Most clinical sleep recordings are scored by one expert. A technician reads several simultaneous signals, including brain waves (EEG), eye movements (EOG) and muscle tone (EMG), and labels each 30-second window as Wake, N1, N2, N3 or REM. A model trained on those labels learns two things at once: the physiology, and that one person's habits. Those habits include when they tend to declare a stage change and which signal they trust when the signals disagree. Experts do disagree. On the five-scorer DOD-O benchmark, individual scorers reach only 0.69 to 0.74 macro F1 against consensus (U-Sleep: resilient high-frequency sleep staging).
We propose to model each scorer's bias as a small set of interpretable temporal operations applied to a shared, scorer-free "consensus" hypnogram, which is the stage-by-time sequence the model infers from the multichannel signals. A scorer's label is explained by three things: the consensus stage, a learned scorer-specific displacement of where boundaries fall, and a scorer-specific confusion between adjacent stages. Because these per-scorer parameters are few, they can be estimated for a new scorer from that scorer's labels alone. That is exactly the single-annotator setting where most training data lives. The central claim is testable: if most single-scorer bias in multichannel staging is temporal and concentrated at transitions, then factoring it out yields better agreement with an unseen expert panel than training directly on one scorer's labels, and better than bias models that ignore time.
Core Claim and How It Differs from Prior Work
Two strands of prior work motivate the idea. The first shows that annotator disagreement has structure. Demonstrating and Modelling Systematic Time-varying Annotator Disagreement in Continuous Emotion Annotation found that disagreement time series from independent rater groups on RECOLA are correlated (r = 0.19 for arousal, 0.11 for valence, p < 0.0001), and that ratings stay correlated for about five seconds. That work builds target distributions, using a mean-variance model and a Gaussian process over time. It does not train a network that consumes multichannel signals, and it does not separate individual raters. The second strand is Transformer-based Annotation Bias-aware Medical Image Segmentation (TAB). TAB learns one query per annotator "style" alongside a consensus query on fundus images. It also models execution noise with a low-rank Gaussian over pixels, and it reports higher consensus accuracy than consensus-trained baselines. TAB supplies the core move we reuse, which is to model individual raters in order to improve the shared estimate. It works on static 2D images, so its notion of style is a spatial margin. Ours is a temporal displacement and a choice of channel reliance.
The closest multichannel work treats labels as fixed truth. BSTT: A Bayesian Spatial-Temporal Transformer for Sleep Staging infers changing inter-channel graphs and finds stronger connectivity in N1/N2 than in N3. SleepSMC: Ubiquitous Sleep Staging via Supervised Multimodal Coordination weighs channels by their uncertainty under masking. Both capture uncertainty in the signal, never in the label. U-Sleep uses its five DOD scorers only as an after-the-fact yardstick. Stage Prototypes for Transition-Aware Temporal Modeling in Single-Channel Sleep Staging (SleepTSP) learns boundary scores without supervision on single-channel EEG. Its own limitations note that transition gains are diluted because steady segments dominate the loss. This constrains our evaluation: improvements must be measured in transition zones, not only in aggregate F1.
The novelty is therefore narrow and deliberate. We do not propose a new staging backbone. We propose a scorer-bias layer with explicit temporal structure, a protocol for fitting it from single-scorer labels, and a test of whether removing it recovers panel consensus.
The Model
A multichannel backbone maps a night of signals $x$ to a consensus posterior $z_t$ over the five stages at each epoch $t$. Scorer $r$'s label at epoch $t$ is modeled as
$$ p(y^r_t \mid x) = \sum_{\tau=-K}^{K} w^r_\tau(x)\, \big[C^r(x)\, z_{t-\tau}\big], $$
Here $w^r_\tau$ is a distribution over small temporal offsets $\tau$ of up to $K$ epochs, which captures whether scorer $r$ systematically calls stage onsets early or late. $C^r$ is a 5×5 row-stochastic matrix that captures threshold habits, such as calling borderline N1 as Wake. Both the offset distribution and the confusion matrix are allowed to depend on the input through a small head. That head reads local transition evidence, so a scorer's lag can differ between falling asleep and entering N3.
A third per-scorer component is a gate over channels. The gate lets scorer $r$'s confusion head read a reweighted view of the channel features. This tests the hypothesis that scorers differ in which signal they privilege, for example EOG eye-rolls versus EEG alpha at sleep onset. The consensus pathway $z$ never sees scorer identity.
The backbone is a U-Sleep-style fully convolutional encoder-decoder, which keeps the comparison with the strongest published DOD system clean. The cross-channel mixing it needs is a light attention layer over channel features at each time step. We avoid BSTT's variational graph inference because its ELBO approximations are costly and are not the point here.
Research Program
The work has three stages.
First, we fit the full model on DOD-H and DOD-O using all five scorers. We then inspect the per-scorer offset distributions and confusion matrices against directly measured scorer statistics. These include each scorer's mean signed boundary offset relative to the leave-one-out consensus of the other four, and each scorer's adjacent-stage confusion rates. This checks that the parameters mean what we claim they mean.
Second, we simulate the single-annotator regime. Each training recording keeps the labels of only one scorer, whose identity is known. We vary which scorer and how many recordings each scorer contributes. Evaluation is always against the consensus of scorers held out from that recording.
Third, we test deployment to an entirely new scorer. One scorer is held out from all training. We fit only that scorer's bias parameters on a small number of their labeled nights while freezing the consensus pathway. We then ask two things: whether the consensus predictions stay accurate, and whether the fitted parameters match that scorer's measured habits.
