A radiomics model reduces a tumor on a scan to hundreds of numbers describing its shape, brightness and texture, then learns to classify from those numbers. When such a model is moved to a new hospital, two things usually change at once. The scanners change, and that alters the numbers. The fraction of patients who actually have the disease changes too, for example between a referral clinic and a screening program. Standard external validation reports one aggregate score, typically AUC, the area under the curve that measures how well a model ranks sick patients above healthy ones. That score does not separate these two causes, and because AUC ignores prevalence it cannot show the failure clinicians notice first: the fraction of positive calls that are real collapses. This note proposes a forecasting tool. Before deploying a model at a new site, it predicts the model's precision there using only two inputs: a small stability study describing how the target site's scanner protocol perturbs each feature, and the site's expected prevalence. We then check these forecasts against real held-out sites.
The central observation is that the two shifts interact. Texture features are known to be fragile across reconstruction settings. In A comparative analysis of image harmonization techniques in mitigating differences in CT acquisition and reconstruction, their concordance across dose and kernel conditions is about 0.50, compared with about 0.97 for intensity features. That fragility mostly moves the false positive rate. On Model Evaluation Under Non-constant Class Imbalance shows that small errors in false positive rate are strongly magnified in precision when prevalence is low. The consequence is that "how stable must a feature be?" has no single answer. A texture feature that is harmless in a 50%-prevalence biopsy cohort can be ruinous in a 2%-prevalence screening population. We want to measure that dependence and turn it into a pre-deployment check.
Core Claim
A model's deployed precision at an unseen center can be forecast by combining two things. The first is the model's error rates on source data after feature-specific acquisition noise is injected. The second is a Bayes projection of those error rates to the target prevalence. Write $\eta$ for target prevalence and $\widetilde{\mathrm{TPR}}, \widetilde{\mathrm{FPR}}$ for the true and false positive rates measured on source test cases whose features have been perturbed with the target protocol's estimated noise. The forecast is
$$ \widehat{\mathrm{Prec}}(\eta) = \frac{\widetilde{\mathrm{TPR}}\,\eta}{\widetilde{\mathrm{TPR}}\,\eta + \widetilde{\mathrm{FPR}}\,(1-\eta)} . $$
The sensitivity of this quantity to false positive rate scales roughly as $(1-\eta)/\eta$ for small $\eta$, which follows directly from differentiating the expression. We therefore make a falsifiable prediction. The ranking of competing feature-handling strategies (keep all features, hard-filter unstable ones, noise-augmented training, image harmonization) should reverse as $\eta$ falls. It should reverse at a point we can predict from each feature set's noise-induced false positive rate. The new element is neither the prevalence projection, which is the $P^3$ curve, nor the noise model, which borrows from DAFIT. It is composing the two into a quantitative forecast for a specific site and validating that forecast against real site shifts.
Research Program
The tool reuses two existing methods. From Optimal Statistical Incorporation of Independent Feature Stability Information into Radiomics Studies we take the idea of summarizing each feature's instability as a mean shift and variance estimated in a side study. DAFIT uses this at training time, synthesizing noisy copies of training samples so the classifier learns to discount fragile features. We use the same per-feature noise model at evaluation time, to simulate what the target site's scanner will do to held-out cases. From On Model Evaluation Under Non-constant Class Imbalance we take the prevalence projection. It keeps every negative case and projects precision through Bayes' rule instead of subsampling negatives. The authors show subsampling inflates variance because of false-positive-rate instability.
Our extension composes the two and adds uncertainty. We bootstrap over patients and over side-study noise estimates, so the forecast has an interval instead of a single point. We also extend the noise model from independent per-feature noise to a low-rank correlated perturbation. Kernel changes move whole families of texture statistics together, and an independence assumption would likely underestimate the resulting shift in false positive rate. Whether the correlated version is needed is itself tested below.
The side-study noise estimates come from two sources. The first is multi-reader segmentation variability within LIDC-IDRI, the source DAFIT used. The second is acquisition variability. We would obtain it by replicating the nine-condition dose-and-kernel protocol of A comparative analysis of image harmonization techniques in mitigating differences in CT acquisition and reconstruction on whatever raw-data scans we can access. The fallback is image-domain simulation of kernel sharpening and dose noise on LIDC volumes. The in-house cohort of 100 scans used in that paper is not public, so this dependency is flagged as the main practical risk.
The program has one explicit blind spot. Forecasts only account for acquisition and prevalence shift. Re-thinking and Re-labeling LIDC-IDRI for Robust Pulmonary Cancer Prediction shows that radiologist malignancy scores carry a strong conservatism bias: models trained on them reach 0.97 sensitivity but only 0.23 specificity. A site whose labeling habits differ will produce forecast residuals that the tool cannot explain. We treat those residuals as a measurement of labeling shift and do not tune them away. This matters for honest interpretation, because the forecast's error on a biopsy-labeled external site partly reflects label-definition shift.
Baselines
The naive reference is standard external validation as practiced in multi-center radiomics. It reports AUC on the source test split and assumes precision transfers. This is how Non-invasive decision support for NSCLC treatment using PET/CT radiomics summarizes cross-center performance, with AUCs of 0.81 to 0.86. The corresponding "forecast" is source-split precision at source prevalence. Beating this baseline requires a lower absolute forecast error on target-site precision.
