When radiologists outline an organ in a CT or MRI scan, they draw one axial slice at a time. Their mistakes follow that habit. A mask may be slightly too wide on one slice and slightly too narrow on the next, or it may be interpolated between the few slices that were drawn by hand. Viewed in the drawing plane, each wrong outline still looks like a plausible organ. Viewed from the side, in a coronal or sagittal slice, the same errors show up as a ragged staircase along the depth axis. We propose to use this asymmetry as a label-noise detector.
The method trains three cheap 2D segmentation networks, one for each orthogonal viewing plane, on the same noisy 3D masks. Label voxels that the side-view networks consistently refuse to fit, while the axial network accepts them, are treated as suspect. Each network is then retrained on labels cleaned by the other two. The result is a disagreement-based noise filter that uses 3D context at 2D memory cost. Its diversity comes from the geometry of how labels are made, not from pairing different architectures.
Core Claim
Noise that is smooth within the annotation plane is rough across it. A 2D network whose image plane contains the depth axis should therefore memorize slice-drawn label errors more slowly than a network looking along the drawing plane. This is a specific form of the observation that networks fit clean, regular structure before idiosyncratic exceptions. If the prediction holds, disagreement between orthogonal-plane networks is a sharper noise signal for real volumetric annotation errors than two identical or architecturally different networks that share the same slicing.
This is also where two existing lines of work fall short. Slice-wise disagreement filters struggle here: two axial networks see the same smooth in-plane error on each slice, so they tend to agree and the filter goes silent. A single 3D network sees the whole volume, but it has enough capacity to memorize the error as a 3D shape. The claim has a clear boundary. For label errors that are smooth in 3D, such as a dilation applied consistently across many slices, the advantage should vanish and the method should reduce to ordinary disagreement filtering. We will test that boundary directly.
Positioning Against Prior Work
The mechanism combines two ideas that have so far been used for different purposes.
Multi-planar co-training in DMPCT trains axial, coronal and sagittal 2D networks and fuses their votes into pseudo-labels for unlabeled CT. It assumes the labeled set is clean and uses cross-plane agreement only to add labels, never to question them. We reuse its three-plane architecture, but point its disagreement at the given labels.
Disagreement-based noise filtering supplies the training rule. Update-by-disagreement from Malach et al. and Co-teaching+ restricts learning to contested samples. JoCoR instead pushes networks toward agreement. The closest segmentation analogue is Diverse Learning Groups. It pairs a ResNet-50 with a Pyramid Vision Transformer, scores each pixel by prediction-label cross-entropy and inter-model divergence, and lets each group train on pixels cleaned by the other. It was evaluated on SegTHOR thoracic CT, but slice by slice. We keep its cross-cleaning structure and replace architectural diversity with orientation diversity.
Two 2D medical methods constrain the design. CLCS shows that disagreement filtering needs class-dependent thresholds so that rare structures survive, and that flagged pixels are better kept under a reverse cross-entropy loss than discarded. NA-CLD shows the failure without such care: after filtering, background occupied nearly 99% of training pixels. Both were built on 2D images, and CLCS explicitly names 3D CT and MRI as future work. We adopt their imbalance and retention fixes as components rather than contributions.
ALC is the strongest existing 3D noisy-label method. It uses a mean teacher (a copy of the model with slowly averaged weights) to estimate uncertainty from input perturbations, then selects whole volumes. It differs from our proposal in three ways: it relies on a single model's perturbation consistency, it makes decisions per scan rather than per voxel, and it needs a verified high-quality subset.
DGRNet computes voxelwise disagreement across adapter branches in 3D MRI. However, it uses that disagreement to refine predictions on clean data, not to filter labels. Finally, Roth et al. motivate the problem. Their 2D pancreas predictions rose from 56% to 68% Dice after 3D Gaussian smoothing, which shows that inter-slice inconsistency is large and that depth-axis structure carries real signal.
Research Program
The system has three 2D segmentation networks with identical backbones: nnU-Net's 2D configuration from The Medical Segmentation Decathlon. Each is trained on the volume resliced along one plane, with the noisy mask resliced to match. Predictions from all three are projected back into voxel space every few epochs. Thick-slice anisotropy makes the side views coarse along depth. We keep them at native spacing rather than resampling, because the coarse depth axis is exactly where slice-drawn errors look ragged.
For each voxel $v$ and view $k$, let $d_k(v)$ be the cross-entropy between view $k$'s prediction and the given label. The noisiness score for the axial network's training signal is computed from the other two views:
$$s_{\text{ax}}(v) = \tfrac{1}{2}\big(d_{\text{cor}}(v) + d_{\text{sag}}(v)\big),$$
The scores for the coronal and sagittal networks are defined symmetrically. A voxel is flagged for network $k$ when its score exceeds a class-dependent threshold $\tau_c(t)$. Here $c$ is the given label's class and $t$ the epoch. Following CLCS, the threshold starts permissive during warm-up and tightens over time, with lower thresholds for minority classes. Flagged voxels are not dropped, since dropping them would punch holes in 3D surfaces. They move from ordinary cross-entropy to reverse cross-entropy. The final prediction is the three-view fusion, optionally distilled into a single 3D network to remove the ensemble cost at inference.
The program has three parts. The first is a mechanism study. Before any filtering, we record per epoch the fraction of corrupted voxels that each view network has memorized, under a known noise model. The second is the full method. The third is a regime map showing where orientation diversity helps and where it does not.
