Compartment-Decomposed Retinal Stroke Risk for Multi-Specialist Review

Deep learning models can now read a routine photograph of the back of the eye and estimate whether a person has silent strokes or will have a stroke. The retina is developmentally part of the brain, and its small vessels share genetic and physiological traits with cerebral vessels. These models still return one opaque number, and that number lands in front of several specialists who each need something different from it. A neurologist wants to know whether the risk comes from narrowed arterioles, the vessel pattern that tracks white-matter damage on brain MRI. An ophthalmologist wants to know whether it comes from a lesion or an imaging artifact. A primary care physician wants a calibrated risk to act on. Software engineering and collaborative virtual reality research has a well-tested answer to this kind of problem: keep one shared underlying model and give each role its own view of it. That answer only works if the shared model can actually be split into parts that match the roles' concerns.

We propose to build that split into the model rather than paint it on afterward. The retinal stroke-risk predictor will be written as a sum of contributions from separately segmented anatomical compartments: arterioles, venules, the non-vascular background tissue, and the optic disc. Role-specific views are then exact projections of the same sum, linked by shared image coordinates. In two sentences: role-tailored clinical views are only honest if the prediction itself breaks down along the lines each specialist reasons in, so we train a retinal stroke model whose risk adds up over vessel compartments. We then test whether views built from those true parts improve multi-specialist decisions more than the same views built from post-hoc explanations or from hand-measured vessel statistics.

Core Claim

The opportunity is not "dashboards for oculomics." Re-skinning a single black-box score into several templates gives each role a different presentation of the same uninterpretable number. That is the generic-persona failure in a new costume. The claim is narrower and testable. First, an additive compartment model can come close to the accuracy of a monolithic retinal foundation model for stroke and silent brain infarction. Second, its compartment contributions are faithful: deleting a compartment changes the prediction by the amount the decomposition says it should. Third, role views populated with these faithful contributions lead to better-calibrated reliance and higher cross-specialist agreement than views populated with post-hoc saliency on a black box.

The motivating evidence comes from both sides. On the clinical side, an optical coherence tomography angiography study of 246 older adults found that different retinal compartments track different cerebral injuries, though the correlations were modest and cross-sectional (Lower Retinal Arteriolar Density Is Associated With Higher Cerebral Small Vessel Disease Burden). Arteriolar density tracked periventricular white-matter lesions (r = −0.17) and basal ganglia perivascular spaces (r = −0.20), while venular density tracked deep white-matter lesions (r = −0.17). Meanwhile the strongest stroke system, DeepRETStroke (A deep learning system for detecting silent brain infarction and predicting stroke risk), processes whole-image patches with a large Vision Transformer and outputs one probability. It reports AUC 0.797 for silent brain infarction against 0.633 for clinical traits, and 0.901 for internal incident stroke.

On the collaboration side, three findings point the same way. A review of 105 software visualization papers traced industrial non-adoption to tools designed for an undifferentiated user (A Systematic Literature Review of Modern Software Visualization). A storyboard system showed that metadata "hotspots" anchored to a shared artifact let designers and developers each extract what they need while keeping traceability (Get Your Requirements Straight: Storyboarding Revisited). A co-located multi-view virtual reality study found that individualized views beat a single shared view on finish time, communication time and errors (Multi-view VR system for co-located multidisciplinary collaboration).

The Responsive Workbench work constrains our design (The two-user Responsive Workbench). It warns that specialized views stay coherent only when they are registered to a common coordinate space, so collaborators can point at the same thing. We take that lesson literally: every role view is indexed by the same compartment masks on the same image.

Research Program

The model has three parts.

First, a vessel segmenter labels each fundus image into compartments. We reuse the hierarchical vascular encoder HRVRL (An Efficient and Interpretable Foundation Model for Retinal Image Analysis in Disease Diagnosis), which learns artery–vein separation from 267 annotated images and runs on a single GPU. Here it supplies the method; we do not claim it.

Second, a shared image encoder produces features. We use RETFound (A foundation model for generalizable disease detection from retinal images) or HRVRL's ConvNeXt backbone. Features are pooled separately inside each compartment mask $m_c$.

Third, the risk is written as

$$\mathrm{logit}\, p(y=1 \mid x) = b + g(z) + \sum_{c \in \{\mathrm{art}, \mathrm{ven}, \mathrm{bg}, \mathrm{disc}\}} f_c\big(\mathrm{pool}(h(x \odot m_c))\big).$$

Here $x$ is the image, $h$ is the encoder, $\odot$ is pixelwise masking, $f_c$ is a small per-compartment head, $z$ holds clinical covariates (age, sex, blood pressure) with their own head $g$, $b$ is a bias term, and $y$ is the outcome (incident stroke, or MRI-confirmed silent infarction).

Masking the input rather than only the pooled features matters. A global-attention backbone would otherwise let arteriolar evidence leak into the "venular" term. We will measure this leakage directly rather than assume it away.

The background term is deliberate. Kim et al. found that retinal tissue with the vessels digitally removed still predicts age and sex (Kim et al.). An honest decomposition must therefore report how much risk lives outside the vessels instead of forcing it into vascular terms.

The views are deterministic projections of the decomposition.

The neurologist view shows the arteriolar and venular contributions next to the hand-measured vessel density and branching complexity of each compartment. This lets the neurologist check the learned term against the known morphometric correlates.

The ophthalmologist view shows the background and disc contributions, image-quality flags and lesion overlays. Its main question is whether risk is driven by pathology or artifact.

