Measure the Slice Before You Sharpen It: Per-Scan Slice-Profile Identification for Cross-Center Volumetric Super-Resolution

Most hospital CT and MRI scans are acquired as thick slices, typically 3 to 8 mm apart, with much finer detail within each slice. Super-resolution networks, which learn to fill in the missing thin slices, are trained on pairs made by blurring and subsampling thin scans with an assumed recipe. A real scanner does not follow that recipe. Each scanner and protocol mixes neighbouring tissue into a slice with its own weighting curve, called the slice sensitivity profile, and places slices at its own offsets. When a network meets a center whose profile differs from its training recipe, it reconstructs the wrong inverse problem.

This note proposes that a small set of physical numbers per scan is the main lever for cross-center generalization: profile width, profile shape, and slice offset. These can be estimated from the thick scan itself, without any paired thin acquisition. A single continuous-coordinate network told those numbers should transfer to new centers, including centers with only a handful of scans, better than larger architectures or whole-network test-time adaptation. We would judge success on downstream clinical measurements as well as pixel scores.

Core Claim

The evidence that the degradation model matters more than the architecture is already in the literature, but nobody has made it adaptive per scan. Enhancing Super-Resolution Networks through Realistic Thick-Slice CT Simulation builds training pairs with a triangular slice weighting derived from the scanner's reconstruction algorithm plus DICOM-correct slice placement. Its simulated slices match real thick slices at 49.74 dB PSNR, compared with 40.66 dB for simple averaging. The same 3D ESRGAN gains about 1.1 dB on real pairs (37.98 vs 36.84 dB), and only the realistically trained model yields radiomic features that predict mortality in lung fibrosis. That paper fixes one kernel for one scanner family. Methods that do adapt to new data assume the degradation instead of measuring it. DA-VSR fine-tunes its backbone on each target scan using downsampled in-plane slices, which presumes that in-plane blur imitates through-plane slice integration. CycleINR enforces that re-degrading its output reproduces the input, but only through a known, fixed downsampling operator. InverseSR likewise needs the corruption function to be specified.

Our claim is that a profile-conditioned, arbitrary-scale volumetric network plus a per-scan profile estimator will match or beat these methods on unseen centers. The estimator is cheap and label-free, and the network itself is never updated at test time. Only three or four profile numbers are fitted per scan, which makes the method safe when a target center contributes five scans rather than five hundred. The claim is falsifiable in a specific way. If a network trained blind on a randomized family of realistic profiles, never told the profile, performs as well as the conditioned one, then explicit identification is unnecessary and we will say so.

Research Program

Forward model. We model each acquired thick slice $k$ as a weighted integral of the underlying thin-slice signal along the through-plane axis:

$$y_k(u,v) = \int s_\theta(z - k\Delta - \delta)\, x(u,v,z)\, dz + n_k(u,v).$$

Here $x$ is the high-resolution volume, $(u,v)$ are in-plane coordinates, and $\Delta$ is the slice spacing read from DICOM. The profile $s_\theta$ comes from a family indexed by $\theta = (w, \alpha, \delta)$. The width $w$ is the effective thickness. The shape parameter $\alpha$ moves continuously from box to triangle to Gaussian, which covers both the averaging and wFBP-style kernels studied in the thick-slice simulation paper. The offset $\delta$ is the slice centering. The term $n_k$ is noise. Nominal thickness in the DICOM header seeds $w$, but the effective value and shape are unknown.

Per-scan profile estimation. We exploit the fact that the same anatomy is seen at high resolution within each slice. Blurring an in-plane axis with the true profile should make its local one-dimensional power spectrum statistically match the through-plane spectrum. We estimate

$$\hat\theta = \arg\min_\theta \; D\big(P_z[y],\; P_u[s_\theta * x_{\text{in-plane}}]\big),$$

where $P_z$ and $P_u$ are local power spectra along the through-plane and an in-plane axis, $s_\theta *$ denotes blurring with the candidate profile, and $D$ is a log-spectral distance. To make the fit robust to genuine anatomical anisotropy, we learn a small regressor that predicts $\theta$ from paired spectra. It is trained on thin volumes degraded with randomly drawn profiles, and the analytic fit initializes and sanity-checks its output.

