How Much of a Muscle-and-Marrow Aging Clock Is Annotator Style?

MRI can measure how much of a tissue is fat, not just how bright it looks. The quantity is the proton density fat fraction (PDFF): the share of MRI-visible hydrogen signal coming from fat rather than water, after correcting for known physical biases. Two tissues show strong, sex-dependent fatty change with age: the bone marrow of the lumbar vertebrae and the muscles beside the spine. Neither appears in the multi-organ "aging clocks" that turn imaging measurements into a predicted biological age. To read a PDFF value, someone has to outline the vertebra or muscle on every slice, and human outliners do this in a characteristic way. They draw conservatively inside the muscle edge to avoid the fat around it. This note proposes to build a PDFF-based musculoskeletal aging clock and to treat outline variability as a measured quantity. The clock is trained to be insensitive to it. The main deliverable is a number clinicians need before they could act on such a score: how much of a person's "age gap" (predicted minus calendar age) is biology, and how much is the result of who drew the contour.

The question matters because the readouts nearly coincide. In the normative lumbar cohort of Anatomical Variation of Age-Related Changes in Vertebral Bone Marrow Composition, female marrow PDFF rises from about 27% in the 20s to 48.8% in the 60s. That is roughly half a PDFF point per year (our back-of-envelope arithmetic from the decade means). The only reported automated-versus-manual comparison, Automated assessment of paraspinal muscle fat composition, found PDFF discrepancies of 0.02% to 0.58% on three healthy subjects. Divided by that slope, the upper end of the discrepancy is on the order of a year of apparent aging from a single feature. In atrophic muscle, where fat collects at the interfaces that conservative outlines exclude, the discrepancy is likely larger. Nobody has measured how this propagates into an age gap.

Core Claim

A musculoskeletal biological age built from vertebral marrow and paraspinal muscle PDFF can be made reportable. Reportable here means that the spread of age gaps between people clearly exceeds the spread within one person across plausible outlines. Getting there requires measuring segmentation variability explicitly and penalizing clock features that are sensitive to it. Plugging automated PDFF into a standard sparse regression is not enough. The claim can be falsified: if a plain automated pipeline already reaches the same reliability, the penalty is unnecessary, and that finding is itself useful.

This differs from the closest existing work in three ways. The organ clocks of Imaging-based organ-specific aging clock predicts human diseases and mortality use LASSO on 1,777 UK Biobank imaging measures, and Multi-organ MRI digitizes biological aging clocks builds seven-organ MRI age gaps with LASSO and linear support vector regression. Both treat their input measurements as fixed truth, and neither includes marrow or paraspinal PDFF. The multi-rater methods DiFF (Calibrate the inter-observer segmentation uncertainty via diagnosis-first principle) and Pionono (Probabilistic Modeling of Inter- and Intra-observer Variability) model rater disagreement only on 2D images with discrete diagnostic targets. We borrow Pionono's idea of a per-rater style distribution as a tool for generating contours. Our target, however, is a continuous age prediction from 3D quantitative maps, and the robustness goal is placed on the clock rather than on the mask.

Research Program

The work has four parts.

Measure real rater variability. No PDFF dataset in the file has more than one independent annotator. MyoSegmenTUM spine (reference database) contains 54 healthy subjects with L1–L5 and bilateral psoas and erector spinae. One radiologist segmented all of it, at up to 100 minutes per spine. The first concrete step is to have three additional readers of differing experience (radiologist, resident, trained student) independently re-segment a stratified subset of about 25 MyoSegmenTUM subjects. This mirrors the student-plus-supervisor arrangement in the LION study (nnU-Net abdominal PDFF). We will also explicitly record whether each reader traces inside or on the fascia.

Generate plausible contours for every subject. We cannot pay four readers to annotate whole cohorts. We will therefore produce, for each subject, a set of plausible segmentations from two generators. The first is cheap: morphological erosion and dilation of an automated mask by one to three voxels, plus an "inside-the-fascia" erosion matched to the measured human habit. The second is expensive: a 3D adaptation of Pionono's rater-style latent model, trained on the multi-rater subset. An ablation decides whether the expensive generator earns its place.

