NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Coincidence Testing for Early Liver Cancer Recurrence

After surgery removes a liver cancer (hepatocellular carcinoma, HCC), the tumor often comes back. In the months before recurrence is confirmed, a patient usually shows two weak hints that are each too faint to act on. One is a small, ambiguous spot on a follow-up scan. The other is a slight excess of tumor-like DNA fragments in the blood. Today these hints are judged separately, and each is dismissed as noise. Physicists searching for gravitational waves and high-energy neutrinos face the same situation and have a principled fix. When two independent detectors each register a below-threshold event, they ask how likely it is that both appeared by chance at the same time, in the same place, and with compatible energies. Veske et al. showed that one such candidate rose from a 7.7% to an 86–97% posterior probability of being real once a coincident neutrino was taken into account.

We propose to apply this coincidence logic to post-surgical HCC surveillance. The central object is a likelihood ratio that does more than multiply the two weak signals. Under the "no cancer" hypothesis, a benign nodule and the background DNA shed by a cirrhotic liver are unrelated. Under the "recurrence" hypothesis, the amount of tumor DNA in blood should match the size of the imaged nodule, after correcting for how well the patient's liver and kidneys clear DNA from the blood. Requiring this match, which plays the role that energy and arrival-time consistency play in astrophysics, is what we claim adds information beyond simple fusion. The second new ingredient is a background model for blood DNA that depends on liver function.

Core Claim

Let $s$ be the blood measurement: the number of sequencing reads called tumor-derived, out of $n$ reads. Let $v$ be the volume of the most suspicious nodule on the scan, and $c$ a clearance covariate. For $c$ we use the albumin-bilirubin (ALBI) score, a standard composite of liver function, together with kidney function. We compute

$$\frac{p_{\rm rec}}{1-p_{\rm rec}} = \frac{\pi}{1-\pi}\cdot\frac{\int P(s \mid n, v, \lambda, c)\,P(v \mid R)\,P(\lambda)\,d\lambda}{P(s \mid n, c, B)\,P(v \mid B)},$$

where the symbols are defined as follows. The quantity $\pi$ is the prior recurrence risk at that visit, taken from a clinical nomogram. $R$ and $B$ denote recurrence and background. The parameter $\lambda$ is an unknown shedding rate per unit tumor volume, averaged over a prior. In the numerator, $s$ depends on $v$ through the shedding model. In the denominator, $s$ and $v$ are independent, and the blood background $P(s \mid n, c, B)$ depends on clearance.

If the numerator ignored $v$, the expression would collapse to naive Bayes: the product of two separate likelihood ratios. The difference between our model and that product is the "coincidence factor." We expect it to help most in a specific regime: a weak signal in each modality, plus a blood excess whose size is consistent with the nodule. This is the regime where surveillance currently stalls.

Relation to Prior Work

Two strands of prior work supply the components, and neither addresses the joint problem.

On the blood side, NEEM-seq with DeepTrace changes the sequencing library preparation so that it no longer adds artificial unmethylated bases to fragment ends. It then classifies each cell-free DNA read with a transformer model. On a 130-person cross-sectional cohort it reached 93.6% sensitivity and 98.5% specificity at 1.6X depth, with about 89.5% sensitivity in early-stage disease. We reuse its per-read scores as our blood detector. Unlike that work, we model longitudinal post-surgical recurrence rather than one-time diagnosis.

ctDNAmer fits a three-component mixture calibrated on healthy-donor plasma to separate tumor fraction from technical background. In colorectal cancer it detected 77% of relapses, with a median lead of 8.1 months over imaging. We borrow its strategy of calibrating background against control samples, but our controls are cirrhotic. Healthy donors would understate the background in HCC, where diseased liver tissue continuously sheds DNA and clearance is impaired (renal and liver function in ctDNA testing). Neither method uses imaging.

On the imaging side, the LiTS benchmark shows that automated liver tumor detection reached only 0.554 lesion-wise recall, with many false positives. This motivates the proposal: imaging alone produces exactly the ambiguous candidates our method is meant to resolve.

The post-hepatectomy nomograms combine static MRI and pathology features and reach a recurrence-free survival C-index (a ranking-accuracy measure for survival models) of 0.701 on their test set, against 0.678 for standard Barcelona Clinic Liver Cancer staging on overall survival. We use such a nomogram only as the prior $\pi$. It has no blood or longitudinal input.

The physics paper also constrains our design. Veske et al. note that their posteriors depend strongly on assumed emission parameters. Our analogue is the shedding prior $P(\lambda)$, so we average over $\lambda$ rather than fixing it, and we report how sensitive the results are to that choice.