We do not claim spectral blind kernel estimation is new in itself. The contribution is closing the loop between the estimator, the reconstruction network, and the cycle-consistency used at inference, and then testing whether this closed loop is what drives multi-center transfer.

Reconstruction network. The network continues the line of continuous-coordinate decoders, which predict intensity at any 3D query point and so handle any non-integer spacing, as in SA-INR and CycleINR. Those decoders use mostly local 2D features. SuperFormer shows that native 3D windowed self-attention beats slice-wise SwinIR, but it is tied to a fixed voxel grid and constrained by memory.

We use a modest 3D windowed-attention encoder on sub-volumes to keep out-of-plane context. Each query to the coordinate decoder receives local features, its coordinate relative to neighbouring acquired slices, and $\hat\theta$. Training uses $L_1$ loss on thin volumes degraded by profiles sampled across the realistic family. We add a cycle term that re-degrades the prediction through $s_{\hat\theta}$, CycleINR's idea with an estimated operator instead of an assumed one. We deliberately avoid adversarial and diffusion losses. Their sharpness is bought with the hallucination risk noted for generative priors, and our endpoints are quantitative clinical measurements.

Multi-center, small-sample protocol. All transfer experiments are leave-center-out, and no target-center thin data is used for training or tuning. To probe the small-sample regime, each target center is evaluated with only 5, 10, or all of its scans available to methods that adapt. Our method uses none of them for weight updates. Per-scan profile estimates are reported per center, so that if, say, LDCT-GC's effective thickness ends up wider than its nominal value, we can see which scanners drive any failures.

Baselines

Naive reference. Cubic interpolation along the through-plane axis is the do-nothing reference. It needs no data and cannot hallucinate. On IXI at 4 mm, InverseSR reports SSIM 0.760 for cubic interpolation. We rerun it on every split.

Strongest supervised competitor on real thick/thin pairs. This is the 3D ESRGAN trained with realistic thick-slice simulation from Enhancing Super-Resolution Networks through Realistic Thick-Slice CT Simulation, which reports 37.98 dB PSNR on the Low Dose CT Grand Challenge (LDCT-GC). LDCT-GC is the only dataset in the file with real scanner-produced thick/thin pairs. This baseline already encodes the physics we build on, but with one fixed kernel. Beating it means a PSNR gain on LDCT-GC real pairs that is statistically reliable across patients and accompanied by lower error on downstream measurements. We additionally retrain this baseline with a 3D windowed-attention backbone matching ours, so the comparison does not reward architecture.

Strongest adaptive competitor. DA-VSR adapts its whole backbone per target scan using in-plane self-supervision. It reports 38.07 dB at 4× on KiTS19 after training on LIDC-IDRI, against 37.60 dB without adaptation and 37.70 dB for SAINT. We reproduce its LIDC-IDRI to KiTS19 protocol and require our method to at least match 38.07 dB there without updating any weights. On non-integer spacings, where DA-VSR's fixed heads need resampling, we expect to beat it outright. Because DA-VSR is fixed at integer scales, we run it at the nearest integer factor followed by interpolation, and report that choice.

Generative competitor. We use InverseSR on IXI: 0.803 SSIM and 29.64 dB PSNR at 4 mm for its decoder variant, 0.754 SSIM at 8 mm for its LDM variant. It is the strongest zero-shot cross-cohort result in the file. Beating it means higher SSIM at both thicknesses at a fraction of its iterative inference time, with a separate lesion-preservation check on BraTS2020.

Ablations. - Oracle profile: the true $\theta$ is fitted from paired data where available. This bounds what estimation can achieve. - Blind randomized: the same network and training profile distribution, but with no $\theta$ input. - Fixed-kernel: the same network trained on the triangular kernel only. - Estimator plugged into a DA-VSR-style scheme: our $\hat\theta$ replaces DA-VSR's assumed in-plane blur, separating "better operator" from "conditioning versus adaptation."