The primary care view shows the summed, calibrated absolute risk with a population-validity flag. The flag matters because performance drops across ethnic cohorts (Are Traditional Deep Learning Model Approaches as Effective as a Retinal-Specific Foundation Model).

Every number in every view links to the same masked image region. When one specialist selects a compartment, it is highlighted in all views. This is the shared anchor that the storyboard and Workbench work identify as necessary.

Baselines

The naive reference point is a clinical-traits-only model on the same covariates $z$. DeepRETStroke reports AUC 0.633 for this kind of model on silent brain infarction. Our model must clear it by a wide margin or retinal input is not earning its place. For the user study, the naive interface is the bare risk score.

The strongest existing predictor is a monolithic retinal foundation model fine-tuned end to end on the same outcome labels and splits. We will use RETFound fine-tuned for incident stroke on UK Biobank and MEH-AlzEye, with the same clinical covariates concatenated so that only the decomposition differs. DeepRETStroke reports internal incident-stroke AUC 0.901 and silent-infarction AUC 0.797, but on Chinese-centred cohorts whose data we cannot assume access to. We found no reported result on Lacuna for RETFound on incident stroke specifically; RETFound's file-reported systemic figure is heart failure AUROC 0.794 on fundus photographs. Comparisons will therefore be run head to head on our own splits, with identical tuning budgets (same number of hyperparameter trials and epochs) and the same encoder initialization. "Beating" is not the target here. Success means staying within 0.02 AUROC of the monolithic model, with overlapping bootstrap intervals, while gaining verified faithfulness. A larger accuracy loss would undercut the case for using the decomposition clinically.

The interpretable reference baseline is a logistic regression on classical morphometrics. Its inputs are arteriolar and venular density, fractal branching dimension, and caliber, each computed from the same HRVRL segmentation, plus $z$. This tests whether learned compartment heads add anything beyond quantities a clinician already understands.

The key ablation isolates whether the decomposition must be built into the model. It keeps the identical interface and compartment masks, but fills the per-compartment numbers by splitting a post-hoc attribution on the monolithic model. We will run both Grad-CAM and Integrated Gradients, summed within each mask. If post-hoc splits are as faithful and as useful to clinicians, the intrinsic decomposition is unnecessary.

Why not just…?

Why not just run Grad-CAM on the black box and mask it by vessel type? This is the most serious alternative, and it is exactly our ablation. Beaudouin et al. argue that generic post-hoc maps do not adapt to who is reading them and can give false reassurance (Flexible and Context-Specific AI Explainability). That is a conceptual argument, not a measurement. Our test is faithfulness. We will inpaint each compartment and compare the actual change in predicted risk to the change each explanation implies. If masked attributions match the true changes as well as the additive terms do, we will drop the intrinsic model and keep only the interface.

Why not just report vessel density and branching numbers next to the black-box score? The morphometric baseline tests this directly. The known correlations are weak (|r| ≤ 0.20), which suggests hand-crafted measures capture only part of the signal. If the morphometric logistic model matches the learned compartment model on discrimination, the learned heads add nothing. In that case the proposal reduces to role views over classical measurements, which is still a useful but more modest result.

Why not just write role-specific text summaries of one score with a language model, as in conversational eye-care triage? Meta-EyeFM routes single-user queries to task models (An integrated language-vision foundation model for conversational diagnostics and triaging in primary eye care). Rewording a single number per audience cannot tell a neurologist whether the arterioles drove it. The user study includes a "role-templated black-box" condition to measure whether presentation alone delivers the benefit.

Proposed Experiments

The modelling experiments use UK Biobank fundus photographs linked to incident stroke and MEH-AlzEye linked to hospital stroke outcomes. Splits are held out by site, and transfer is evaluated from SEED-like Asian to European cohorts to expose the generalization drop. We report three kinds of results:

  1. Discrimination (AUROC with bootstrap intervals) and calibration (expected calibration error).
  2. Faithfulness: correlation between predicted and observed risk change under compartment inpainting.
  3. Leakage: how much the venular head's output moves when only the arterioles are perturbed.

The first decisive check is whether additive compartment heads stay within 0.02 AUROC of the monolithic model while achieving clearly higher deletion faithfulness than masked Grad-CAM. If they lose more accuracy than that, the decomposition is too lossy to deploy. If they fail to be more faithful, it is unnecessary.

The second check is mechanistic. In any cohort with paired retinal imaging and brain MRI that we can access, we ask whether the arteriolar contribution correlates more strongly with periventricular white-matter lesions, and the venular contribution with deep white-matter lesions, than either correlates with the opposite lesion type. This reproduces the dissociation in the OCTA study. A decomposition that fails this check is not giving neurologists what their view claims to show.

The third check is a within-subjects case review with mixed teams of neurologists, ophthalmologists and primary care physicians. Teams review cases with MRI-confirmed reference labels, with known model errors seeded in. Four interface conditions are compared: score only, score plus Grad-CAM, role-templated black box, and decomposed role views.

Outcomes are appropriate reliance (accepting correct predictions and overriding wrong ones), team decision accuracy, cross-specialist agreement, and time to decision. Following the multi-view virtual reality study, we also measure communication time and how often discussion refers to a shared compartment anchor. The proposal succeeds only if decomposed views improve reliance on erroneous cases over the role-templated black box. Improving over score-only is not enough, because that would show the benefit comes from presentation rather than from the faithful parts.