When several experts outline the same brain tumor, their contours rarely match. The largest disagreements fall at the edge of the swollen tissue around the tumor, known as peritumoral edema. Current machine-learning models of this disagreement treat each expert as a black box with a personal "style", learned as a vector of hidden numbers. This proposal tests a physical explanation instead. Diffusion MRI measures how freely water moves in each image voxel, and a two-compartment model can split each voxel into a fraction of freely moving extracellular fluid (the "free-water fraction", $f_{FW}$) and a remainder that behaves like structured tissue. Our hypothesis is that much of the expert disagreement at tumor margins comes from one source: how much fluid each expert tolerates before calling a voxel "lesion". If that holds, a rater can be described by two or three interpretable numbers on a fluid axis, rather than by an opaque latent code.
The payoff is practical. First, disagreement becomes explainable: the model can report that rater A includes any voxel above 40% free water while rater B stops at 60%. Second, a new rater could be calibrated from one or two annotated cases. Third, the model is cheap enough to run on full 3D volumes, which is where the heavy Bayesian multi-rater models struggle. The hypothesis can also fail cleanly. If ordinary FLAIR brightness, the image experts actually contour on, explains disagreement just as well as $f_{FW}$, then the diffusion physics adds nothing, and we will say so.
Core Claim
Our claim is that inter-rater disagreement at glioma edema margins lies mostly along one physically defined direction, voxel free-water fraction. We further claim that $f_{FW}$ explains this disagreement better than conventional image intensity does. We will test this in two ways. The first is a variance decomposition on new multi-rater annotations of diffusion MRI tumor scans. The second is a rater model whose per-rater parameters live on that fluid axis. This model should match flexible latent-rater models at predicting each expert's contour, and it should beat them when calibrating a new expert from few examples.
Where This Sits
Two literatures meet here without touching. The first is free-water modeling. The standard model treats the diffusion signal as a mixture of isotropic water (diffusivity about $3\times10^{-3}$ mm²/s) and a tissue tensor. This lets fluid-driven drops in fractional anisotropy (FA, how directional water motion is) be separated from real tissue change. Two papers motivate our work most directly:
- Metz et al. trained a neural network on synthetic signals to correct free water in single-shell diffusion data from 35 glioblastoma patients. Corrected FA predicted recurrence inside edema with an area under the curve (AUC) of 0.90, against 0.77 for uncorrected FA. However, the regions of interest were drawn by hand, rater variability was never examined, and integration with segmentation was left as future work.
- Yao et al. built a deep free-water estimator with spherical convolutions and acquisition-adaptive heads. On HCP young-adult data it reports a free-water-fraction RMSE of 1.97×10⁻², against 3.62×10⁻² for conventional single-shell fitting. On brain tumor connectomics data it recovers tractography streamlines around tumors, but it never analyzes delineations.
We reuse these estimators as the source of $f_{FW}$. We do not propose a new one.
The second literature models rater disagreement. Four works supply our baselines and constrain our design:
- Pionono gives each rater a Gaussian in an 8-dimensional latent space, with the mean capturing bias and the variance capturing inconsistency. It reports Cohen's kappa of 0.758 on Gleason 2019.
- OMBA-UNet gives each rater a Bayesian decoder. It beats Probabilistic U-Net and PHiSeg on 5 of 7 QUBIQ tasks, but its inference is seventeen times slower than a U-Net (0.34 s against 0.02 s).
- QUBIQ found that plain deterministic ensembles were among the strongest entries, with top teams averaging Dice between 0.80 and 0.85, and defined the thresholded Q-Dice metric.
All of these models learn rater bias as an unlabeled latent quantity from structural images alone. We replace the free latent with a constrained, physically anchored one. The review by Liu et al. observed that tumor boundaries are fuzzy because edema and infiltrating cells mix, and it named diffusion markers as a way forward. We turn that remark into a testable, quantitative hypothesis.
Research Program
The first obstacle is data. No resource in our file pairs diffusion MRI with multiple independent expert tumor contours. QUBIQ's brain tumor task is structural MRI only, and the Metz cohort is single-center and not public. We will therefore create the paired resource.
Annotation. We will use the preoperative scans of the Brain Tumor Connectomics data used by Yao et al.. Five neuroradiologists or trained annotators will independently outline the edema-plus-tumor region and the enhancing core on the structural images, following the usual clinical practice of contouring on FLAIR and contrast-enhanced T1. Each rater will re-annotate a random 20% of cases after a washout period, so that within-rater inconsistency is measured directly.
Free-water maps. We will compute $f_{FW}$ and free-water-corrected FA with the deep estimator of Yao et al. and with conventional fitting. All results will be reported under both, so that the conclusions do not hinge on one estimator's errors.
Stage one: measurement. At every margin voxel we will compute the per-voxel disagreement (the entropy of the rater labels). We will then ask how much of it is explained by each of the following: $f_{FW}$, FLAIR intensity, uncorrected mean diffusivity, and distance to the consensus boundary. The key quantity is the extra variance explained by $f_{FW}$ once FLAIR intensity and distance are already accounted for, estimated with mixed models that include a patient-level random effect. We will also test for a specific signature, rater ordering. If rater bias truly lies on a fluid axis, raters should rank consistently by the $f_{FW}$ level at which their contours stop, across patients.