The strongest existing competitor is the $P^3$ projection alone. It uses unperturbed source error rates projected to the target prevalence, so it corrects for prevalence but not for acquisition. This is also the ablation that isolates our key ingredient, the acquisition-noise injection. We found no reported result on Lacuna for $P^3$ applied to LIDC-IDRI or any 3D radiomic cohort. We will therefore run it ourselves on identical models, splits and bootstrap resamples. The only difference from the full tool will be the absence of perturbation. We count it as beaten if the full tool's forecast error on held-out sites is lower with bootstrap confidence intervals that exclude zero difference. We also require the full tool to predict ranking reversals between strategies that $P^3$ alone misses.
A second ablation replaces correlated noise with independent per-feature noise, which is the DAFIT assumption. It tests whether texture-family correlations matter.
We also compare against empirical per-site recalibration. Each held-out site's features are z-scored using that site's own unlabeled scans, and then $P^3$ is applied. This baseline has access to target data our tool does not need, so it acts as an upper reference.
For the classifiers being forecast, we use literature-grounded models as the objects of study. The first is a radiomics random forest with all features. The second is the same model with hard stability filtering. The third is DAFIT training. The fourth is SNGAN-harmonized inputs; SNGAN reached a radiomic concordance of 0.969 ± 0.009 in A comparative analysis of image harmonization techniques in mitigating differences in CT acquisition and reconstruction. The fifth is a 3DSiam-with-reweighting representation from Imbalance-Aware Self-supervised Learning for 3D Radiomic Representations, which reports 0.920 sensitivity on BraTS against 0.888 for supervised training. For reference on LIDC, the biopsy-relabeled model in Re-thinking and Re-labeling LIDC-IDRI for Robust Pulmonary Cancer Prediction reaches 0.67 sensitivity and 0.66 specificity. All models get the same feature extraction, the same hyperparameter budget and the same splits.
Why not just…?
Why not just run leave-one-center-out validation and report the result? Leave-one-center-out validation is the gold standard where it is possible. The impact of multicentric datasets for the automated tumor delineation in primary prostate cancer using convolutional neural networks on 18F-PSMA-1007 PET uses it well, with a median Dice of 0.74. It has two limits. It requires labeled data from the target site, which is exactly what a hospital deciding whether to adopt a model lacks. Its aggregate metrics are also measured at the held-out site's own prevalence, so they say nothing about a screening deployment at a much lower base rate. We use it as the ground truth that forecasts are scored against, not as a competitor.
Why not just harmonize the images and assume the problem is solved? The same comparative study shows harmonization is conditional. BM3D degraded reproducibility on already-clean smooth-kernel, full-dose scans, and methods optimizing visual similarity diverged from those preserving feature values. Harmonization is one of the strategies our tool forecasts, not a replacement for it. If SNGAN-harmonized models show negligible noise-induced false-positive-rate change, the forecast will simply say so. That would be a useful finding, and it would shrink the claim to "harmonize, then project prevalence."
Why not just z-score features per site and project prevalence? This is the most serious threat. It is cheap, and if unlabeled target scans are available it may match our tool. We include it as the upper-reference baseline. If it equals our forecast accuracy, the contribution narrows to settings without target scans, such as procurement decisions or new scanner purchases, and we will report that narrowing plainly. Per-site standardization also cannot separate biological case-mix differences from scanner effects. Our side-study noise model does not share this weakness. The experiments test whether that distinction affects forecast error.
Why not just use $P^3$ directly? It is the ablation described above. Our hypothesis stands or falls on whether adding acquisition noise reduces forecast error at low prevalence specifically.
Proposed Experiments
The primary testbed is LIDC-IDRI. We split it by scanner manufacturer into pseudo-centers and hold out one manufacturer at a time. This mirrors the property-based splits DAFIT used, but here the splits are scored as deployment forecasts. SCH-LND serves as a genuinely external site with biopsy-confirmed labels at 50% prevalence. Precision is then projected down to screening-like prevalences between 1% and 10%, with realized values checked by the $P^3$ projection on the full held-out set. NSCLC-radiomics, with its 2:1:6 stage skew, provides a multi-class stress test, handled with one-versus-rest projections.
Metrics are three. The first is absolute error between forecast and realized precision at each held-out site and prevalence. The second is coverage of the bootstrap intervals. The third is Kendall tau between forecast and realized rankings of the five feature-handling strategies.
Three results would be decisive. First, the full forecast should beat $P^3$ alone on held-out manufacturers, and the gap should widen as $\eta$ falls, following the $(1-\eta)/\eta$ scaling. If the gap stays flat, the interaction claim is wrong. Second, at least one predicted ranking reversal should appear in realized results: for example, hard filtering losing to all-features at 50% prevalence but winning at 2%. Failing to observe any reversal would mean feature-stability thresholds can safely be chosen once, independent of prevalence. That would be a useful negative result. Third, on SCH-LND, the forecast residual beyond the acquisition-and-prevalence prediction is compared with the residual expected from the known radiologist-versus-biopsy label bias. This tells us how much of any external-site gap is due to label definition rather than scanners, which is the confound current multi-center radiomics studies leave unresolved.
References
- A comparative analysis of image harmonization techniques in mitigating differences in CT acquisition and reconstruction
- On Model Evaluation Under Non-constant Class Imbalance
- Optimal Statistical Incorporation of Independent Feature Stability Information into Radiomics Studies
- Re-thinking and Re-labeling LIDC-IDRI for Robust Pulmonary Cancer Prediction
- Non-invasive decision support for NSCLC treatment using PET/CT radiomics
- Imbalance-Aware Self-supervised Learning for 3D Radiomic Representations
- The impact of multicentric datasets for the automated tumor delineation in primary prostate cancer using convolutional neural networks on 18F-PSMA-1007 PET