Train a clock that ignores contour style. Write the clock as a linear model $f(x)=w^\top x+b$ on features $x$. The features are mean PDFF per level and per muscle, the L1–L4 marrow gradient, $R_2^*$ (the signal decay rate), volumes, and simple texture statistics of the kind studied in Vertebral Bone Marrow Heterogeneity Using Texture Analysis. For subject $i$ with chronological age $a_i$, mean features $\bar x_i$ across plausible contours, and feature covariance $\Sigma_i$ across those contours, we fit

$$\min_{w,b}\ \sum_i \big(a_i - w^\top \bar x_i - b\big)^2 + \lambda \lVert w\rVert_1 + \gamma\, w^\top \Big(\sum_i \Sigma_i\Big) w .$$

The last term equals the total contour-induced variance of the predicted age, so $\gamma$ trades accuracy against outline sensitivity. When $\gamma = 0$, this reduces to the LASSO used by existing organ clocks. Clocks are fit separately by sex, because the trajectories diverge after menopause.

Define what "reportable" means. This is where the evidence-practice gap enters, as a constraint rather than a trial. Implementation gap and influencing factors of exercise prescription for older adults found that 95% of clinicians endorse exercise for older adults, yet written prescriptions occur in only 9% and 4% of cases. Respondents cited missing integration into routine care and lack of objective stratification. An artificial intelligence-powered learning health system shows that automated scores change practice when they are embedded and trusted. Such a score cannot depend on who drew the outline, and it cannot require 100 minutes of tracing. We operationalize this with two quantities. The first is the age-gap intraclass correlation, between-subject variance divided by total variance, where the within-subject component comes from real raters. The second is the minimal detectable change in age gap, in years. The score must run end to end without manual input. Running a clinical deployment trial is out of scope. Instead, we will produce the reliability numbers that any such trial would need first.

Data and Feasibility

Training uses healthy subjects with a broad age range: the 156-volunteer normative lumbar cohort (manual L1–L4 masks, 20–79 years) combined with MyoSegmenTUM spine. The two were acquired with different multi-echo protocols. A PDFF clock that transfers between them is itself a test of the claim that PDFF is scanner-independent. Automated segmentation uses nnU-Net with water, fat and $T_2^*$ inputs, following the LION recipe. That recipe reported Dice of 0.91–0.97, where Dice is the overlap between automated and manual masks. Out-of-distribution evaluation uses the LION obese cohort and its pre/post-diet scans. Atrophic muscle is tested with the four neuromuscular patients in thigh MyoSegmenTUM, where the interface-fat concern is sharpest. These cohorts are small, so the claim concerns reliability and transfer. We are not claiming that a definitive population clock is achievable at this scale.

Baselines

The naive reference is chronological age alone. This means an age gap of zero for everyone, or equivalently predicting the training-set mean age. Every clock must beat it on mean absolute error under identical cross-validation folds. Its age-gap reliability is trivially perfect, which is exactly why reliability must be reported alongside accuracy.

The strongest competitor is the standard organ-clock pipeline transplanted to this tissue. It consists of nnU-Net trained on the single-radiologist masks, mean PDFF and volume per structure, and LASSO (and linear SVR) as in Ren et al. and MRIBAG. It is strongest because it is what anyone would build first, and the Baum discrepancy figures suggest mean PDFF may already be nearly outline-invariant. It will receive the same features, folds and hyperparameter search budget as our method; only $\gamma$ differs. For reference, MRIBAG reports a mean absolute error of about 5 years across its seven organs, and Ren et al. report age correlations of R = 0.81 (brain gray matter) and R = 0.72 (heart). These come from much larger cohorts and different organs, and there is no reported result found on Lacuna for a marrow or paraspinal PDFF aging clock. Beating this baseline means a statistically higher age-gap ICC across real raters, with mean absolute error no worse than about half a year (about one PDFF-slope unit). Alternatively, it means equal ICC with better transfer to LION or the atrophic thigh cases.

A third baseline mimics human style: features computed from eroded masks only. The key ablation sets $\gamma=0$ while keeping the generated-contour averaging $\bar x_i$. This separates the benefit of averaging over contours from the benefit of penalizing sensitivity. A second ablation swaps the Pionono-style generator for plain morphological perturbation.

Why not just…?

