How Much of Expert Disagreement Is Just Blur?

When several radiologists outline the same structure on a CT or MRI scan, their outlines disagree, and current methods treat all of that disagreement as human judgment to be modeled. Much of it, however, may come from physics. A scanner records each voxel (a small 3D pixel) as the average of whatever tissues fall inside it. This partial volume effect turns a sharp anatomical edge into a gradient a few voxels wide, and any reasonable rater must place the line somewhere inside that gradient. This proposal builds a model that splits boundary disagreement into two parts. The first is a physics part, predicted from the scanner's voxel geometry and blur alone, with no labels needed. The second is a residual judgment part, and that part is where clinical context, such as a patient's lab values, should matter. Splitting disagreement this way makes uncertainty transfer across scan resolutions, which current multi-rater models cannot do. It also tells us which imaging measurements to trust when we correlate them with symptom scores.

The test that makes this falsifiable is cheap. Clinical scans are usually anisotropic: slices are thick (say 5 mm) while in-plane pixels are fine (say 0.7 mm). If disagreement is mostly partial volume, the band of disagreement should be wide where the boundary runs across slices and narrow where it runs within a slice, scaling with the voxel dimension along the boundary's normal. Human judgment has no reason to follow that geometry. Measuring this orientation dependence on existing multi-rater data, and then building a model around it, is the core of the work.

Core Claim

We claim that a predictable, resolution-dependent fraction of inter-rater boundary disagreement in tomographic images is explained by a forward model. In that model, a sharp latent boundary is blurred by the scan's anisotropic point-spread function (the blur pattern the scanner applies to a single point). Modeling disagreement as this physical blur plus a learned residual gives three things. It matches multi-rater label distributions as well as ensembles do, at single-network cost. It extrapolates those distributions to slice thicknesses never seen in training. Its sharp latent boundary yields volume and thickness measurements whose correlation with clinical scores degrades less as resolution worsens.

For a boundary with unit normal $n$ in a scan with per-axis effective blur widths $s_x, s_y, s_z$ (voxel size combined with point-spread width), the physics part predicts a disagreement band of width

$$w_{\text{phys}}(n) = \sqrt{(n_x s_x)^2 + (n_y s_y)^2 + (n_z s_z)^2},$$

which follows from projecting an anisotropic Gaussian blur onto the boundary normal. The model then predicts the probability that a rater labels a voxel as foreground as

$$p(v) = \Phi\!\left(\frac{d(v)}{\sqrt{w_{\text{phys}}(n_v)^2 + \sigma_{\text{judg}}(v,c)^2}}\right).$$

Here $d(v)$ is the signed distance from voxel $v$ to the latent sharp boundary, $n_v$ is the boundary normal nearest $v$, $\Phi$ is the standard normal cumulative distribution, and $\sigma_{\text{judg}}(v,c)$ is a learned judgment spread that may depend on clinical context $c$. The physics term is fixed by the scan header and a measured or assumed point-spread width, and has no free parameters per image. Everything the network learns about disagreement beyond blur must go into $\sigma_{\text{judg}}$.

How This Relates to Prior Work

The motivating evidence comes from Exploring Uncertainty Measures in Bayesian Deep Attentive Neural Networks for Prostate Zonal Segmentation, which observed with Monte Carlo dropout that uncertainty peaks at prostate zone junctions where partial volume blurs margins. That work only visualized the effect after the fact. We turn the observation into a quantitative, testable model.

Three multi-rater methods supply the main comparison. OMBA-UNet uses a decoder per rater. MrPrism iterates between a calibrated mask and rater confidence maps. The Latent Doctor Model learns a latent rater-style distribution. All three treat every pixel of disagreement as rater behavior, so none can say how their predicted distribution should change when the slice thickness doubles. We impose that change through physics.

Two lines of work supply the physics side. Fuzzy radiomics weights boundary voxels by a fixed Gaussian matched to scanner resolution and reports AUC gains of +4.7% to +10.4% over binary masks. That work had no multi-rater data and so cannot ask whether physics accounts for all boundary ambiguity. Our physics-only ablation is essentially its weighting applied to segmentation. Recon-all-clinical and the contrast-agnostic claustrum method supply the tools we reuse for the latent sharp boundary: signed distance prediction and training on synthetic scans with randomized resolution. Recon-all-clinical reports surface errors generally below 0.4 mm even at 6 mm slices, yet also reports muted aging signals at those thicknesses. That is the measurement attenuation our downstream experiment targets.

DiFF argues that the best fused label is the one that most helps diagnosis, reporting up to 2.73% AUC gains on 2D images. We read this as a constraint on our design. If DiFF is right, optimizing for agreement with raters is not enough, so we evaluate the latent boundary on downstream clinical correlation as well as on distribution matching.

On the multimodal side, PECon and MFM-Geom fuse imaging with health-record data under single consensus labels. PECon in fact excluded subsegmental emboli, where blur and discordance are worst. We do not propose a new fusion architecture. Clinical context enters only through $\sigma_{\text{judg}}$, which makes a sharp prediction: context should shift judgment disagreement but leave the physics band untouched.

Research Program

The first stage is a measurement study that needs no new model. On the QUBIQ tasks, we estimate a smooth reference boundary from the mean rater map and measure the local width of the disagreement band. Width here means the distance between the 0.1 and 0.9 rater-agreement contours along the normal. We then regress this width on $w_{\text{phys}}(n)$, computed from voxel spacing and boundary orientation. The tasks are prostate, brain growth and brain tumor MRI, and kidney, pancreas and pancreatic lesion CT. The key output is the fraction of band-width variance explained by orientation-projected resolution, reported per task. A near-zero fraction falsifies the premise, and we would stop there.

