When several radiologists outline the same lung nodule on a CT scan, they often disagree. Recent models stop averaging those outlines away. Instead they learn to produce the whole spread of plausible expert outlines. These models are trained and judged on datasets where most cases are easy: small, round nodules that every rater draws almost identically. The cases where experts genuinely diverge, such as spiculated edges, nodules touching vessels or pleura, and lesions that some raters do not mark at all, are rare. They are also the cases clinicians care most about. Class-imbalance methods address rarity, but they rebalance by the diagnostic label ("malignant" versus "benign"), which is the wrong axis here.
This note proposes rebalancing training data along the axis of disagreement itself. Each nodule is grouped into strata by how much its raters disagree. The rare high-disagreement stratum is then oversampled, either by resampling real cases or by generating new 3D nodules together with a whole synthetic panel of rater outlines. Everything is done natively in 3D, so that a simulated "conservative rater" outline stays consistent from slice to slice. The test is whether a model trained this way reproduces expert disagreement better on the ambiguous tail without degrading the easy majority. A second test is whether doing so amplifies the known tendency of radiologists to over-call malignancy.
Core Claim
In multi-rater volumetric data, the underrepresented regime that limits current models is defined by annotation disagreement, not by class label. Two things follow. Oversampling by class label, the default use of SMOTE-style methods that interpolate between minority examples, targets the wrong cases. Oversampling by disagreement stratum should improve how well predicted outline sets match human outline sets on high-disagreement nodules. We further claim that when real high-disagreement cases are too few to resample without overfitting, synthetic cases help only if the synthetic rater panel is generated jointly and in 3D. Synthetic cases paired with a single consensus mask, or synthesized slice by slice, should not help. Each part of this claim has a matching ablation below. The claim fails outright if disagreement-stratified sampling does no better than class-stratified sampling on the tail.
Why this intersection, and what already exists
The multi-rater modelling side supplies the method. Three approaches each represent the spread of expert opinion with a random latent variable. Mixture of Stochastic Experts uses several random decoder branches trained with an optimal-transport loss so that the set of predicted masks matches the set of LIDC-IDRI annotations. Pionono gives each rater a Gaussian in a small latent space, whose mean encodes that rater's bias and whose variance encodes their inconsistency. The Latent Doctor Model infers a rater's style from a support set of their past annotations. All three work on 2D images or 2D nodule crops, and none addresses imbalance. UGS-Net comes closest on LIDC-IDRI. It trains separate branches on the union, intersection, and individual rater masks to mark high- and low-confidence zones. It still treats all nodules uniformly and works on slice representations. We reuse the latent-variable idea, lift it to 3D crops, and change what the model sees during training rather than its architecture.
The imbalance side both motivates and constrains the design. Conditional PGGAN augmentation for brain metastases conditioned a generator on rough boxes and raised detector sensitivity from 0.67 to 0.77 with 4,000 synthetic images. The same paper saw false positives spike at 12,000 synthetic images and states that its 2D slice synthesis lacks cross-slice constraints. Surgical Imagen showed that oversampling rare categories during diffusion training was needed to generate them at all. Both condition on one deterministic label. Work on intra-class imbalance argues that minority classes are not homogeneous, which is exactly our point: within the "nodule" class, the hard subpopulation is the ambiguous one. The false-positive spike constrains us to treat the synthetic fraction as a swept variable, not a fixed choice.
Two results frame the risk. Re-thinking and Re-labeling LIDC-IDRI showed that radiologists over-score ambiguous nodules for safety. A 3D ResNet trained on their consensus reached 0.97 sensitivity but 0.23 specificity. Propagating biopsy labels from the 180-nodule SCH-LND set restored 0.67/0.66. Because high-disagreement nodules are where this bias concentrates, oversampling them could make things worse. We therefore measure the bias explicitly rather than assume it away. More is more found that keeping all raters in a virtual panel beat both consensus and "best-rater" panels. That supports our choice to preserve every rater's outline rather than reweight raters by downstream diagnostic value, as DiFF does.