Why not just train nnU-Net and feed mean PDFF into LASSO? This is the real threat. Baum et al. found PDFF differences under 0.6% despite clear volume differences, which suggests that averaging fat fraction over a region is forgiving. Their evidence comes from three young healthy subjects, though, and the thigh database explicitly warns that interface exclusion could matter in atrophic muscle. The $\gamma=0$ ablation and the LION and atrophic evaluations settle this directly. If the plain pipeline matches our ICC everywhere, we will report that segmentation variability is negligible for PDFF clocks and recommend the simple pipeline. That would be a useful negative result that existing clock papers have assumed but never tested.

Why not just erode every mask so humans and machines agree? Erosion standardizes style, but it throws away interfacial fat, which may be where atrophy shows up first. Erosion might also make texture and volume features less informative. The eroded-mask baseline tests this. If it matches our method on both accuracy and reliability, erosion is the better recommendation because it is simpler.

Why not just use chronological age, or an existing body-composition clock? Calendar age carries no information about individual tissue decline, while age-gap clocks have predicted organ-specific disease beyond it in Ren et al.. The honest caveat is outcome validity. ADIMOS found no link between marrow PDFF and incident fragility fractures, whereas Leonhardt et al. report associations with vertebral fractures. We therefore make reliability the primary endpoint. Outcome associations are treated as preregistered secondary analyses where longitudinal fracture cohorts can be accessed. A null result there would be reported, not explained away.

Why not apply DiFF directly? DiFF needs a downstream label to weight raters against and was built for classification. Here the target is age, so "expertness" learned this way would reward contours that happen to predict age. That is circular, and with a few hundred subjects it risks overfitting. Our penalty uses only the variance across contours, which does not depend on the target.

Decisive Checks

The first check is whether, on the multi-rater MyoSegmenTUM subset, the robust clock's age-gap ICC exceeds the plain pipeline's, and whether its minimal detectable change falls below the size of age gaps seen between people. The second check is whether the advantage grows from healthy subjects to the obese LION cohort and the atrophic thigh cases. This would confirm the interface-fat mechanism rather than noise. The third check is whether a clock trained on one acquisition protocol transfers to the other without large mean absolute error inflation. If the first check fails at small $\gamma$ and succeeds only at a large accuracy cost, the conclusion is that this tissue's age signal and its outline sensitivity cannot be separated. Future clinical tools should then report PDFF with an uncertainty band rather than as a single age gap.

References

  1. Anatomical Variation of Age-Related Changes in Vertebral Bone Marrow Composition Using Chemical Shift Encoding-Based Water–Fat Magnetic Resonance Imaging
  2. Automated assessment of paraspinal muscle fat composition based on the segmentation of chemical shift encoding-based water/fat-separated images
  3. Imaging-based organ-specific aging clock predicts human diseases and mortality
  4. Multi-organ MRI digitizes biological aging clocks across proteomics, metabolomics, and genetics
  5. Calibrate the Inter-Observer Segmentation Uncertainty via Diagnosis-First Principle
  6. Probabilistic Modeling of Inter- and Intra-observer Variability in Medical Image Segmentation
  7. Lumbar muscle and vertebral bodies segmentation of chemical shift encoding-based water-fat MRI: the reference database MyoSegmenTUM spine
  8. Evaluating Sex-specific Differences in Abdominal Fat Volume and Proton Density Fat Fraction at MRI Using Automated nnU-Net–based Segmentation
  9. Vertebral Bone Marrow Heterogeneity Using Texture Analysis of Chemical Shift Encoding-Based MRI: Variations in Age, Sex, and Anatomical Location
  10. Implementation gap and influencing factors of exercise prescription for older adults: a large-scale survey of healthcare professionals in China
  11. An artificial intelligence-powered learning health system to improve sepsis detection and quality of care: a before-and-after study
  12. Thigh muscle segmentation of chemical shift encoding-based water-fat magnetic resonance images: The reference database MyoSegmenTUM
  13. Marrow Adiposity Content and Composition Are Not Associated With Incident Fragility Fractures in Postmenopausal Women: The ADIMOS Fracture Study
  14. Associations of incidental vertebral fractures and longitudinal changes of MR–based proton density fat fraction and T2* measurements of vertebral bone marrow