A secondary analysis repeats the channel-influence estimate of Channel Matters: Estimating Channel Influence for Multivariate Time Series (ChInf). ChInf is a first-order gradient influence measure showing how training on one channel affects loss on another. We compute it separately against each scorer's labels and against consensus. If channel rankings change by scorer, then channel-pruning decisions made on single-annotator data partly reflect the annotator rather than the physiology. ChInf did not consider this possibility.
Baselines
The naive reference is the same backbone trained with cross-entropy on whichever single scorer's labels are available, with no notion of scorer. This is what nearly every single-annotator sleep model does. Our method must beat it on consensus agreement in the simulated single-annotator regime or the idea fails.
The strongest existing method is U-Sleep itself. It reports macro F1 of 0.79 on DOD-H and 0.76 on DOD-O against consensus, the latter above every individual expert (0.69–0.74) (U-Sleep: resilient high-frequency sleep staging). Those numbers come from large-scale pretraining on 19,924 recordings with consensus-style evaluation. We will therefore run U-Sleep's architecture under our exact protocol: same DOD splits, same channels, same optimizer, same hyperparameter search budget, and with and without its public pretraining where available. The bias layer will be added to it rather than to a different backbone. Matching 0.76 on DOD-O while training on single-scorer labels would count as a win. Exceeding the matched single-scorer U-Sleep by a margin larger than the spread across random seeds would also count, especially in transition zones.
The key ablation removes the temporal offset distribution, setting $K=0$. This leaves a per-scorer, input-dependent confusion model, which is the standard crowd-labeling approach and the closest time-blind relative of TAB's style queries. A second ablation removes the channel gate. If the $K=0$ variant matches the full model, our temporal claim is false and the contribution reduces to known confusion-matrix methods. We would report that outcome as such.
We also run an upper reference: the backbone trained on mean soft labels from all five scorers. This shows how much of the multi-rater gain single-annotator training can recover. We found no reported result on Lacuna for confusion-matrix or soft-label training on DOD.
Why not just…?
Why not just train on the averaged soft labels from all five scorers? When five scorers exist, this is a real threat and may match our model on consensus F1. TAB's evidence that rater modeling beats consensus training comes from images, not sleep. We include soft-label training as the upper reference and expect it to be hard to beat in the five-scorer regime. The proposal's claim lives elsewhere. Almost all PSG archives have one scorer, so averaging is impossible. The question is whether a bias model fitted from single-scorer labels closes the gap to the soft-label reference, and the simulated single-annotator experiment measures exactly that gap.
Why not just learn a per-scorer confusion matrix, without any temporal component? This is the most natural simpler model and is our main ablation. Atcheson et al. found disagreement to be temporally correlated over seconds in continuous ratings, which suggests that bias in staging is partly about when a transition is called. A confusion matrix can only express what is called. Whether this transfers from emotion ratings to 30-second sleep epochs is unknown. The $K=0$ ablation, together with measured per-scorer boundary offsets, settles it directly.
Why not just smooth the predictions after the fact or score with a tolerance window around boundaries? Post-hoc smoothing such as Viterbi decoding removes flip-flopping. However, it does not tell you whose convention the smoothed hypnogram follows. U-Sleep also shows that brief transitions carry diagnostic information that smoothing erases. A tolerance window in evaluation hides scorer lag rather than modeling it. We report both smoothed baselines and tolerance-window metrics. If our gains disappear under a ±1-epoch tolerance, the bias we capture is "only" a lag. That is still useful to know, but it is a smaller claim.
Proposed Experiments
All experiments use DOD-H and DOD-O with recording-level cross-validation.
The primary metric is macro F1 against the consensus of held-out scorers. We also report three secondary measures. The first is F1 restricted to epochs within two epochs of a consensus boundary, which addresses the dilution problem SleepTSP identified. The second is boundary displacement error in seconds. The third is negative log-likelihood of the held-out scorers' empirical label distribution, which measures whether the model's uncertainty matches real disagreement.
The decisive checks are three. First, the fitted per-scorer offset distributions must correlate across scorers with independently measured mean boundary offsets on held-out nights. Offset distributions collapsing to zero would falsify the temporal-bias hypothesis. Second, in the single-annotator regime, the full model must beat both the naive single-scorer baseline and the $K=0$ ablation on transition-zone F1, beyond seed variance. Third, in the held-out-scorer test, fitting only bias parameters on a few nights must leave consensus F1 essentially unchanged while recovering that scorer's own labels better than the frozen consensus does.
If these hold, we apply the fitted pipeline to the single-scorer datasets ISRUC-S3 and Sleep-EDF-78 as an exploratory check. We will not have ground-truth panels there. Instead, we ask whether the inferred scorer offsets are nonzero and whether ChInf channel rankings shift once the scorer layer is removed.
References
- U-Sleep: resilient high-frequency sleep staging
- Demonstrating and Modelling Systematic Time-varying Annotator Disagreement in Continuous Emotion Annotation
- Transformer-Based Annotation Bias-Aware Medical Image Segmentation
- BSTT: A Bayesian Spatial-Temporal Transformer for Sleep Staging
- SleepSMC: Ubiquitous Sleep Staging via Supervised Multimodal Coordination
- Stage Prototypes for Transition-Aware Temporal Modeling in Single-Channel Sleep Staging
- Channel Matters: Estimating Channel Influence for Multivariate Time Series