Context-Conditioned Disagreement: Which Expert Uncertainty Survives the Chart?

Medical AI models that learn from several experts' labels usually treat disagreement as a property of the image: some scans are ambiguous, so the model should say so. Clinicians, however, rarely read images without the patient's chart. A radiologist who sees a lab value or the patient's age may settle a case that looked ambiguous on pixels alone. The reading panels that produce multi-rater training labels are usually built retrospectively, and they are often shown only the image. If so, the "expert uncertainty" these models learn is the uncertainty of a reading condition that never happens in the clinic. This proposal separates ambiguity that clinical context removes from ambiguity that persists even with full context. The plan is to collect expert readings of the same cases with and without clinical context, train a model to predict the disagreement that remains given context, and test prospectively whether showing clinicians that residual disagreement, instead of a single probability, reduces harmful deference to wrong AI suggestions.

The core claim is concrete and falsifiable. The disagreement a model should report at deployment is the disagreement among experts who saw the same multimodal evidence the deployed clinician sees. Panels that read images alone produce systematically wrong uncertainty targets, and this is a form of retrospective data bias that lives in the labeling protocol rather than in patient selection. The testbed is prostate cancer detection on micro-ultrasound, where prostate-specific antigen (PSA, a blood marker), PSA density and age are routinely available. Systematic biopsy also gives a histology reference for every sampled region, whatever the readers or the model say.

What Exists and Where This Differs

Three lines of work model expert disagreement, and all of them condition only on the image. The Latent Doctor Model uses a conditional variational autoencoder, a generative model that samples a hidden "style" variable, to output the full distribution of pathologists' grades. It reports a KL divergence of 0.461 on Gleason2019 and a Spearman correlation of up to 0.728 with the entropy of 20 pathologists on ISUP grading. Multi-rater Prompting gives each rater a learnable prompt in a frozen segmentation network. Difficulty-aware Glaucoma Classification uses disagreement to flag hard cases. These papers motivate the proposal, because they show disagreement carries signal, and they supply the method, which we reuse. None of them asks what the raters were shown.

A second line of work fuses images with clinical context but treats labels as fixed. ProstNFound injects age, PSA and PSA density as prompts into a frozen MedSAM encoder. It reports a core-level AUROC of 78.3%, compared with 71.1% for TRUSFormer, and says the clinical prompts alone added over 7%. PECon aligns CT with health-record data, and the bone tumour fusion study finds through feature attribution that age is the strongest single input. That last result is direct evidence that context changes diagnoses, and so presumably changes which cases experts disagree on.

The closest bridging work is HAICOMM, which feeds human raters' calls into a T1+T2 MRI model and scores 80% accuracy against 70% for the human majority vote, judged against surgery on 30 retrospective cases. HAICOMM uses rater opinions as an input. We use the dependence of rater opinions on context as the object of study. On the deployment side, the prospective fundus trial shows that an image-only, deterministic assistant raised junior ophthalmologists' diagnostic consistency from 72.9% to 84.9%. The file notes that clinicians in such trials tend to defer to the AI even when their initial impression differed, and no trial has tested an assistant that communicates calibrated disagreement.

Core Claim

Let $p_{\text{img}}(y \mid x)$ be the distribution of expert calls $y$ for image $x$ when experts see the image alone. Let $p_{\text{ctx}}(y \mid x, c)$ be the same distribution when they also see clinical context $c$. We split total observed ambiguity into two parts:

$$H\big(p_{\text{img}}\big) = \underbrace{\big[H(p_{\text{img}}) - H(p_{\text{ctx}})\big]}_{\text{context-resolvable}} + \underbrace{H(p_{\text{ctx}})}_{\text{residual}}$$

Here $H$ is the entropy of the expert-call distribution. Strictly, the first term can be negative, because context can create disagreement, for example when a high PSA makes some readers call a benign-looking region suspicious. Those cases are part of what we want to find. The hypothesis is that only the residual term predicts where assisted clinicians make errors in deployment. A model trained on image-only panels will overstate ambiguity on cases that context resolves. It will understate ambiguity on cases that context makes contentious. As a result its uncertainty display will be miscalibrated in exactly the cases where calibration matters.

Research Program

The first component is a crossover reading study on a retrospective multi-center micro-ultrasound cohort with per-core histology. The cohort follows the five-center, leave-one-center-out design of ProstNFound. A panel of about eight readers of mixed seniority scores each case twice, once with images only and once with images plus age, PSA and PSA density. Order is randomized and the two sessions are separated by a washout of at least four weeks. Every case therefore gets two empirical rater distributions from the same people. We first measure the decomposition descriptively: how much disagreement context removes, how much it creates, and whether residual disagreement tracks histology errors better than image-only disagreement does.

