Separating Scan Quality from Reader Style in Medical Measurement

When several experts outline the same organ or tumor on a scan, they disagree. Some of that disagreement is personal style: one radiologist habitually draws a tight boundary, another a generous one. Some of it comes from the image itself: on a noisy, blurry or low-field scan, nobody can see where the boundary is, so everyone guesses differently. Current models of annotator disagreement, which treat each expert as a point in a learned "style space," fold both sources into one quantity. That matters in practice. If a fetal brain measurement is uncertain because the readers differ in style, the fix is a second reader or a protocol. If it is uncertain because a 0.55-tesla scanner produced a degraded image, the fix is a rescan. Today's systems cannot say which applies.

We propose a segmentation model with two separate sources of variation. The first is a per-reader style offset that is not allowed to depend on the image. The second is a shared ambiguity term whose size is predicted from measured acquisition quality. The idea comes from robustness work in biometrics, the field of identifying people or measuring bodies from sensor data. There, sensor and environment degradation is modeled explicitly as its own noise source rather than absorbed into the identity signal. We also run the first controlled re-annotation study that tests the separation directly: do readers keep their style when image quality drops, and does their shared disagreement grow in proportion to the degradation? The model's main output is a measurement with an uncertainty interval split into a "reader" part and a "scan" part. Examples are a fetal brain biometric or a nodule diameter.

Core Claim

Reader style is roughly invariant to acquisition quality, while disagreement shared across readers grows with physical degradation. A model built on this structure will produce uncertainty intervals on measurements that stay calibrated under domain shift. It will also tell clinicians whether to rescan or re-read. Models that learn one combined reader-uncertainty space cannot do either.

Two findings motivate the claim. The FeTA 2024 challenge (Advances in automated fetal brain MRI segmentation and biometry: Insights from the FeTA 2024 challenge) benchmarked fetal brain segmentation and biometry, meaning measurements extracted from those segmentations, across sites and field strengths. It found that image quality alone moved Dice by about 0.10 and acquisition site by about 0.075. Its best biometry model reached 7.72% mean absolute percentage error (MAPE), against 5.38% for human inter-rater variability and 9.56% for a gestational-age-only baseline. Automated measurement is therefore still well outside human precision, and degradation is a major driver of error. However, the challenge reports human variability as a single number and never asks how it changes with scan quality.

The biometrics side supplies the modeling stance. WiFaKey (WiFaKey: Generating Cryptographic Keys from Face in the Wild) treats unstable face features under bad lighting and pose as a separable noise channel and masks the volatile bits before decoding. Palm-vein compression studies (Empirical Study of Image Compression for Palm Vein Recognition) show that sensor artifacts interact with some feature types and not others. We borrow the stance, not the code: quality-driven volatility should be modeled as its own channel, separate from the stable signal. Here the stable signal is reader style rather than identity.

Research Program

The model starts from the observer-latent design of Pionono (Probabilistic Modeling of Inter- and Intra-observer Variability in Medical Image Segmentation). Pionono gives each rater a Gaussian latent, where the mean encodes systematic bias and the variance encodes the rater's own inconsistency. It reached a Cohen's kappa of 0.758 on Gleason 2019. Pionono's latent depends only on the rater, so any extra disagreement caused by a bad image has to be absorbed either into the rater variances or into the shared decoder. We add a second, image-conditioned latent. A segmentation sample for reader $r$ on image $x$ is

$$ y \sim D\big(x,\; z_r + \sigma(q(x))\,\epsilon\big), \quad z_r \sim \mathcal{N}(\mu_r, \Sigma_r),\; \epsilon \sim \mathcal{N}(0, I), $$

where the symbols are defined as follows. $D$ is a U-Net decoder. $\mu_r$ and $\Sigma_r$ are reader $r$'s style mean and self-inconsistency. $q(x)$ is a vector of acquisition-quality descriptors: estimated noise level, blur, and field strength or site when known. $\sigma(\cdot)$ is a small network giving the scale of the shared ambiguity term. Two constraints enforce the separation. First, $\mu_r$ and $\Sigma_r$ receive no image input. Second, an adversarial penalty stops the quality descriptors from predicting reader identity and stops reader latents from predicting quality. Measurements such as biometric distances or nodule diameter are computed on each sampled mask. Splitting the variance of those measurements between the reader term and the scan term gives the two-part interval.

The model is not useful unless the separation holds in real readers, so the second component is an annotation study. We take subsets of LIDC-IDRI CT nodules and of FeTA fetal MRI. Each case is shown to the same three to four readers twice, once at native quality and once with calibrated degradation: added noise, thicker slices or downsampling that mimics low dose or low field, and compression. Reading order is randomized and separated by a washout period. For FeTA, the 0.55T King's College London (KCL) cases provide real low-field degradation alongside the synthetic kind. The study answers three empirical questions. Does each reader's offset relative to the panel stay put across quality levels? Does the panel's shared spread grow with degradation? Does any reader change style when the image is bad, for example by becoming more conservative? A yes to the third question would falsify the core assumption. In that case we would let $\mu_r$ depend on $q(x)$ through a low-rank interaction term and report that as the finding.