Research Program

The work has three stages.

Detector calibration. We train a nodule detector on LiTS and record its score distribution and volume estimates for true lesions and false positives. Next, we build the clearance-conditioned background $P(s \mid n, c, B)$ by running DeepTrace on plasma from cirrhotic and hepatitis patients without cancer, stratified by ALBI grade. We then construct in-silico dilution series by mixing tumor-derived reads into these backgrounds at known fractions. These series let us measure blood-side sensitivity near the detection limit.

Shedding model. We fit a simple shedding model linking tumor volume to expected tumor fraction under clearance $c$. The data come from pre-operative HCC patients who have both plasma and a measured tumor diameter. We fit a hierarchical log-linear model and carry its spread forward as the prior over $\lambda$.

Retrospective application. We apply the method to a post-hepatectomy cohort with banked plasma drawn at routine surveillance visits and paired MRI or CT. The endpoint is recurrence confirmed by pathology or by definitive follow-up imaging.

The file contains no public dataset with paired serial blood samples and imaging after resection. This cohort must therefore be assembled from institutional biobanks, and it is the project's main practical risk.

Baselines

Naive reference points. The first reference point is current practice: a recurrence call from the radiologist or the imaging detector alone at its standard threshold. Its lead time is defined as zero. A second reference is the rule "act if either signal is positive," which catches more recurrences at the cost of specificity.

Blood alone. This baseline is DeepTrace scores thresholded per visit. It gets the same plasma, the same reads, and the same background controls as our method. For context, its published cross-sectional sensitivity is 93.6%, but no reported result was found on Lacuna for DeepTrace in post-surgical recurrence monitoring.

Clinical nomogram. The RSF–Cox nomogram from the 494-patient study is refit on our training split. Its reported test C-index for 2-year recurrence-free survival is 0.701. Beating it means a higher C-index on the same held-out patients.

Learned late fusion. The strongest competitor is a gradient-boosted classifier or Cox model trained directly on the nodule score, nodule volume, blood tumor-read fraction, ALBI, and nomogram risk. It gets the same splits and the same hyperparameter-search budget as our model's few free parameters receive. Because it sees volume and blood signal together, it can in principle learn the coincidence structure. No reported result was found on Lacuna for any combined imaging-plus-blood model of HCC recurrence.

Ablations. Two ablations isolate the new ingredients. The first removes the coupling between $s$ and $v$, which yields naive Bayes. The second replaces the clearance-conditioned background with a healthy-donor background, as in ctDNAmer.

What counts as winning. Our method beats the competitors if, at a matched specificity of 95% per visit, it achieves higher sensitivity and a longer median lead time over the imaging-only call, together with better calibration as measured by expected calibration error.

Why not just…?

Why not just train a joint classifier on both signals? This is the real threat. With enough labeled recurrences, a flexible model could learn that blood signal and volume should co-vary. Our bet is that post-hepatectomy cohorts contain only dozens to low hundreds of recurrences. In that range, a model whose coincidence structure and background are fixed in advance from control data should be better calibrated and should transfer better across liver-disease causes; the nomogram study's 85.6% hepatitis B population already illustrates how cohorts differ. We settle this with learning curves: we subsample training recurrences and test on held-out cohorts that differ in cause. If learned fusion matches us at every training size, we will report that the gain is limited to calibration and interpretability.

Why not just sequence deeper or sample blood more often? Deeper sequencing removes technical errors but not the real background DNA shed by a cirrhotic liver. It also gives up the low-cost 1.6X regime that makes DeepTrace practical for surveillance. The clearance ablation tests directly whether background shift, rather than read count, drives the false positives in high-ALBI patients.

Why not just lower the imaging threshold or scan more often? LiTS shows that false positives already limit automated detection at current thresholds (LiTS). Lowering the threshold trades sensitivity for many more benign callbacks. The "either positive" baseline and the imaging score sweep measure this trade-off on our cohort.

Decisive Checks

The method's value rests on three results.

First, the coincidence factor must matter. The full model should beat the naive-Bayes ablation at matched specificity, and the gain should concentrate in visits where both signals are below threshold. If the gain is spread evenly across visits, the volume–shedding coupling is not doing the work.

Second, the clearance-conditioned background should cut false-positive blood calls among Child-Pugh B and high-ALBI patients compared with the healthy-donor background, without lowering sensitivity.

Third, the posterior should be well calibrated across the range of shedding priors. If conclusions flip with reasonable changes to $P(\lambda)$, the method inherits the model-dependence weakness Veske et al. reported and is not ready for clinical use.

A positive outcome on all three, together with a lead time measured in months over imaging-only calls, would make a prospective study worthwhile.