The second component is a model. The architecture is deliberately unoriginal: the ProstNFound backbone with clinical prompts, plus a Latent-Doctor-style rater latent. The novelty is in the training targets and the evaluation. The main model is trained to match $p_{\text{ctx}}$. Its twin is identical but trained on $p_{\text{img}}$. A third head predicts biopsy histology. In cases where the reference standard is itself graded subjectively, we follow the LDM's ISUP setting and have a subset of cores regraded by several pathologists, so we can check that conclusions survive grading discordance in the reference standard.

The third component is a prospective, randomized reader study embedded in routine biopsy at participating centers. Consecutive patients are enrolled without quality filtering, except for an image-quality gate of the kind used in the fundus trial, and its rejection rate is reported. Each reader records an unassisted impression first. They then see one of three randomized displays: nothing, a single AI probability, or the AI probability plus the predicted residual expert disagreement. They then record a final call. Systematic cores are taken under standard protocol in all arms, so histology exists for every region and does not depend on the arm.

Baselines

The do-nothing reference is the reader's unassisted first impression in the prospective study and the unassisted panel reading in the retrospective study. Every assisted condition must improve on it in AUROC for clinically significant cancer and must not raise the rate at which readers abandon a correct impression.

The strongest existing system is a ProstNFound-style multimodal point predictor. It uses the MedSAM backbone, VICReg texture features from the raw radio-frequency signal, and prompts for age, PSA and PSA density. It is retrained on our folds with the same leave-one-center-out splits, the same compute, and a hyperparameter search budget equal to our model's. The reference figure is the reported core-level AUROC of 78.3% from ProstNFound. Because our cohort differs, the comparison that counts is our retrained replica. Our model must not lose more than a pre-registered one AUROC point on discrimination. Its claimed advantage lies elsewhere: lower calibration error against held-out residual disagreement, and better prospective reader outcomes.

The multi-rater baseline is the image-only Conditional Latent Doctor Model from the LDM paper, trained on the image-only panel. The ablation that isolates our key ingredient is the identical metadata-prompted model trained on $p_{\text{img}}$ instead of $p_{\text{ctx}}$. If the two twins match in KL divergence to held-out context-condition readings and in prospective error prediction, the labeling-condition claim fails. We also include a majority-vote multimodal model and a deep ensemble trained on histology. The ensemble supplies an outcome-based uncertainty competitor.

Why not just…?

Why not just add metadata as an input to an existing multi-rater model? That is our architecture, and we do not claim it as new. The question is what it is trained to reproduce. Adding context to a model whose targets came from image-only readers teaches it to predict, from the chart, how experts would disagree without the chart. The twin-target ablation tests whether this distinction matters. If it does not, the result is still useful: retrospective image-only panels would then be safe to reuse.

Why not just train a multimodal classifier on biopsy outcomes and show its predictive entropy? This is the real threat. Histology is complete in this setting, so outcome-based uncertainty is available and needs no expensive reading panels. It may flag the same cases. The two can diverge, however. Outcome entropy marks cases where biology is unpredictable. Residual disagreement marks cases where clinicians predictably split, and these may be the cases where assisted readers defer wrongly. The retrospective study measures which of the two better predicts reader errors. The prospective design could add a fourth arm showing outcome entropy if the retrospective result is close. If outcome entropy matches or beats residual disagreement, we will report that the reading panels are not worth their cost.

Why not just filter out discordant raters, or train on the majority vote with temperature scaling? Variability Matters found that training only on the top 50 to 75% most conforming of 120 pathologists beat training on all of them, at Fleiss' kappa 0.43. That result supports filtering when the goal is accuracy on dense detection. Our target is the disagreement itself, which filtering removes by design. We include conformity filtering as a discrimination baseline and expect it to be competitive on AUROC but unable to say which cases are contested.

Why not just validate retrospectively across centers? Leave-one-center-out validation tests for shift in the patient population. It cannot test how readers react to a display. The fundus trial's assistance effect, a gain from 72.9% to 84.9%, and the deference problem the file describes for such trials could only be observed prospectively. Retrospective validation also cannot show whether readers in live practice disagree the way the context panel did.

Decisive Checks

The first check is retrospective. On held-out centers, does the context-trained model match held-out context-condition readings better in KL divergence than its image-trained twin? Does its predicted residual entropy correlate more strongly with reader error against histology than both image-only disagreement and outcome-ensemble entropy, measured by Spearman correlation and by AUROC for flagging reader errors? The second check tests for drift: is disagreement among prospective readers, who have the chart, closer to the context-panel distribution than to the image-only panel? The primary prospective endpoint is the rate at which a correct unassisted impression is switched to agree with an incorrect AI suggestion. We compare the disagreement display against the point-probability display, require no loss in overall sensitivity for clinically significant cancer, and use a sample size powered from the retrospective error rates. A null result on the primary endpoint, with the decomposition still holding retrospectively, would mean that how disagreement is measured matters but showing it does not change clinician behavior. That result is publishable, and it would redirect the effort toward how disagreement is presented rather than how it is estimated.