Counting Sintered Nanoparticles: Extended Likelihood Fits for Annealing Windows

Nanomaterial chemists heat their samples to make them pure and crystalline, but heating too much makes small particles fuse into large clumps, a process called sintering. That destroys surface area and catalytic activity. The usual way to find the best temperature is to anneal at a few temperatures, image a few hundred particles per sample in an electron microscope, bin their diameters into a histogram, and inspect the result. We propose instead to treat each imaged particle the way a particle physicist treats a detector event. The method writes down a probability model with separate components for "pristine particle," "sintered aggregate," and "unreacted residue." It fits that model to every particle's continuous measurements without binning, and it treats the number of particles found per imaged area as data in its own right. That last feature is what defines an extended maximum likelihood fit.

The physics behind this matters. When particles sinter, they disappear: two or more pristine particles become one aggregate, so the number of particles per unit area falls even if the size histogram looks only slightly broadened. An extended fit sees that drop in counts. When the fit is tied to conservation of metal volume across a whole temperature ladder, it can locate the onset of sintering with far fewer imaged particles than shape-only methods need. The concrete deliverable is an estimate of the sintering-onset temperature with honest error bars, computed from data labs already collect. That estimate can then guide where to anneal next.

Core Claim

Fit all temperatures of an annealing series jointly, with an extended likelihood that includes a size-dependent detection efficiency and a metal-volume conservation constraint. Such a fit should detect a small sintered sub-population and estimate the onset temperature more accurately, and with correctly calibrated uncertainty, than three alternatives at the same particle count: per-temperature histogram fits, hard morphological cuts, and ordinary mixture models that ignore counts. The new ingredient is not "use a mixture model on particle sizes," which any statistician would suggest. It is the coupling of absolute yields to particle volumes through mass balance, which only the extended form can express.

Grounding in Prior Work

The motivation comes from the materials side. Annealing ladders are standard and coarse. Ni-B nanoparticles were annealed at 200, 300, 400 and 500 °C, with 400 °C best and 500 °C causing aggregation and site collapse (Ultrafine Ni-B nanoparticles for efficient hydrogen evolution reaction). Cupric-tartrate decomposition gave pure Cu at 271 °C, while 350 °C produced severe aggregation (High-purity Cu nanocrystal synthesis by a dynamic decomposition method). In NiRu nanocrystals, ripening above 150 °C was suppressed by a 90 °C route (A low temperature organic synthesis of monodispersed NiRu nanocrystals for CO2 methanation). In all three, the onset of sintering lies somewhere in a 50–100 °C gap and is reported qualitatively. Each temperature is analyzed independently.

Autonomous synthesis platforms motivate the proposal in a different way. ScatterLab optimizes against a single mean squared error between measured and target scattering patterns. It names structural degeneracy as a limitation: mixtures of small and large particles can mimic a target average (Autonomous nanoparticle synthesis by design). The droplet platform of Two-step machine learning enables optimized nanoparticle synthesis likewise optimizes against an ensemble absorbance spectrum. Both show that black-box optimization works when the measured scalar is the right one. Neither resolves sub-populations, and that is the gap we target. We do not replace their optimizers. We supply a better measured quantity.

The method comes from particle physics. Extended unbinned fits jointly extract shapes and absolute yields of overlapping components. Two examples are the two-dimensional signal-versus-background fit of Update of the search for the neutrinoless decay tau -> mu gamma and the multi-variable fit that isolated a rare B decay at 3.9σ in Observation of B+ -> omega K+ and Search for Related B Decays Modes. Two further techniques supply our structure. The first is simultaneous fitting across datasets with shared parameters, as BESIII did across two collision energies (Observation of a Neutral Structure near the D(D)over-bar* Mass Threshold…). The second is embedding detector efficiencies directly in the likelihood, as PandaX-II did for photon and electron extraction efficiencies (Determination of responses of liquid xenon to low energy electron and nuclear recoils using a PandaX-II detector). Our temperature ladder plays the role of BESIII's energy points, and our microscope's poor sensitivity to sub-2 nm particles plays the role of PandaX's efficiency curves.

Signal estimation in on/off measurements including event-by-event variables also constrains the design. It shows that replacing hard cuts with per-event likelihoods gave a 15–20% precision gain at 10% signal-to-noise. That is a modest gain, which warns us not to expect miracles from unbinning alone.

Two microscopy papers supply inputs and bound the scope. The multislice surrogate of Improving Nanoparticle Size Estimation from Scanning Transmission Electron Micrographs with a Multislice Surrogate Model estimates individual particle sizes with 5.26% median absolute percentage error, and its errors are largest for 0–10-atom particles. We reuse its simulator to generate ground truth and to measure our detection-efficiency and resolution functions. That paper stops at per-particle sizes. We start where it stops, with the ensemble. Sequential Adaptive Detection for In-Situ Transmission Electron Microscopy (TEM) detects when a mean shift occurs in in-situ image sequences. It does not decompose populations, so we treat it as a competitor for the narrower "did something change" question.

