Closing the Loop Across the Slice Gap: Back-Projection with a Learned Slice Profile for Anisotropic CT and MRI

Most clinical CT and MRI scans are sharp within each slice (under a millimetre) but coarse between slices (three to five millimetres). Models that fill in the missing slices, or that segment the scan one slice at a time, lose the third dimension. Organs come out stair-stepped, vessels break apart, and structures seen on one slice vanish on the next. The best current slice-filling method in our reading, Slice Imputation, makes one forward guess and never checks it. It warps neighbouring slices to synthesize the in-between ones, but nothing tests whether the result, re-acquired by the scanner, would reproduce the slices that were actually measured. Iterative back-projection supplies exactly that check. It is an old super-resolution idea: degrade your high-resolution guess with the known acquisition model, compare it with the real low-resolution data, and push the error back into the guess, over several rounds.

We propose to run back-projection along the slice axis, with one change that matters. A thick slice is not a thin slice that happens to have been kept. It is an average of the tissue across the slab, weighted by the scanner's slice profile, and that profile differs across scanners and protocols. Our network therefore jointly estimates the slice profile for each scan and corrects its thin-slice reconstruction inside a learned feedback loop. The claim we test is narrow. Closed-loop consistency with a correctly estimated slice profile reduces through-plane hallucination and segmentation fragmentation more than three alternatives: open-loop warping, consistency imposed only as a training loss, and post-hoc correction. We also check whether any of this beats simply training a native 3D segmenter on the anisotropic data.

Core Claim

Let $y$ be the unknown thin-slice volume and $x_k$ the $k$-th acquired thick slice centred at depth $z_k$. The acquisition is modelled as $x_k = \sum_j h(z_j - z_k)\, y_j$, where $h$ is a discretized slice profile with a few parameters (for example a mixture of a boxcar and a Gaussian with width and gap terms). Write this operator as $D_h$. The reconstruction is refined by

$$y^{(t+1)} = y^{(t)} + U_\theta\big(x - D_{\hat h}(y^{(t)}),\; y^{(t)}\big),$$

where $U_\theta$ is a small learned network. It lifts the slice-space residual back to the thin grid, conditioned on the current estimate, and its weights are shared across iterations. $\hat h$ is the per-scan estimate of the profile.

This differs from deep back-projection networks in two ways. Deep Back-Projection Networks alternate learned up- and down-projection units in the 2D image plane, and their down-projection is learned rather than physical. Here the down-projection is the physical slice-integration operator, which is cheap because it acts along one axis only. That sidesteps the memory cost that makes full 3D back-projection blocks with 8×8 or 12×12 kernels impractical.

The profile $\hat h$ is estimated from the scan itself. Within-slice image statistics are high resolution, so we fit $\hat h$ such that applying $D_{\hat h}$ along an in-plane axis reproduces the frequency falloff observed along $z$. This rests on a local isotropy assumption that we test explicitly. It also addresses the known failure of back-projection under a wrong degradation model, which is the second open problem in the file: a mismatched $D$ makes the loop amplify error rather than remove it.

Relation to Prior Work

Two papers motivate the gap.

Slice Imputation shows that filling anisotropic gaps helps segmentation. It reports Brain Tumor Dice of 87.00% against 82.91% for a U-Net and 68.69% for linear interpolation. However, it uses open-loop warping regularized only by a through-plane smoothness loss. Smoothness rewards plausible-looking continuity, not fidelity to what was measured.

Roth et al. document the fragmentation caused by slice-wise prediction and patch it with a fixed 3D Gaussian, which raises pancreas Dice from 56% to 68%. That result shows how much through-plane coherence is worth. It also sets the bar any learned method must clear over a free heuristic.

Three papers supply the mechanism, each in a form that falls short for tomographic volumes.

Neural Volume Super-Resolution imposes a downsampling-inconsistency loss on rendered radiance-field views. The consistency acts only at training time, through ray marching, on optical scenes.

CDDN with two-step data consistency inserts hard measurement replacement between network stages in MRI k-space. The authors state that it is limited to 2D slices. Hard replacement is also the wrong operator for thick slices, because no thin slice equals a measured thick slice.

Recurrent Back-Projection iterates residuals across video frames. It relies on optical flow, which models motion, not slab integration.

Two lines of work constrain the design.

Tri-Plane Mamba shows that full 3D attention costs about 18.86 GFlops per block on a 96³ volume. This is why we keep the feedback loop one-dimensional along $z$ and push context modelling into a light network.

UNETR and the nnU-Net results reported in the Medical Segmentation Decathlon (0.94 Dice on spleen and liver) show that native 3D segmenters are already strong on organs. Any gain from reconstruction must therefore show up on thin, elongated, or small structures, not on large organs.

Research Program

We build three components:

  1. Slice-profile estimator. A per-scan routine with three to five parameters, fit by matching the in-plane and through-plane spectra.
  2. Iterative reconstructor. A 2.5D network: in-plane features come from a shared 2D encoder, and the residual lifting $U_\theta$ uses 1D-in-$z$ plus local 3D convolutions. It is unrolled for $T$ iterations, with $T$ swept from 1 to 6.
  3. Downstream segmenter. A standard nnU-Net-style 3D U-Net trained on the reconstructed volumes.