The local-global trade-off enters as a constraint on the backbone, not as the contribution. Disagreement on LIDC nodules comes in two kinds. Margin disagreement is a few voxels of boundary. Structural disagreement is whether an attached vessel or spiculation belongs to the nodule, a question that can only be settled by following the structure across slices. The first is local; the second needs volumetric context. We use a hybrid 3D backbone with convolutions for local detail and a depthwise-convolutional attention stage for wider context, in the spirit of the Fully Convolutional Transformer, whose authors call for a native 3D extension. We then report gains separately for the two disagreement kinds.
Research Program
The first step is to define strata. For each LIDC-IDRI nodule we compute a disagreement score: the mean pairwise one-minus-IoU among available rater masks, where a rater who did not mark the nodule counts as an empty mask. This choice matters, because non-marking is the most extreme form of disagreement and is usually discarded. We also label each high-disagreement nodule as margin-type or structure-type. The rule is whether the symmetric difference between rater masks lies mostly within a thin shell around the intersection mask, or forms connected components extending across three or more slices. We will report the stratum sizes and their overlap with malignancy scores. That overlap test is itself the first check on the core claim: if high disagreement is just a proxy for high malignancy score, class-based and disagreement-based rebalancing collapse into the same thing.
The base model is a 3D multi-rater segmenter on 64-voxel cubic crops centred on each nodule. It uses the hybrid backbone above and a MoSE-style decoder: a few random experts, each with a latent sample drawn once per volume, trained with the optimal-transport set loss. Drawing the latent once per volume guarantees that a simulated rater's style is shared by all slices of that nodule.
Rebalancing is tested at two levels of intervention. The cheap level resamples real nodules so that each disagreement stratum contributes equally to each batch. The expensive level adds synthetic high-disagreement nodules. For synthesis we separate the outline panel from the image. A small 3D diffusion model (a generator that learns to turn noise into samples by gradual denoising) produces a set of four binary rater masks, conditioned on a target disagreement score and type. A second 3D generator then produces the CT crop, conditioned on the soft average of those masks, so that voxels with partial agreement become partial conditioning. This follows the mask-conditioned synthesis of the PGGAN work, adapted to 3D using the wavelet approach of WDM. Synthetic cases are admitted only if a nodule classifier trained on real data accepts them, and the synthetic fraction is swept from zero up to three times the real tail size.
Baselines
The naive reference is a 3D nnU-Net-style segmenter trained on the majority-vote mask. Its disagreement coverage is measured by sampling nothing: it produces one mask, which is scored against the panel. It shows how much any multi-rater modelling buys before rebalancing enters. The published anchor on this data is UGS-Net at an average Dice of 86.12%, IoU of 76.44%, and NSD of 95.36% on 1,859 LIDC-IDRI nodules (UGS-Net). We report our Dice against its protocol for comparability, but this is not the metric our claim rests on.
The strongest competitor is MoSE (Mixture of Stochastic Experts), because it directly targets matching the set of LIDC annotations and is parameter-efficient. We run it in its original 2D crop form and lifted to our 3D backbone. Both versions use identical splits, crop sizes, total training steps, and a matched hyperparameter search budget. The file reports that MoSE lowers generalized energy distance (GED, a distance between the set of predicted masks and the set of human masks) against PHiSeg and Probabilistic U-Net, but no reported GED value for MoSE on LIDC-IDRI was found on Lacuna. We will therefore re-run it ourselves and treat our reproduced number as the bar. Beating it means a statistically reliable GED reduction on the top disagreement tertile, measured with bootstrap confidence intervals over nodules, with no significant loss on the bottom tertile.
Class-stratified oversampling is the direct test of "rebalance by disagreement, not label." It applies the same resampling budget to the base model, with strata defined by median malignancy score instead of disagreement. Two ablations isolate the synthesis ingredients under the same synthetic budget. The consensus-synthetic ablation pairs each generated image with only its majority-vote mask. The slice-synthetic ablation generates the same cases with a 2D generator applied slice by slice.
Why not just…?