The Model

The model covers an annealing series at temperatures $T_k$ with imaged areas $A_k$. Each segmented particle $i$ carries a measurement vector $x_i$ of projected diameter, circularity, and integrated contrast. Each component $j$ has a number density $\rho_j(T)$ per unit area and a shape density $P_j(x;\theta_j(T))$. The detection efficiency is $\varepsilon(x)$, measured from simulated micrographs. The joint log-likelihood is

$$\ln \mathcal{L} = \sum_k \Big[ -\sum_j A_k \rho_j(T_k)\, \bar\varepsilon_j(T_k) + \sum_{i \in k} \ln \sum_j A_k \rho_j(T_k)\, \varepsilon(x_i)\, P_j(x_i;\theta_j(T_k)) \Big],$$

where $\bar\varepsilon_j$ is the efficiency averaged over component $j$'s shape. The first term is the Poisson count term. It is the part an ordinary mixture model drops.

The temperatures are coupled in three ways. First, the sintered density switches on smoothly above an onset temperature $T_{\text{on}}$. We use a logistic form in $1/T$, motivated by the Arrhenius-type kinetics measured by TGA/DSC in the Cu study. Second, the pristine shape parameters drift slowly with temperature. Third, the total projected metal volume per area,

$$V(T) = \sum_j \rho_j(T)\, \mathbb{E}_j[v(x)],$$

is held equal to the as-synthesized value within a nuisance term for leaching. Here $v(x)$ is the volume inferred from a particle's measurements. The constraint is necessary because boron leaching is a known effect in Ni-B. Confidence intervals on $T_{\text{on}}$ and on the sintered fraction come from profile likelihood, with coverage checked by toy experiments.

Research Program

The work has three parts. First, we build the efficiency and resolution model. Using the multislice surrogate, we simulate high-angle annular dark-field images of supported particles with known size distributions and aggregation states. We run them through the same segmentation pipeline used on real data and tabulate $\varepsilon(x)$ and the measurement smearing.

Second, we run a synthetic study. Ground-truth annealing ladders are generated with a known $T_{\text{on}}$, sintered fractions from 1% to 30%, and 50 to 500 detected particles per temperature. All methods are scored on identical images. This is where the statistical claims are settled.

Third, we validate experimentally. We repeat the Ni-B anneal from the Ni-B paper on a finer ladder of 25 °C steps from 300 to 500 °C, image every sample, and measure hydrogen-evolution overpotential. The test is whether the fitted $T_{\text{on}}$ predicts the temperature at which electrochemical performance degrades. The published anchor is 114 mV at 10 mA cm⁻² for Ni-B-400.

As a secondary step, we use the fitted onset uncertainty to choose the next annealing temperature, picking the point that most shrinks the $T_{\text{on}}$ interval. We compare this against a uniform ladder at equal sample counts.

Baselines

The naive reference is the current practice. We fit a lognormal by least squares to a binned diameter histogram at each temperature. A sample counts as "sintered" when its fitted width or a second fitted mode exceeds a threshold, and $T_{\text{on}}$ is interpolated between the last clean and first sintered temperature. Bin width is tuned on held-out synthetic ladders, so this baseline gets the same tuning budget as our method.

The hard-cut baseline discards or counts particles by area and circularity thresholds and reports the fraction above the cut. Its thresholds are optimized on the same held-out ladders. Signal estimation in on/off measurements including event-by-event variables suggests this baseline loses precision but can be competitive at high signal-to-noise.

The strongest existing competitor is an ordinary unbinned two-component mixture fit at each temperature. It uses the same features and component families as our method but no count term, no efficiency correction, and no coupling across temperatures. Any statistician would propose exactly this, so beating it is the real test.

We also include an ensemble-scalar baseline in the spirit of ScatterLab: a volume-weighted mean size computed from the same images, then fed to a change-point rule. This mimics what an averaged scattering or absorbance measurement would report. Finally, adaptive CUSUM from the in-situ TEM detection paper runs on the per-temperature summary statistics.

No reported result was found on Lacuna for sintering-onset estimation or sintered-fraction recovery from microscopy under any of these methods. The nearest reported figures concern different tasks: 5.26% median error for single-particle sizing in the surrogate paper, and 41 experiments to reach a target structure in ScatterLab. These figures will not be used as comparison targets.

