Radiotherapy for head and neck cancer is planned once, on a scan taken before treatment, and then delivered in about 30 daily sessions. Over those weeks the patient loses weight and the tumor shrinks. The same beams then deliver more dose to healthy organs such as the salivary glands and less to the target. Replanning fixes this but costs days of clinical labor. Clinics therefore replan reactively, when the change is visible, or by a fixed dose rule. New software can now estimate each day's delivered dose from the routine on-board scan in under a minute, so the measurement is no longer the bottleneck. The decision is. Nobody has asked which trigger rule gives the most health per dollar. Existing trigger studies also rest on a few dozen patients, which makes any learned rule, and any cost claim built on it, fragile.
We propose to treat the replanning trigger as an economic decision made under uncertainty. At each session, a small hierarchical Bayesian model forecasts where the patient's accumulated dose is heading. The model separates day-to-day setup noise from true anatomical drift and borrows strength across patients, which matters because cohorts are tiny. The forecast feeds a rule that replans only when the expected health gain, valued at a willingness-to-pay threshold, exceeds the cost of replanning. The same model also reports the value of collecting more patients. This turns "small sample size" from a disclaimer into a number: how much a larger study would be worth.
Core Claim
A replanning trigger should be tuned and judged by net monetary benefit per patient. Net monetary benefit is the QALYs gained times the willingness-to-pay per QALY, minus the added cost. It is the rearranged form of the incremental cost-effectiveness ratio (ICER), the extra cost per extra quality-adjusted life year that Zhang and Griffin formalize. Trigger quality should not be measured by dosimetric thresholds alone.
With cohorts of around 27 patients, the rule that maximizes this benefit must account for two things fixed thresholds ignore. The first is that early dose violations are largely transient setup error. The second is that forecasts made from a handful of sessions are highly uncertain.
We claim that a partially pooled forecaster combined with an expected-benefit decision rule yields higher benefit than both current practice and dosimetric thresholds. We also claim it produces the first ICER estimates for automated adaptive radiotherapy triggers, along with a principled estimate of how many more patients are needed before those estimates can be trusted.
Why this gap is real
Two studies show that rapid triggers are technically feasible.
RTapp decision-support evaluation deforms the planning CT and dose onto daily cone-beam CT (CBCT, the low-quality 3D scan taken on the treatment machine) in under a minute. On 27 patients it found that 67% violated a dose constraint and that parotid glands gained a median +2.60 Gy. It forecasts four sessions ahead by linear regression, with mean errors of −2.7% for PTV coverage (PTV is the planning target volume, the tumor plus a safety margin) and 0.3 Gy for parotid mean dose. It also documents two problems a simple trend line cannot handle. The first is a "two-phase" pattern in which violations in sessions 1–6 are driven by setup variation rather than shrinkage. The second is wide confidence intervals from the small cohort.
The stepwise HU-to-density study calculates dose directly on CBCT. HU, or Hounsfield units, are the intensity values in a CT scan. It reports that CBCT-predicted changes in PTV D2% correlate with rescanned CT at r = 0.93. Using a 3% threshold, 7 of 12 replanned patients could have skipped replanning. The 3% was chosen by convention, not by cost.
Neither study prices its decisions. On the economics side, the AI precision-medicine value review motivates the work in three ways. It found precision-treatment tools in only 2% of 48 economic evaluations, and adaptive radiotherapy in none. It found that assuming full clinician compliance inflates value. It also found that 63% of evaluations never show their conclusions transfer across sites. We adopt all three findings as design constraints.
Research Program
Forecaster. For patient $i$ at session $t$, we model an observed dose metric, such as parotid mean dose or PTV D95%, as
$$d_{i,t} = a_i + b_i\, g(t) + s_{i,t},$$
where $a_i$ is the patient's planned-dose offset, $b_i$ is their drift rate along a shared shape $g(t)$ of anatomical change, and $s_{i,t}$ is setup noise. We model $s_{i,t}$ as autocorrelated over a few sessions but not persistent. The patient terms $a_i, b_i$ are drawn from population distributions, so a new patient with three sessions of data is pulled toward the cohort, and this is the partial pooling. The shape $g(t)$ is informed externally by tumor-volume change between pre- and mid-treatment MRI across 150 patients in the HNTS-MRG 2024 data used by the MA-SegResNet longitudinal segmentation work and the nnUNet/MedNeXt comparison. Those papers supply segmentation; we reuse their volume trajectories as a prior. The output is a posterior predictive distribution of end-of-treatment accumulated dose under "continue" versus "replan now."
Decision rule. Dose is mapped to complication probability through a delivered-dose xerostomia model, following the actual-delivered-dose parotid study, and target underdose is mapped to control loss. Those probabilities enter a small Markov model of toxicity, recurrence, and death states, built in the style supported by OpenMarkov. At session $t$ we replan if
$$\lambda\, \mathbb{E}[\Delta Q_t] - c_{\text{replan}} - \lambda\, \mathbb{E}[\Delta Q_{\text{wait}}] > 0,$$
where $\lambda$ is willingness-to-pay per QALY, $\Delta Q_t$ is the QALY gain from replanning now, $c_{\text{replan}}$ is the labor and imaging cost scaled by an adherence probability, and $\Delta Q_{\text{wait}}$ is the gain from deferring, which is the value of waiting for more data. This follows the logic of cost-sensitive causal decision-making. That paper shows that ranking by expected profit rather than raw treatment effect is optimal, but only for binary outcomes in marketing data. We extend it to sequential, continuous-dose, QALY-valued decisions.
Value of more data. From the same posterior we compute the expected value of sample information: how much net monetary benefit per future patient a cohort of $N$ additional patients would buy. This differs from entropy removal per dollar, which scores static tests by uncertainty removed. We value information by the decisions it changes.
