Most large vision-language models read a CT scan as a pile of disconnected 2D pictures. They were trained on flat images, so a 3D volume is cut into slices or patches before the model sees it. This loses what radiologists rely on: how an organ, vessel, or lesion continues from one slice to the next and across planes. We call this volumetric context loss. We propose to keep a capable 2D reader frozen and train a small, separate agent whose only job is to decide what the reader should look at. Each "view" is a choice of viewing plane (axial, coronal, or sagittal), a position, and a slab thickness, under a fixed budget of views. The agent is trained by reinforcement learning (trial and error against a reward). The reward is how much each view raises the frozen reader's confidence in the correct answer.
Keeping the two parts apart buys something a single end-to-end system cannot give: when the system answers wrongly, we can tell whether it looked in the wrong place or misread a view it was shown. Because the agent can request reformatted planes and thick slabs, it can put out-of-plane structure back in front of a model that only understands flat images. The claim to test is specific. Learned view selection should beat both uniform slice sampling and segmentation-guided heuristic selection. The gain should concentrate on questions whose evidence is relational or out-of-plane, and the navigator should transfer to a different frozen reader without retraining.
Core Claim
The closest prior systems split along two lines. 3DMedAgent already separates perception from reasoning. A frozen 2D multimodal model drives segmentation tools, attention heatmaps, and a one-slice-at-a-time loop that writes text notes to memory. It reaches 66% average accuracy on DeepTumorVQA against 37% for RadFM and 39% for M3D. Its slice choices, however, come from prompts and fixed heuristics, never from a learned policy, and its notes turn geometry into text. Med3D-R1 does use reinforcement learning, specifically group relative policy optimization (GRPO), which scores a group of sampled outputs against each other instead of training a separate value network. It applies this to a single monolithic model reading a downsampled volume, so it cannot separate seeing errors from reasoning errors. Deep Reinforcement Learning for Organ Localization in CT shows that an agent can search native 3D CT efficiently, reaching 0.63 mean IoU on VISCERAL from 70 scans. That agent is a single network with fixed step sizes and a box-overlap reward, and it reaches only 0.32 IoU on the pancreas.
Our proposal differs from all three. The navigation policy is trained and the reader is frozen. The reward comes from the reader's answer rather than from geometric overlap. The actions include plane and slab choices that restore depth context. This continues the modular reinforcement learning tradition in which an interchangeable component sits behind a fixed interface. Oliveira et al. isolate model, planner, policy, and loss, and Composable Modular Reinforcement Learning shows that arbitration stays stable whatever the internals of each module. Here the frozen reader plays the role of a fixed environment module.
Research Program
The reader. The reader is an off-the-shelf 2D multimodal model, held fixed throughout. It receives the question and the rendered views so far. For multiple-choice questions it returns a probability over the answer options.
The navigator. The navigator is a small policy network, a few million parameters. It sees two inputs: a coarse, heavily downsampled copy of the whole volume, which is cheap to process, and an embedding of the views already chosen. Each action selects a plane orientation, a continuous position along that plane's normal, an in-plane crop scale, and a slab thickness. A thin slab is a single slice. A thick slab is rendered as a maximum-intensity projection or as adjacent slices stacked into color channels. The action space is continuous, which avoids the fixed-step oscillation that hurt Navarro et al. on small organs. An episode lasts $K$ views, with $K$ between 4 and 12. This budget is matched across all methods.
The reward. Let $p_R(a^\star \mid v_{1:t}, q)$ be the frozen reader's probability of the correct answer $a^\star$, given question $q$ and the first $t$ views. The per-step reward is
$$r_t = \log p_R(a^\star \mid v_{1:t}, q) - \log p_R(a^\star \mid v_{1:t-1}, q),$$
and a terminal reward of 1 is added if the reader's final top answer is correct. The step rewards add up to the final log-probability minus a constant that depends only on the question. The shaping is therefore dense but does not change which policies are best. It is the answer-space analogue of Navarro et al.'s relative IoU reward. We optimize with GRPO over groups of navigation trajectories per question, as Med3D-R1 does. Gradients flow only into the navigator, so the reader is called but never backpropagated through.
Error decomposition. This is the analysis that monolithic systems cannot do. Several benchmarks either come with masks or can be paired with masks from AMOS, BTCV, or TotalSegmentator-style labels. For those questions we check whether each failed episode's views actually contained the evidence structure. We then replay the reader on oracle views rendered from the mask. This splits every error into one of two kinds: the system did not look at the evidence, or it looked and misread it.
Baselines
Uniform slices (naive reference). The same frozen reader receives $K$ evenly spaced axial slices; a central-slice variant is also included. This is the do-nothing point. No reported number on Lacuna is found for it on DeepTumorVQA. The MIRP results suggest 2D-slice readers sit near chance (about 50%) on spatial relations.
Segmentation-guided heuristic selection. This is the most dangerous competitor on this exact question. It is our reimplementation of 3DMedAgent's slice selection: run organ segmentation, then take the $K$ axial slices with the largest mask area for the organs named in the question, refined by a text-image heatmap. It uses the same reader and the same $K$. Its tool costs are counted in the compute budget.