Stage two: the fluid-axis rater model. A shared segmentation network $h_\theta$ produces a per-voxel score $h_\theta(x)_v$ from the images $x$. Rater $r$'s probability of labeling voxel $v$ as lesion is then
$$ p_r(y_v = 1 \mid x) = \sigma\!\left(\frac{h_\theta(x)_v + \beta_r f_{FW,v} - \tau_r}{s_r}\right), $$
where the symbols mean the following:
- $\sigma$ is the logistic function.
- $f_{FW,v}$ is the voxel's free-water fraction.
- $\beta_r$ is rater $r$'s sensitivity to fluid.
- $\tau_r$ is the rater's inclusion threshold.
- $s_r$ is a temperature capturing that rater's inconsistency.
Every rater thus costs three scalars. Inference is a single forward pass of $h_\theta$ followed by a cheap per-rater rescaling, so the model is practical on 3D volumes. Two variants will serve as controls. The first replaces $f_{FW}$ with FLAIR intensity, and the second uses the same three-scalar model with no physical covariate.
Baselines
Consensus reference. The naive reference point trains a single 3D U-Net on the STAPLE consensus. It outputs one mask, reused for every rater, and it will be scored against each rater's own contour. Pionono showed that consensus training discards meaningful disagreement, so any rater-aware model should beat it. Its value here is that it sets how much disagreement there is to explain at all.
Deterministic ensemble. This is the empirically strongest competitor, per QUBIQ: one U-Net per rater, plus fold ensembles. We will train it on the same inputs and splits, with the same epoch and hyperparameter search budget.
Learned-latent rater models. Pionono and OMBA-UNet are the strongest existing methods that model individual raters. They will share our backbone and receive the same tuning trials. Both will be run twice: with structural inputs only, and with $f_{FW}$ added as an input channel.
What we can compare against. Because the dataset is new, no reported result exists on Lacuna for any of these methods on multi-rater diffusion tumor data. The only published reference numbers come from different tasks: Dice between 0.80 and 0.85 for the top QUBIQ teams, and kappa of 0.758 for Pionono on Gleason 2019. Those numbers establish that the baselines are competitive, not a target on our data.
What counts as beating them. Our model beats the baselines if either of two things holds, with confidence intervals from 1,000 patient-level bootstrap resamples:
- It matches Pionono and OMBA-UNet on Q-Dice and generalized energy distance (GED, the distance between the distribution of predicted masks and the distribution of expert masks), within the bootstrap interval, while using orders of magnitude fewer rater parameters.
- It significantly outperforms them in the few-shot new-rater setting.
Ablations. The ablation that isolates the key ingredient swaps $f_{FW}$ for FLAIR intensity, for uncorrected mean diffusivity, and for $f_{FW}$ shuffled within the brain mask, keeping everything else identical.
Why not just…?
Why not just add the free-water map as an input channel to OMBA-UNet or an ensemble? This is the most serious threat. It may predict rater contours as well as our model. We run exactly that baseline. The difference is what the model can do beyond per-rater prediction. A free latent that happens to use $f_{FW}$ gives no interpretable rater parameter. It also cannot calibrate a new rater from one case, because a new decoder or latent must be fit. If the input-channel variant also wins the few-shot test, our structural constraint is unnecessary, and we will report the contribution as the attribution finding alone.
Why not just use FLAIR, since experts contour on it and it already highlights fluid? This is a real possibility. Raters look at FLAIR, so their disagreement may simply track FLAIR brightness. Metz et al. show that conventional sequences cannot separate infiltration from pure edema, but that result concerns recurrence, not rater behavior. Stage one's extra-variance test and the FLAIR-swap ablation settle the question directly. If FLAIR matches $f_{FW}$, we drop the diffusion component and keep an intensity-threshold rater model.
Why not just a deterministic ensemble with test-time sampling? QUBIQ shows that ensembles are hard to beat on calibration, so we include one at full strength. However, ensembles cannot represent a rater unseen during training, and they cost one network per member in 3D. The few-shot and latency comparisons show whether that matters in practice.
Decisive Checks
Stage one. The central result is the extra variance in margin disagreement explained by $f_{FW}$ beyond FLAIR and boundary distance. We will pre-register a threshold of at least five percentage points, holding under both free-water estimators. Consistent rater ordering by stopping level, measured by Kendall concordance across patients, would add supporting evidence.
Stage two. We will fit the rater parameters for a held-out rater from one, two, and five cases. We will then compare Dice against that rater's remaining contours for our model, Pionono and OMBA-UNet, where the new rater's latent or decoder is fine-tuned on the same cases.
Temporal validity. Parameters calibrated on first-session contours should predict each rater's washout re-annotations. In the same test, the fitted $s_r$ should correlate with measured intra-rater Dice.
Causal direction. A small crossover reader study will have raters re-contour a subset while also viewing $f_{FW}$ maps. The outcome is whether GED between raters shrinks, which would suggest the disagreement is resolvable information rather than irreducible taste.
References
- Predicting Glioblastoma Recurrence from Preoperative MR Scans Using Fractional-Anisotropy Maps with Free-Water Suppression
- Deep learning-based free-water correction for single-shell diffusion MRI