A short-axis cardiac MRI scan is not a 3D movie. It is a stack of 2D movies, one per slice, and each slice is recorded during its own breath-hold. Every slice video shows a full heartbeat sharply, but the patient holds their breath at a slightly different depth each time, so neighbouring slices are shifted relative to one another. Stacked naively, the heart shows "staircase" steps along its walls. Current tools handle this in two separate steps. A slice-alignment step first estimates each slice's shift. A motion-tracking network then assumes the stack is already coherent. The two kinds of motion are mixed in the data, so an error in the first step is read by the second as real heart deformation.
We propose to estimate both kinds of motion jointly, from a short-axis stack alone, by splitting the scan into three factors. The first is a fixed 3D anatomy. The second is a heartbeat deformation that is shared by all slices at each cardiac phase. The third is a rigid shift per slice that stays the same across all phases of that slice's breath-hold. The structure that makes this split possible is a feature of the acquisition that existing methods ignore. Breath-hold jitter depends only on the slice index, heart motion depends on the cardiac phase, and the anatomy depends on neither. A second ingredient handles tissue that moves into and out of the thin imaging plane, such as the base of the ventricle crossing the valve plane during contraction. We model this explicitly as a visibility effect, rather than letting the network explain it as tissue appearing and vanishing.
Core Claim
The claim has two parts. First, a model that shares one rigid shift per slice across the whole cardiac cycle, and estimates it jointly with a smooth heartbeat deformation, will recover jitter and 3D myocardial motion more accurately than a sequential pipeline. Second, this holds without the long-axis anchor views that current multi-view trackers require. The closest existing work is MulViMotion. It tracks 3D myocardial motion with a 2D-feature/3D-convolution network, using a shape branch for weak supervision. It needs calibrated long-axis views and assumes the short-axis stack shares one reference frame. This is the assumption the research file reports it flagging as broken under respiratory staircasing.
Predictive slice-to-volume methods do the opposite job. SVoRT uses a transformer that treats slices as a sequence and alternates between estimating slice poses and updating the volume. The fully convolutional Splat-Slice U-Net predicts per-slice motion in one pass, using splatting and slicing operators placed inside the network. Both assume a rigid brain and contain no deformation model. Our proposal borrows the splat/slice operators and the loss that ignores global rigid motion from Young et al. It differs from all three by making the time-invariance of jitter a hard structural constraint, inside one model that also explains deformation.
The forward model we fit is short enough to state. Let $A$ be the static canonical anatomy at end-diastole. Let $\phi_t$ be the heartbeat deformation at phase $t$. Let $R_k$ be the rigid transform of slice $k$, which is constant over $t$. Let $P$ be the through-plane slice profile, modelled as a Gaussian. Let $S_k$ be the operator that extracts the plane of slice $k$. Then the observed slice image or segmentation $I_{k,t}$ should satisfy
$$ I_{k,t} \approx S_k\big(R_k \circ [\,P * (A \circ \phi_t^{-1})\,]\big). $$
A deformation $\phi_t$ that is smooth across slices cannot mimic a shift that jumps from slice to slice but is constant over time. The time axis therefore separates jitter from heartbeat motion.
The anatomy $A$ is also constant over time, so jitter and the true tilt of the heart along its long axis are not separated by time. We separate them with smoothness of the anatomy along the long axis, which a population-level 3D convolutional prior supplies. When long-axis views exist, we use them only for evaluation, never as input. We state this confound openly because it is the main way the method could fail.
Research Program
The network has three parts.
- Jitter head. A 3D convolutional encoder processes each phase's stack. A jitter head pools these features over all phases and predicts one in-plane rigid transform, plus a small through-plane offset, per slice. This pooling over time is where the decoupling happens. It follows the spirit of dual-encoder content/motion splits such as DRNET, but with the split dictated by the scanner's acquisition order rather than learned through adversarial losses.
- Motion network. The slice features are splatted into a 3D grid at their de-jittered positions. A 3D convolutional motion network then predicts $\phi_t$ from end-diastole. 3D convolution is a sensible choice only after this step. As C3D and the file's analysis of 3D kernels make clear, these kernels assume continuity along the third axis, and staircasing breaks that assumption.
- Anatomy and rendering. The anatomy $A$ is compositional, with separate occupancy for left-ventricular blood pool, myocardium and right ventricle. Rendering uses an analytic Gaussian slice profile, adapted from the covariance-summation trick in GSVR.
The occlusion ingredient enters in two places. First, the renderer integrates over the slab. Basal myocardium that leaves the slab at end-systole is therefore explained by $\phi_t$ moving tissue out of plane, rather than by a deformation that tears or shrinks tissue. This targets the homeomorphism limitation that the file attributes to Occupancy Flow, which assumes geometry deforms continuously without topology change. Second, the gaps between thick slices are regions no slice observes. There we impose a non-penetration penalty between adjacent structures, so that the observed boundary of one structure constrains the unobserved boundary of its neighbour. This is the "contact mold" idea that HOLD uses for hands and objects, moved from camera occlusion to unsampled tomographic gaps. We treat this as a secondary regularizer, not the headline.