The second stage builds the decomposed model. A single 3D network predicts a signed distance map, pretrained with randomized synthetic resolutions in the style of SynthSeg. A small head predicts $\sigma_{\text{judg}}$. Training uses a likelihood on the individual rater masks under the equation above. The physics term is computed analytically from the header. The point-spread width is either taken from scanner specifications or fit as one global scalar per modality.

The third stage tests clinical context. The file documents no dataset with multi-rater masks, clinical variables and resolution variation together, so we add a targeted annotation study. Four to six radiologists outline lesions on a subset of PI-CAI prostate MRI, once without and once with age, PSA and prostate volume shown, in randomized order with a washout period. Lesions are chosen because organ outlines are unlikely to depend on lab values. Context should change $\sigma_{\text{judg}}$, and possibly the latent boundary location, but not $w_{\text{phys}}$.

The fourth stage tests clinical correlation. We take 1 mm ADNI T1 scans, used by DIVE and Recon-all-clinical, and re-slice them synthetically to 3, 5 and 6 mm. At each thickness we compute hippocampal volume and regional cortical thickness from four sources: a binary segmentation, the mean soft map, Recon-all-clinical, and our latent boundary. For each, we track how the correlation with MMSE and CDR-SOB weakens relative to the native 1 mm value.

Baselines

The naive reference is a single U-Net trained on majority-vote masks, with no uncertainty. It sets the floor for distribution matching and is the standard pipeline in correlation studies. The consensus-versus-panel results in More is more suggest it will be poorly calibrated: F1 of 72.9% against 78.2% for the virtual panel, and calibration error of 0.183 against 0.050. That is pathology, though, not tomography, so we measure it ourselves rather than assume it.

The strongest existing competitor on QUBIQ is a deep ensemble of 3D U-Nets, which the challenge paper identifies as beating more complex probabilistic models. The top teams reached average Dice between 0.80 and 0.85; the file reports no per-task Q-Dice for the winning ensemble. We also run OMBA-UNet, which beat PHiSeg and the probabilistic U-Net on 5 of 7 QUBIQ tasks but takes 0.34 s per inference against 0.02 s for a plain U-Net, and MrPrism, for which the file gives no numeric QUBIQ Dice. All methods share the same backbone width, augmentation, training splits, and roughly equal hyperparameter search budget in GPU-hours. The ensemble is allowed its natural extra compute, and we report compute alongside accuracy.

Two ablations isolate the key ingredient. The physics-only model sets $\sigma_{\text{judg}}=0$, which is fuzzy-radiomics-style weighting with a learned latent boundary. The physics-free model drops $w_{\text{phys}}$ and learns all spread. The physics-free model, given voxel spacing as an extra input, is the critical control.

Beating the baselines has two parts, both pre-specified. In-distribution, Q-Dice must fall within noise of the ensemble at single-model cost. Under resolution shift, the model is trained only on scans resampled to one slice thickness and tested at others. There it must show clearly lower error in predicted band width and higher Q-Dice than the ensemble, OMBA-UNet and the spacing-conditioned control. In the correlation study, it must lose less correlation with MMSE and CDR-SOB at 6 mm than Recon-all-clinical. The file reports no correlation magnitudes for DIVE or Recon-all-clinical on ADNI, so all reference values will be recomputed on our splits.

Why not just…?

Why not just train one network on the averaged soft labels? In distribution this is a real threat, and we expect it to roughly tie on Q-Dice. A network that copies the band width seen in training cannot say how the band should change at a resolution it has never seen, and it cannot separate the two sources of disagreement. The resolution-shift test settles this. If the soft-label network extrapolates as well, our accuracy claim fails and only the measurement study stands.

Why not just use fixed resolution-matched fuzzy masks, as fuzzy radiomics does? That is our physics-only ablation. Fuzzy radiomics shows the weighting helps prediction, but it assumes all boundary ambiguity is blur. If stage one finds a large residual, especially on lesions, and if the residual responds to clinical context in the annotation study, then physics-only is provably incomplete. If the residual is negligible, fuzzy masks are sufficient, and we will report that.

Why not just feed slice thickness to an ensemble and let it learn the rest? This is the most serious alternative, because a flexible network might learn the orientation-projected blur law on its own. We include it as the spacing-conditioned control under the same budget. If it matches our model under resolution shift, the explicit forward model adds interpretability but no accuracy. The contribution then narrows to the decomposition evidence and the context experiment, which a spacing-conditioned black box cannot provide because it has no separate judgment term to inspect.

Decisive Checks

The idea lives or dies on three results. First, the regression of band width on orientation-projected resolution must explain a substantial share of variance on QUBIQ, with lesion tasks expected to show more residual than organ tasks. Second, the model must hold its Q-Dice at held-out slice thicknesses better than the ensemble and the spacing-conditioned control. Third, in the prostate annotation study, showing clinical context must shift the judgment spread while leaving the physics band statistically unchanged. A secondary but clinically meaningful result is a flatter correlation-attenuation curve on re-sliced ADNI. That would mean the many thick-slice hospital scans now excluded from correlation studies could be included without diluting the link between brain measurements and symptoms.