Three synthetic noise families are applied to clean masks:
- Axial-drawn noise: independent per-slice dilation or erosion of 3–15 pixels, following ALC's protocol but applied slice by slice.
- Sparse annotation with interpolation: every k-th slice is kept and the slices in between are linearly interpolated.
- Isotropic 3D control: dilation or erosion applied in 3D.
These families run on NIH Pancreas, the pancreas, liver and spleen tasks of the Decathlon, SegTHOR, and Left Atrium MRI. Where the real-noise gastric CT set used by ALC is obtainable, we will report on it too. The file contains no public multi-rater 3D benchmark, so real-noise evidence may be limited to that dataset.
Baselines
The naive reference is nnU-Net 3D full-resolution trained directly on the noisy masks with its default augmentation. It is the configuration that dominated the Decathlon. That paper reports 0.94 Dice on spleen and liver but only 0.21 on pancreas tumors with clean labels, so it sets the floor for how much noise hurts a strong 3D pipeline. We run it with the same folds and the same number of GPU-hours as our method. We also run the same three plane networks trained on noisy labels with DMPCT-style majority-vote fusion and no filtering. This isolates whether the gain comes from filtering or merely from tri-planar ensembling.
The strongest existing 3D method is ALC. On NIH Pancreas, with 10% high-quality and 90% boundary-corrupted labels, it reports 75.21% Dice, 5.86 mm 95th-percentile Hausdorff distance and 2.02 mm average surface distance. We reproduce that exact split and noise protocol, and give our method the same 10% clean subset only as an optional warm-up. We also run both methods with zero clean labels, which is the setting ALC's design does not cover. Beating ALC means exceeding 75.21% Dice and reducing 95th-percentile Hausdorff distance in its own setting, while degrading less in the fully noisy one.
The strongest disagreement baseline is Diverse Learning Groups. On SegTHOR it reports 73.5% mIoU against 70.8% for ADELE. We rerun it slice-wise with the authors' noise protocol and with ours, at matched parameter count and epochs. Beating it means higher mIoU and higher voxel-level noise-detection precision on SegTHOR under axial-drawn noise.
The key ablation replaces the three orientations with three axial networks that differ in random seed, or in backbone (CNN versus transformer). Compute and all other components stay the same. If orientation is the active ingredient, orthogonal views should give clearly higher noise-detection precision and recall than same-plane diversity.
Why not just…?
Why not just smooth the noisy labels along the depth axis before training? For purely per-slice independent jitter, a depth-axis median or Gaussian filter on the masks could remove much of the noise with no learning at all. We treat this as a real threat. It is included as a baseline: the smoothed masks are fed to nnU-Net 3D. The expected difference appears with sparse-annotation interpolation and with jitter that is locally correlated across a few slices. There, blind smoothing either leaves the error or erodes thin structures, much as Roth et al.'s Gaussian smoothing helped overall but left 68% ± 10% Dice with failures at low-contrast boundaries. If depth smoothing matches our method across all noise families, the learned filter is not justified, and we will say so.
Why not just run co-teaching with two 3D networks? This is the most direct transfer of disagreement filtering to volumes. Two identical 3D networks see the same data and can memorize the same 3D-shaped error, which is the consensus-collapse problem that Co-teaching+ and Diverse Learning Groups add diversity to avoid. They also double 3D memory. We run Co-teaching+ with two 3D nnU-Nets at matched GPU-hours, shrinking patch size as needed. Our claim fails if this baseline matches our noise-detection precision under axial-drawn noise.
Why not just use a single mean-teacher model with perturbation consistency? ALC does this and is strong. However, its own ablation found that its whole-volume selection matters more than its label refinement, which suggests that voxel-level perturbation uncertainty alone is weak. A single model's perturbations also share its inductive bias. The ALC comparison above settles the question. If ALC wins when a clean subset exists but loses without one, that is the honest scope of our contribution.
Decisive Checks
The first check tests the mechanism and could kill the idea on its own. Under axial-drawn noise, the coronal and sagittal networks must memorize corrupted voxels measurably later than the axial network, while memorizing clean voxels at a similar rate. If the memorization curves coincide, the approach reduces to generic ensembling and we stop.
The second check is the orientation ablation. Orthogonal views must beat same-plane seed or backbone diversity in noise-detection precision, not merely in final Dice.
The third check is the regime map. The advantage should be large for axial-drawn and interpolated noise, and should shrink toward zero for isotropic 3D dilation. A method that wins equally on all three families would suggest the gain comes from something other than the stated mechanism.
Across all of these we report Dice, 95th-percentile Hausdorff distance and average surface distance. We also report per-class recall on small structures such as the pancreas and esophagus, to confirm that class-aware thresholds prevent the imbalance collapse, and peak training memory, to support the claim of 3D context at 2D cost.
References
- Semi-supervised multi-organ segmentation via multi-planar co-training
- Decoupling "when to update" from "how to update"
- How does Disagreement Help Generalization against Label Corruption?
- Combating Noisy Labels by Agreement: A Joint Training Method with Co-Regularization
- Semi-Supervised Semantic Segmentation under Label Noise via Diverse Learning Groups
- Imbalanced Medical Image Segmentation With Pixel-Dependent Noisy Labels
- Clean Label Disentangling for Medical Image Segmentation with Noisy Labels
- Adaptive Label Correction for Robust Medical Image Segmentation with Noisy Labels
- DGRNet: Disagreement-Guided Refinement for Uncertainty-Aware Brain Tumor Segmentation
- Deep convolutional networks for pancreas segmentation in CT imaging
- The Medical Segmentation Decathlon