Training combines three signals:
- a self-supervised term requiring rendered slices to match observed segmentations,
- MulViMotion-style weak supervision from sparse 2D contours,
- a synthetic-jitter term, in which known rigid shifts are injected into stacks that already have low staircasing, and the model must recover them.
Baselines
The naive reference is no jitter correction at all: MulViMotion's motion network run on the raw short-axis stack with long-axis inputs removed. This measures how much staircasing actually costs.
The strongest existing motion method is MulViMotion with its long-axis views. On UK Biobank it reports Dice 0.82, against 0.73 for a 3D U-Net and about 0.72 for free-form deformation and Demons. It also reports a Hausdorff distance of 14.59 mm and a volume difference of 8.62%. We will retrain it on our exact UK Biobank split, with the same epochs and hyperparameter search budget as our model. Our method beats it if, using short-axis input only, it matches its Dice and Hausdorff distance within confidence intervals and improves volume preservation. A clear win requires that the gap holds or widens as injected jitter grows.
The strongest sequential pipeline is a slice-alignment front end followed by MulViMotion. For the front end we use the learning-based inter-slice correction of Tarroni et al.. If that code is unavailable, we use a Splat-Slice U-Net retrained on cardiac end-diastolic frames. No reported cardiac result was found on Lacuna for either as a front end. We report jitter recovery error in millimetres alongside the motion metrics.
For basal-slice segmentation on ACDC, the reference is CSTM. It reports basal Dice 0.931 against STCN's 0.916.
Ablations isolate each ingredient:
- letting the jitter head predict a separate shift per phase, which removes the time-sharing constraint;
- replacing the compositional slab renderer with a single occupancy field and point sampling, which removes the visibility model;
- removing the non-penetration term.
Why not just…?
Why not just correct slices first, then track motion? This is the real threat. If jitter estimated at one phase is already nearly perfect, joint modelling adds little. The sequential approach estimates shifts from roughly one frame per slice, while our jitter head pools about 50 frames per slice. Its errors also pass silently into the motion field. The injected-jitter experiment settles the question directly. If two-stage jitter error matches ours, and motion metrics are equal at every jitter magnitude, the joint claim fails and we would report that.
Why not just align the left-ventricle centre of mass slice by slice? Centroid alignment cannot tell jitter apart from the genuine tilt of the heart along its long axis, because both are constant across phases. It also ignores rotation. We include it as an additional baseline. We expect it to over-correct anatomically tilted hearts, which we will check by comparing against held-out long-axis intersections.
Why not train one large network with jitter augmentation and no factorization? A monolithic 3D network might learn the invariance implicitly. The per-phase-jitter ablation, trained with identical augmentation, tests this. If it matches the shared-jitter model, the structural constraint is unnecessary and the contribution shrinks to the renderer.
Proposed Experiments
Simulation. We select UK Biobank subjects whose short-axis/long-axis intersection agreement indicates low native jitter. We inject rigid shifts of 0–8 mm and 0–5 degrees per slice, constant across phases, and measure jitter recovery error and motion-field change relative to the uncorrupted run.
Real data. On real stacks we use the held-out long-axis views to measure how far the corrected short-axis stack's intersection profiles deviate from them. For motion accuracy we report Dice, Hausdorff distance and volume difference following MulViMotion's protocol, and on ACDC we report basal Dice against CSTM.
Decisive checks. Two results decide the claim. Our motion metrics should stay flat as injected jitter grows, while the naive and sequential pipelines degrade. And the shared-jitter model should beat its per-phase ablation on jitter error at equal compute. If either fails, the joint factorization claim is not supported.
References
- MulViMotion: Shape-Aware 3D Myocardial Motion Tracking From Multi-View Cardiac MRI
- SVoRT: Iterative Transformer for Slice-to-Volume Registration in Fetal Brain MRI
- Fully Convolutional Slice-to-Volume Reconstruction for Single-Stack MRI
- Unsupervised Learning of Disentangled Representations from Video
- Learning Spatiotemporal Features with 3D Convolutional Networks
- Fast and Explicit: Slice-to-Volume Reconstruction via 3D Gaussian Primitives with Analytic Point Spread Function Modeling
- Occupancy Flow: 4D Reconstruction by Learning Particle Dynamics
- HOLD: Category-Agnostic 3D Reconstruction of Interacting Hands and Objects from Video
- A Comprehensive Approach for Learning-Based Fully-Automated Inter-slice Motion Correction for Short-Axis Cine Cardiac MR Image Stacks
- Continuous Spatio-Temporal Memory Networks for 4D Cardiac Cine MRI Segmentation