Our method beats a baseline if two things hold on the synthetic ladders at matched particle counts. Its root-mean-square error on $T_{\text{on}}$ must be lower, and its minimum detectable sintered fraction at 90% confidence must be lower. In addition, its 68% and 90% intervals must cover at the nominal rate, which least-squares histogram fits typically fail at low counts.

Three ablations isolate the ingredients: dropping the count term, dropping mass balance, and dropping the efficiency function. If the gain disappears when only the count term and mass balance are removed, the central claim is confirmed. If the gain survives without them, the claim reduces to "use a mixture model," and we will report it that way.

Why not just…?

Why not just fit lognormals to histograms, as everyone does? With 200–500 particles and a sintered tail of a few percent, the tail bins hold zero to three counts. Least-squares fitting there is biased, and the intervals are miscalibrated. Binning also throws away the joint diameter–circularity information that separates a large pristine particle from a two-particle neck. The synthetic study measures exactly how many particles the histogram method needs to match our onset accuracy. If that number is close to ours, the practical case weakens to calibrated error bars alone.

Why not just use an ordinary Gaussian mixture model on particle features? This is the real threat, and we have shaped the proposal around it. Shape-only mixtures already exploit unbinned information. Our argument is that sintering shows up first as a loss of particles with only slight broadening. A normalized mixture cannot see that loss, while the count term combined with volume conservation can. The ablation that removes only these two pieces settles the question directly. If it shows no gain, we will say the extended part is unnecessary.

Why not just run Bayesian optimization on a bulk measurement, as autonomous labs do? Optimization works when its target is the right one. ScatterLab's own authors flag structural degeneracy in averaged patterns (Autonomous nanoparticle synthesis by design). Our ensemble-scalar baseline tests that degeneracy on images with known mixtures. Where degeneracy appears, our fitted sintered fraction is a drop-in replacement objective for such optimizers rather than a rival to them.

Why not just use change-point detection? Adaptive CUSUM finds that a summary statistic shifted (Sequential Adaptive Detection for In-Situ Transmission Electron Microscopy (TEM)), but it returns no sintered fraction and no interval on the onset temperature. If it localizes the onset as well as our fit does, it is the cheaper tool for that sub-question, and the comparison will show whether that happens.

Decisive Checks

Three results decide the proposal. On synthetic ladders, the full fit should detect a sintered fraction about half the size of what the per-temperature mixture can detect at 200 particles per temperature, with nominal interval coverage, and the count-plus-mass-balance ablation should account for most of that gain. On the experimental Ni-B ladder, the fitted $T_{\text{on}}$ from roughly 200 particles per sample should agree, within its interval, with the onset estimated from a dense reference set of several thousand particles. The same $T_{\text{on}}$ should also precede the rise in hydrogen-evolution overpotential. Failure of either check would show that the physics-style likelihood adds bookkeeping without adding information.

References

  1. Ultrafine Ni-B nanoparticles for efficient hydrogen evolution reaction
  2. High-purity Cu nanocrystal synthesis by a dynamic decomposition method
  3. A low temperature organic synthesis of monodispersed NiRu nanocrystals for CO2 methanation
  4. Autonomous nanoparticle synthesis by design
  5. Two-step machine learning enables optimized nanoparticle synthesis
  6. Update of the search for the neutrinoless decay<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:mrow><mml:mover><mml:mrow><mml:mi>τ</mml:mi></mml:mrow><mml:mrow><mml:mo>→</mml:mo></mml:mrow></mml:mover></mml:mrow></mml:mrow><mml:mi>μ</mml:mi><mml:mi>γ</mml:mi></mml:math>
  7. Observation of<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:msup><mml:mrow><mml:mi mathvariant="italic">B</mml:mi></mml:mrow><mml:mrow><mml:mo>+</mml:mo></mml:mrow></mml:msup></mml:mrow><mml:mo>→</mml:mo><mml:mrow><mml:msup><mml:mrow><mml:mi mathvariant="italic">ω</mml:mi><mml:mi mathvariant="italic">K</mml:mi></mml:mrow><mml:mrow><mml:mo>+</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math>and Search for Related<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mi mathvariant="italic">B</mml:mi></mml:math>Decays Modes
  8. Observation of a Neutral Structure near the D(D)over-bar* Mass Threshold in e(+)e(-) -> (D(D)over-bar*)(0)pi(0) at root s=4.226 and 4.257 GeV
  9. Determination of responses of liquid xenon to low energy electron and nuclear recoils using a PandaX-II detector *
  10. Signal estimation in on/off measurements including event-by-event variables
  11. Improving Nanoparticle Size Estimation from Scanning Transmission Electron Micrographs with a Multislice Surrogate Model
  12. Sequential Adaptive Detection for In-Situ Transmission Electron Microscopy (TEM)