Training uses near-isotropic volumes, from which thick-slice inputs are synthesized under randomized slice profiles, thicknesses (3–5 mm), and gaps. This gives ground-truth thin slices. To test the profile estimator honestly, the profiles used at test time are drawn from a family held out from training, including asymmetric and side-lobed shapes.

We analyse three things. The first is how the residual $\|x - D_{\hat h}(y^{(t)})\|$ evolves over iterations. The second is whether reconstruction error falls monotonically with $T$ or diverges under profile mismatch. The third is where in the volume the loop changes the estimate; we expect boundaries crossing the slice gap obliquely.

Baselines

The naive references are two. The first is linear interpolation along $z$ followed by the same segmenter. The second, more important, is a 3D U-Net with nnU-Net-style anisotropic configuration trained directly on the thick-slice data with no reconstruction. The second is the "do nothing to the data" reference a clinician's pipeline would actually use. On organs it should be expected to sit near the 0.94 Dice that the Medical Segmentation Decathlon reports for spleen and liver.

The strongest existing method is Slice Imputation. It is the only method in our reading that targets the same anisotropic gap for segmentation, and it reports 87.00% Dice on the Brain Tumor task. We reimplement it on our splits, using the same thick-slice simulation and the same downstream segmenter. Its hyperparameter search budget is the same as ours, and we train both to matched wall-clock time on the same GPUs. Beating it means a statistically significant Dice gain on brain tumor and on the thin or tubular BTCV structures (pancreas, adrenals, portal and splenic veins, esophagus). It also means lower held-out-slice reconstruction error and lower through-plane surface roughness. A gain on large organs alone would not count.

The ablations isolate the key ingredient:

  • Loss-only. The same reconstructor with $T=1$, trained with an added $\|x - D_h(y)\|$ penalty, which is the Neural Volume Super-Resolution recipe moved to voxels.
  • Post-hoc classical correction. Classical iterative back-projection applied after Slice Imputation, the step Timofte et al. found reliably helpful in 2D.
  • Hard replacement. Data consistency by thin-slice replacement, the CDDN-style operator applied naively.
  • Fixed profile. The full loop with a fixed boxcar profile instead of the estimated $\hat h$.
  • Oracle profile. The full loop given the true profile, which bounds what better profile estimation could buy.

All ablations share architecture, data, and budget.

Why not just…?

Why not just train a native 3D segmenter on the anisotropic scans? This is the most serious threat. nnU-Net already adapts its kernels and resampling to anisotropy, and if it matches us on Dice, the segmentation case for reconstruction collapses. We do not argue around this; we measure it. If the anisotropic 3D U-Net is within noise of our pipeline on BTCV thin structures and brain tumor, we will report the contribution as a reconstruction result only. That result would cover faithful thin-slice volumes for reading and measurement, scored by held-out-slice error and robustness to profile shift.

Why not just add a consistency loss to Slice Imputation? Training-time consistency, as in Neural Volume Super-Resolution, may capture most of the benefit at no inference cost. The loss-only ablation settles this directly. The loop should win mainly when the test-time slice profile differs from training, because only the loop can use the scan's own residual at inference. If loss-only matches the loop even under held-out profiles, we will recommend it instead.

Why not just apply classical back-projection or Gaussian smoothing after the fact? Post-hoc correction worked in 2D (Timofte et al.), and smoothing gave Roth et al. a 12-point Dice gain. But a fixed back-projection kernel spreads error isotropically. Zhang et al. found that this causes ringing, and smoothing cannot restore structure that was never reconstructed. Both appear as baselines, so the size of the remaining gap will be measured rather than assumed.

Proposed Experiments

The data are the Medical Segmentation Decathlon Brain Tumor, Liver, and Prostate tasks (matching Slice Imputation's evaluation) and BTCV's 13 abdominal organs, with thick slices simulated from the thinnest available acquisitions. We report four groups of metrics:

  • Reconstruction: PSNR and SSIM on withheld thin slices.
  • Segmentation: Dice and 95th-percentile surface distance, computed on the true thin grid.
  • Volumetric context loss: a through-plane surface-roughness score on sagittal and coronal sections, plus the number of spurious connected components per structure, the fragmentation Roth et al. describe.
  • Profile recovery: the error of $\hat h$ against the true profile.

There are three decisive checks. The first is a profile-shift sweep: train on one profile family and test on held-out shapes and thicknesses. The loop with estimated $\hat h$ should degrade far less than Slice Imputation and the fixed-profile ablation, and the fixed-profile loop should show error growing with iterations. That would confirm that the operator, not merely the iteration, is what matters. The second is an iteration sweep, $T$ from 1 to 6, at matched parameters. Fragmentation and roughness should fall with $T$ before saturating; if they are flat, the feedback adds nothing. The third is the comparison with the anisotropic 3D U-Net on thin and tubular structures. This tells us whether the work is a segmentation method or a reconstruction method, and the note's conclusions will follow whichever way it comes out.