Transfer. We rerun the whole analysis at GDP-scaled thresholds, following Kuntjoro et al., and at different labor costs. The goal is to see whether the optimal rule changes, which directly tests the transferability gap.
Unlike operator-splitting adaptive radiotherapy, which re-optimizes the dose itself under assumed health dynamics on a single case, we leave planning untouched and optimize only when to intervene.
Baselines
Current practice. The naive reference is no replanning, together with the common protocol of a fixed replan at a set session near mid-treatment. Both are evaluated under the same Markov model and costs. Beating these references means positive incremental net monetary benefit at $150,000/QALY, the US threshold cited via the pembrolizumab melanoma analysis.
Strongest existing method. The strongest dosimetric trigger is RTapp-style linear four-session forecasting with constraint-violation alerts, combined with the 3% PTV D2% rule of the stepwise HU study. Its reported numbers are the −2.7% coverage and 0.3 Gy parotid forecast errors, and 7/12 replans avoided. For economic outcomes, there is no reported result on Lacuna for the net monetary benefit or ICER of any adaptive radiotherapy trigger; we compute it ourselves under identical inputs.
Tuned threshold. A fixed dosimetric threshold grid-searched to maximize net monetary benefit, using the same economic model and the same leave-one-patient-out folds.
Ablations. Our model without the setup-noise term, which isolates the two-phase correction, and our model without pooling, fit per patient.
Fairness rules apply to all baselines. Every policy sees the same daily dose estimates. Every policy is scored by the same Markov model, costs, and adherence assumption. Tuned policies get the same tuning folds. "Beating" a baseline means a paired leave-one-out gain in net monetary benefit whose bootstrap interval excludes zero, or, failing that given N, a lower false-trigger rate in sessions 1–6 with equal or better end-of-treatment parotid dose.
Why not just…?
Why not just run a standard Markov cost-effectiveness analysis of adaptive versus non-adaptive radiotherapy? That answers whether adaptation is worth it on average. It does not answer when to trigger it, which is the decision the software now enables. We build that model anyway as the scoring engine. The contribution is the policy search and the value-of-information layer on top of it.
Why not just grid-search the dosimetric threshold against net monetary benefit? This is the real threat. With 27 patients, a one-parameter rule may match a richer model, because the extra flexibility has little data to learn from. We include it as a first-class baseline. If it ties our method, we will report that the gains come from the economic objective rather than the forecaster. In that case the recommendation becomes "keep simple thresholds, set them by cost." The one place we expect the richer model to win is early setup-driven false alarms, where a threshold cannot distinguish transient from persistent deviation. The session 1–6 ablation tests this specifically.
Why not just use a stronger nonlinear forecaster, such as boosted trees or a recurrent network? At N ≈ 27, with wide intervals already reported by the RTapp study, such models will overfit and produce overconfident forecasts. Overconfidence is directly costly in a decision rule. We include a gradient-boosted forecaster under the same decision rule and compare calibration (interval coverage) and net monetary benefit.
Proposed Experiments
Data. The primary data is a retrospective daily-CBCT head and neck cohort matching the Loyola design: VMAT patients (volumetric-arc radiotherapy) with full-field CBCT and deformed dose. We augment it with patients who were actually replanned and rescanned, as in the 12-patient stepwise HU set. The rescanned patients provide real counterfactual "replanned" dose, rather than an assumption that replanning restores the planned dose. HNTS-MRG 2024 supplies the external drift prior. We will check that the prior's implied volume change agrees with the local cohort; disagreement is itself a transfer result.
Replay evaluation. We replay every policy session by session under leave-one-patient-out. The outputs are net monetary benefit per patient, number of replans, false triggers in sessions 1–6, end-of-treatment parotid dose excess, PTV coverage loss, and ICER versus no adaptation. Probabilistic sensitivity analysis covers the complication-model, utility, and cost parameters. Those values come from published sources outside this file and are all varied widely. Following Chan et al., we specifically report whether the policy ranking flips within plausible cost ranges.
Decisive checks. Three results decide the project. First, whether the pooled cost-aware rule beats the net-monetary-benefit-tuned threshold on paired net benefit. If not, the simpler rule is the answer. Second, whether forecast 80% intervals cover about 80% of held-out outcomes, with the linear baseline as the comparison. Third, whether the value of sample information at plausible thresholds exceeds the cost of a multicenter study of a stated size. If it does, the small-sample limitation becomes a funded, quantified next step rather than a caveat.
References
- Cost-effectiveness of sofosbuvir-based treatments for chronic hepatitis C in the US
- Retrospective Clinical Evaluation of a Decision-Support Software for Adaptive Radiotherapy of Head and Neck Cancer Patients
- Feasibility of <scp>CBCT</scp>‐based dose with a patient‐specific stepwise <scp>HU</scp>‐to‐density curve to determine time of replanning
- The value for money of artificial intelligence-empowered precision medicine: a systematic review and regression analysis
- Deep Learning for Longitudinal Gross Tumor Volume Segmentation in MRI-Guided Adaptive Radiotherapy for Head and Neck Cancer
- Comparative Analysis of nnUNet and MedNeXt for Head and Neck Tumor Segmentation in MRI-Guided Radiotherapy
- Parotid gland radiation dose‐xerostomia relationships based on actual delivered dose for nasopharyngeal carcinoma
- OpenMarkov, an Open-Source Tool for Probabilistic Graphical Models
- To do or not to do: cost-sensitive causal decision-making
- Entropy removal of medical diagnostics
- Cost-Effectiveness of Transcatheter Aortic Valve Implantation in Intermediate and Low Risk Severe Aortic Stenosis Patients in Singapore