All learned methods get the same training volumes, the same GPU-hour budget, and the same number of hyperparameter trials on a source-center validation split.

Why not just…?

Why not just train one blind network on a randomized family of realistic slice profiles? This is the most serious alternative, because domain randomization often works. The thick-slice simulation paper shows that the kernel family matters, but not that per-scan knowledge of the kernel matters. Our blind-randomized ablation is exactly this alternative. We expect it to suffer where width and anatomy trade off: a blurry edge could be thick slices or genuinely smooth tissue, and averaging over that ambiguity produces regression-to-the-mean blur. If the conditioned model's advantage over blind randomization falls within patient-level variance on LDCT-GC and the leave-center-out splits, we will report that profile identification is unnecessary. The deliverable would then become the randomized training recipe.

Why not just use DA-VSR-style test-time adaptation? It updates a full backbone from one scan's in-plane slices. The thick-slice simulation results suggest the in-plane surrogate misrepresents through-plane integration. Fitting millions of weights to one scan also invites overfitting exactly in the small-cohort regime. The ablation that feeds our $\hat\theta$ into DA-VSR's adaptation will show whether its gap comes from the wrong operator, which estimation fixes, or from adapting at all. If DA-VSR with $\hat\theta$ beats our frozen conditioned network, we adopt adaptation and say so.

Why not just invert a generative prior, as InverseSR does? It transfers zero-shot from UK BioBank to IXI. However, it needs a specified corruption operator and hundreds of optimization steps per volume. Its prior is learned from healthy brains, so it may pull lesions toward normal anatomy. Our profile estimate could supply its missing operator. We run InverseSR with both its default operator and with $s_{\hat\theta}$, which tests the estimator's value independently of our network. We then compare lesion-region error on BraTS2020 against our non-generative reconstruction.

Why not just harmonize scanners first, as with an information bottleneck? The Overview of Scanner Invariant Representations method removes scanner identity from features: adversary accuracy falls to 0.41 from 0.85 without the bottleneck. But it does not perform through-plane super-resolution, and stripping site information risks removing the fine edges that downstream tools depend on. We treat it as complementary rather than competing. A post-hoc site classifier on our encoder features will report how much scanner identity survives once the profile is explicitly supplied.

Decisive Experiments

The first check is whether the profile can be measured at all. On LDCT-GC we fit the true effective profile from real thick/thin pairs and compare it with the label-free estimate from the thick scan alone. Estimation error in width and offset must be small relative to slice spacing, or the rest of the program is moot.

The second check is the central ablation. Oracle, estimated, blind-randomized, and fixed-kernel conditioning are compared under leave-center-out evaluation. The splits are LDCT-GC real pairs; LIDC-IDRI to KiTS19 and to Medical Segmentation Decathlon (MSD) Liver for cross-organ CT; and IXI, which the file describes as multi-center, for MRI at 4 and 8 mm. Each is evaluated at integer and non-integer spacings. Metrics are PSNR and SSIM, plus CycleINR's slice-wise noise inconsistency score, for which CycleINR reports 0.3527 against SAINT's 1.6724 at 2×.

A misspecification sweep complements this. We train with box profiles and test with triangular ones, and the reverse. This directly measures how much fixed-kernel methods lose, and how much estimation recovers.

The third check concerns downstream endpoints, which the thick-slice simulation paper showed can diverge from PSNR. These include liver tumor Dice on MSD Liver. Where the Australian IPF Repository is accessible, we test whether radiomic features from reconstructed scans keep the mortality association reported there, with hazard ratios of 1.19 and 1.14. We also compare nodule detection on reconstructed versus native thick scans, following the design of Deep Learning-Based Slice Thickness Reduction for Computer-Aided Detection of Lung Nodules in Thick-Slice CT, which improved scan-level AUC from 0.867 to 0.902 at a single center. Our version runs that comparison across centers, with 5, 10, or all target scans.

The proposal succeeds if two things hold. The estimated profile must recover most of the oracle's margin over blind randomization. That margin must also persist in these downstream measures at unseen centers.