3DMedAgent as published. We compare against its reported 66% on DeepTumorVQA. We also run its full pipeline where it can be reproduced, so that differences caused by reader choice are separated from differences caused by selection.
Monolithic end-to-end training. This is a Med3D-R1-style setup. The reader itself is fine-tuned with GRPO on uniform slices, under the same GPU-hour budget and the same hyperparameter search budget as our navigator. On CT-RATE the published reference is Med3D-R1's 41.92% multiple-choice accuracy, and 44.99% on RAD-ChestCT.
Ablations isolating the key ingredients. We run four. An axial-only navigator tests whether reformatted planes and slabs matter. A navigator trained with only the terminal reward tests the value of dense shaping. A navigator trained to maximize mask coverage, with no reader feedback, tests whether answer-driven reward matters beyond "find the organ." A navigator trained on reader A and evaluated with reader B tests whether the module boundary is real.
What counts as beating a baseline. The navigator must exceed the segmentation-guided heuristic at equal $K$ and equal compute. The gain must hold across at least three seeds. It should appear in particular on the relational and out-of-plane question subsets. It should also cut the error share attributed to navigation, without increasing the share attributed to reading.
Why not just…?
Why not just pick slices with a segmentation tool? This is a real threat. For questions about one named organ's size or density, picking the largest-mask slices is probably close to optimal, and we expect no gain there. The case for learning rests on two kinds of questions where a mask does not say which views carry the evidence. The first is relational: which structure is more cranial, or whether a lesion abuts a vessel. The second is lesion-centric, where the target is not a pre-segmented organ. The coverage-reward ablation and per-category reporting settle this directly. If the learned policy only matches the heuristic on those categories, we will report that the heuristic suffices.
Why not just feed the reader many more slices? Long contexts of independent slices still present depth as an unordered stack of flat images. MMGPL reports that flat sequences of 2D patches fail to capture inter-slice relationships. We test this directly by sweeping uniform $K$ up to the reader's context limit. If accuracy rises with $K$ until it matches the navigator, the case for a navigator reduces to inference cost alone.
Why not just fine-tune the reader end-to-end with GRPO? This is the Med3D-R1 route, and it is included as a compute-matched baseline. Even if it matches on accuracy, it gives up three things: the ability to swap readers, the frozen reader's general abilities, and the navigation-versus-reading error split. Its view distribution is fixed to uniform slices, so it also cannot recover out-of-plane structure that those slices never show.
Why not just use a native 3D network? On segmentation, the AMOS benchmark shows a plain 3D-UNet reaching 89.04% mDice on CT. Such networks do not answer questions, however. AMOS also reports drops of more than 20% on unseen MRI scanners. We use 3D segmentation only as the tool behind the heuristic baseline, not as a competitor for question answering.
Proposed Experiments
Primary benchmarks. We use DeepTumorVQA and DeepChestVQA for the comparison with 3DMedAgent, and CT-RATE and RAD-ChestCT multiple-choice VQA for the comparison with Med3D-R1. Metrics are accuracy per question category and overall.
Volumetric relational probe. We build a 3D extension of MIRP from AMOS and BTCV volumes. Its questions are answerable only across slices or planes: cranio-caudal order, cross-slice continuity, and coronal adjacency. The answer is defined from the masks, so chance and the uniform-slice baseline are well-defined reference points.
First decisive check. On the relational probe and the lesion subset of DeepTumorVQA, the navigator should beat the segmentation-guided heuristic at equal $K$. On single-organ attribute questions it should roughly tie. A uniform gain across all categories would suggest the navigator is exploiting reader quirks rather than restoring context. We would examine that with the oracle-view replay.
Second decisive check. The axial-only ablation should lose most of the gain on out-of-plane questions. If it does not, plane and slab choice is not where volumetric context is being recovered.
Third decisive check. A navigator trained against one reader should keep most of its advantage over the heuristic when paired with a second reader it never trained with. Transfer is what justifies the modular design over Med3D-R1-style joint training.
Error decomposition report. For every method we report the fraction of failures in which the evidence was never shown versus shown but misread. If the navigator drives navigation failures near zero while overall accuracy stays capped, the bottleneck has moved to the 2D reader, consistent with the textbook-bias findings in Your other Left!. The decomposition would make that limit visible rather than hide it.
References
- 3DMedAgent: Unified Perception-to-Understanding for 3D Medical Analysis
- Med3D-R1: Incentivizing Clinical Reasoning in 3D Medical Vision-Language Models for Abnormality Diagnosis
- Deep Reinforcement Learning for Organ Localization in CT
- Assessing Policy, Loss and Planning Combinations in Reinforcement Learning Using a New Modular Architecture
- Composable Modular Reinforcement Learning
- Your other Left! Vision-Language Models Fail to Identify Relative Positions in Medical Images
- MMGPL: Multimodal Medical Data Analysis with Graph Prompt Learning
- AMOS: A Large-Scale Abdominal Multi-Organ Benchmark for Versatile Medical Image Segmentation