adaptive Local Offloading for On-Wearable Deep Learning
- Temperature- and energy-constrained scheduling in multitasking systems: a model checking approach