Why not just use a 2D multi-rater model and sample the rater latent once per nodule? This is the most serious threat to the 3D part of the proposal. Drawing one latent per nodule already removes much of the slice-to-slice jitter in rater style, the failure described for slice models in pancreas segmentation. We include exactly this 2.5D baseline, with adjacent-slice input and a tied latent. Our prediction is that it matches the 3D model on margin-type disagreement but not on structure-type disagreement, where whether a vessel belongs to the nodule depends on following it through depth. If it matches on both, we drop the 3D claim and keep the rebalancing result.
Why not just reweight the loss or resample real hard cases instead of generating new ones? Resampling real cases is built into the program as the cheap intervention, not treated as a straw man. The high-disagreement tail on LIDC-IDRI may simply be too small to resample without memorization. Only in that case should synthesis add value, and the synthetic-fraction sweep will show whether it does. If real resampling matches synthesis, the contribution is the stratification itself, and we will report it that way. Pure loss reweighting by stratum is run as a third variant at matched effective weights.
Why not just train on the consensus mask and add test-time augmentation or an ensemble for uncertainty? Consensus training has been shown to miscalibrate: ECE of 0.183 against 0.050 for a multi-rater panel in More is more. Ensembles over seeds spread predictions for reasons unrelated to how experts disagree. A seed ensemble of the naive baseline, at matched compute, is included and scored on GED, so this claim is tested rather than asserted.
Proposed Experiments
All experiments use LIDC-IDRI nodules with patient-level splits and five-fold cross-validation. Evaluation is always stratified by disagreement tertile and by disagreement type. The primary metric is GED between sampled and human mask sets. Secondary metrics are Hungarian-matched IoU (pairing each predicted mask with its best-matching human mask), voxel-level calibration of the predicted agreement fraction against the actual fraction of raters marking each voxel, and a slice-coherence score: the rate of large area jumps between consecutive slices within a single sampled mask.
The first decisive check is whether disagreement-stratified sampling beats class-stratified sampling on the top tertile. If it does not, the core claim is falsified. The second is the three-way comparison of real resampling, joint-panel 3D synthesis, and the two synthesis ablations along the synthetic-fraction sweep. We watch for a PGGAN-style degradation at high fractions, measured as rising false-positive voxel volume on the easy tertile.
The third check concerns bias. A downstream malignancy probe is trained on features from each segmenter using LIDC ratings, then evaluated on biopsy-confirmed SCH-LND nodules. We compare its sensitivity and specificity against the 0.97/0.23 consensus and 0.67/0.66 re-labeled operating points reported by Re-thinking and Re-labeling LIDC-IDRI. If disagreement oversampling pushes specificity down toward the consensus figure, the method is reproducing radiologists' safety-first bias more faithfully rather than getting closer to biology. That outcome would be worth publishing as a caution, and it would argue for pairing the method with biopsy anchoring.
References
- SMOTE: Synthetic Minority Over-sampling Technique
- Modeling Multimodal Aleatoric Uncertainty in Segmentation with Mixture of Stochastic Experts
- Probabilistic Modeling of Inter- and Intra-observer Variability in Medical Image Segmentation
- The Latent Doctor Model for Modeling Inter-Observer Variability
- Uncertainty-Guided Lung Nodule Segmentation with Feature-Aware Attention
- Learning More with Less: Conditional PGGAN-based Data Augmentation for Brain Metastases Detection Using Highly-Rough Annotation on MR images
- Surgical text-to-image generation
- Towards Inter-class and Intra-class Imbalance in Class-imbalanced Learning
- Re-thinking and Re-labeling LIDC-IDRI for Robust Pulmonary Cancer Prediction
- More is more: leveraging multi-rater information for whole slide images grading via virtual expert panel
- Calibrate the Inter-Observer Segmentation Uncertainty via Diagnosis-First Principle
- The Fully Convolutional Transformer for Medical Image Segmentation
- WDM: 3D Wavelet Diffusion Models for High-Resolution Medical Image Synthesis
- Deep convolutional networks for pancreas segmentation in CT imaging