Baselines

The naive reference point is a single nnU-Net, the self-configuring U-Net that dominated FeTA, trained on majority-vote or STAPLE consensus labels with heavy augmentation. Its uncertainty comes from test-time augmentation. This is what most deployed pipelines do, and the FeTA leaders used essentially this recipe. The strongest reported number on this question is the best FeTA 2024 biometry MAPE of 7.72%, set against 5.38% human inter-rater MAPE (FeTA 2024). We will retrain this baseline on our splits rather than quote it, because our re-annotated subset differs from the challenge test set.

The strongest existing multi-reader methods are Pionono, which is our model with the image-conditioned term removed, and ProSona (ProSona: Prompt-Guided Personalization for Multi-Expert Medical Image Segmentation). ProSona steers a probabilistic U-Net with text prompts describing rater style and reports a 17% lower generalized energy distance (GED) than DPersona on LIDC-IDRI. GED measures how closely a set of sampled masks matches the set of expert masks. The file gives this only as a relative improvement, not an absolute GED. We also include the Latent Doctor Model (The Latent Doctor Model for Modeling Inter-Observer Variability), a conditional variational autoencoder that infers a doctor's style from a set of that doctor's annotations; its reported KL divergence on Gleason 2019 is 0.461. We include MoSE (Modeling Multimodal Aleatoric Uncertainty in Segmentation with Mixture of Stochastic Experts), a mixture of stochastic expert decoders whose GED improvements on LIDC-IDRI are reported without absolute values in the file. Finally, we include a deep ensemble with one model per reader.

All methods share the same backbone width, training data, augmentation policy and a fixed hyperparameter search budget of equal GPU-hours. Where feasible all are evaluated in 3D. ProSona was published on 2D slices, so we run it slice-wise and say so.

The key ablation removes the adversarial separation penalty while keeping the image-conditioned branch. Without the penalty, any gain could just come from extra capacity. With the penalty, a gain means the model is using the separation itself.

Beating the baselines means three things on the degraded strata and the real 0.55T strata. First, interval coverage of held-out reader measurements must be closer to nominal. Second, GED and biometry MAPE must be no worse. Third, the predicted reader/scan split must agree with the variance split observed in the annotation study.

Why not just…?

Why not just augment heavily and let nnU-Net absorb the degradation? Augmentation teaches a single mask to resist noise. It does not predict how much readers would disagree, and it cannot attribute uncertainty to the scan. FeTA itself shows that heavily augmented nnU-Nets remain above human measurement error (7.72% versus 5.38% MAPE) and show large topology differences at equal Dice. Our coverage-by-quality-stratum analysis will show directly whether test-time-augmentation intervals widen correctly on degraded scans.

Why not just use Pionono or ProSona and let the latent soak up quality effects? This is the most direct competitor. Nothing in those models prevents a reader latent from encoding "reader seen on site A," which mixes site with style when readers and sites are confounded, as they are in most real datasets. The ablation without the image-conditioned branch, evaluated on the annotation study, decides the question. If Pionono's per-reader variances already track quality stratum and its intervals are equally calibrated, our structural claim adds nothing and we will report that.

Why not just regress interval width on an image-quality score after the fact? This is a real threat. A two-stage calibration that predicts measurement spread from quality descriptors, fit on the annotation study, may match our model on interval coverage for scalar biometrics. It cannot say where in the image the ambiguity sits, and it cannot separate reader offset from shared spread for a new reader. We run it as a baseline. If it matches us on coverage and the reader/scan split, the contribution shrinks to the annotation study and the empirical invariance finding, which we would then present as the main result.

Why not just train a deep ensemble, one model per reader? Ensembles capture reader differences but have no handle on degradation beyond their shared training. The Latent Doctor Model and MoSE both report matching or beating ensembles with a single network at far lower parameter cost: about 9.37M for MoSE-light versus about 175M for adversarial alternatives. We keep the ensemble as a fairness check on coverage.

Proposed Experiments

Phase one runs on LIDC-IDRI, whose four radiologists annotated every nodule. Synthetic degradation at three severities lets us control quality exactly. We train on native-quality annotations, then test against the re-annotated degraded subset. Metrics are GED, per-reader Dice, nodule-diameter interval coverage, and the correlation between predicted and observed scan-share of variance.

Phase two moves to FeTA. We train on high-field KISPI and Vienna data and test on the 0.55T KCL set. The metrics are biometry MAPE, measurement-interval coverage against the re-annotated readers, and Euler characteristic difference as a topology check across sampled masks.

The decisive checks are four. Reader style offsets estimated at native quality must predict the same readers' offsets at degraded quality; we report correlation, and this is the falsification test. Predicted shared spread must increase monotonically with degradation severity and match the observed increase. On 0.55T scans, intervals must keep nominal coverage where the baselines under-cover. Removing the separation penalty must erase the gain. If the first check fails, we report how readers change under degradation, which is itself unmeasured in current work, and revise the model accordingly.