NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Censoring-Aware Multiple Imputation for Cooperative Spectrum Sensing

Cognitive radios are allowed to transmit in licensed TV and radio bands only where the licensed "primary" user is absent. To decide where that is, many cheap sensors cooperate. Each sensor reports received power on a few channels, and a central node fills in the rest of the node-by-channel table by exploiting its low-rank structure, which comes from the small number of active transmitters. Existing systems fill in that table once and then act on it as if the guesses were measurements. This proposal replaces the single fill-in with multiple imputation, meaning many plausible completed tables drawn from a posterior, so that the vacancy decision becomes a statement about probability ("this channel is free here with 99% confidence").

The part that makes this more than a transplant is where the gaps in a sensing table come from. There are two sources. Some cells are missing because the scheduler told that sensor not to measure, which is missing completely at random and known by design. Other cells are "missing" because the power fell below the receiver's sensitivity floor. Those cells are not missing at all. They are censored observations carrying the information "the value is below $\tau$". Current spectrum-completion pipelines treat both kinds identically, either dropping the floor readings or clamping them to the floor. The floor readings are also exactly the cells that decide hidden-terminal risk. We propose a low-rank copula imputer that models the two mechanisms separately, and we evaluate it on the quantity a regulator cares about: how often a channel declared vacant was actually occupied, measured against how much usable spectrum is recovered.

Core Claim

A multiple-imputation fusion center that treats scheduled gaps as ignorable and below-sensitivity readings as censored will produce vacancy decisions whose violation rate tracks a chosen nominal level $\alpha$. It will do so while recovering more spectrum than deterministic completion with a fixed safety margin. The advantage should appear specifically in the censored stratum, where both deterministic completion and residual-calibrated intervals are miscalibrated, because the ground truth needed to calibrate them is systematically unobserved there.

The decision rule is simple. Let $\hat P^{(k)}_{ij}$ be the received power at location or node $i$ on channel $j$ in the $k$-th of $K$ imputed tables, and let $\gamma$ be the protection threshold. Channel $j$ is declared usable at $i$ when

$$\frac{1}{K}\sum_{k=1}^{K} \mathbf{1}\left[\hat P^{(k)}_{ij} > \gamma\right] \le \alpha .$$

Here $\alpha$ is the tolerated probability of harmful occupancy. Every design choice below is judged by whether this estimated probability is calibrated.

Prior Work and Its Roles

Three lines of spectrum-completion work motivate the gap. Collaborative spectrum sensing from sparse observations using matrix completion for cognitive radio networks completes a 20-node by 100-channel sensing matrix with a fixed-point nuclear-norm solver and then runs joint-sparsity detection. It reports a probability of detection of 95.55% at 16.8% sampling with three primary users. Its missingness is purely designed random undersampling, and its output is a single matrix. Compressive Multispectral Spectrum Sensing for Spectrum Cartography reconstructs space-by-frequency power cubes by compressive recovery, with PSNR above 24 dB at 50% of samples. Deep Spectrum Cartography: Completing Radio Map Tensors Using Learned Neural Models disaggregates radio maps into per-emitter components and completes them with learned priors, reaching squared reconstruction error of about 0.08 at 5% coverage. All three return point estimates and never distinguish a scheduled gap from a reading below the noise floor. We keep their low-rank and superposition insight and change what is output and how the gaps are modeled.

Two papers supply the method. gcimpute: A Package for Missing Data Imputation implements a low-rank Gaussian copula. This model estimates each variable's distribution nonparametrically, links variables through a low-rank latent Gaussian, supports truncated variables, and supports streaming updates; it reports 94.3% empirical coverage for nominal 95% intervals on UCI White Wine. That combination of low rank, explicit censoring, and multiple draws is the core we adapt, with channels as variables and nodes and time slots as rows. Inference and Uncertainty Quantification for Noisy Matrix Completion de-biases nuclear-norm estimators to get per-entry Gaussian confidence intervals with 94–95% coverage on 1,400-station temperature data. This is the strongest existing uncertainty method for low-rank completion. It assumes uniformly random missingness and sub-Gaussian noise, so it is both our main competitor and the natural test of whether censoring matters.

Two works constrain the design. Spectrum sensing by cognitive radios at very low SNR fixes the operating regime: sensitivity near −114 dBm and sensing windows of tens of milliseconds. Any imputer must therefore run online within that budget. Spectrum Sensing With Non-Gaussian Noise Over Multi-Path Fading Channels Towards Smart Cities With IoT documents heavy-tailed impulsive noise. A copula's nonparametric marginals absorb skew and monotone distortions, but not additive spikes that break the latent dependence. We treat this as a stated risk to test, not a solved problem.

Research Program

The model treats each time slot's node-by-channel power readings as a row vector. Channels, and bands where the data is multi-band, are columns. Each entry falls into one of three states: observed, scheduled-missing, or censored below the sensor's known floor $\tau_i$. The copula imputer fits channel marginals from observed and censored entries jointly. Censored entries contribute an interval $(-\infty, \tau_i]$ in latent space rather than being dropped. The latent covariance is low-rank, with rank tied to the number of active emitters. Posterior draws then sample scheduled-missing cells from the conditional Gaussian and censored cells from the conditional Gaussian truncated to the interval. For spatial radio maps, rows are grid locations and a small spatial-neighbor feature block is appended so the copula can use proximity as well as cross-band correlation.

We will build three things. The first is the censoring-aware imputer in batch and online form, using the streaming mini-batch EM of gcimpute. The second is the probabilistic vacancy rule above, plus a Rubin-pooled variant for continuous statistics such as estimated interference margin. The third is a latency profile showing whether K draws fit in a 24–48 ms sensing window. The analysis question is when censoring handling matters. Our hypothesis is that dropping censored readings inflates the estimated marginal mean and weakens the estimated dependence, which wastes spectrum holes. Clamping them to the floor should instead deflate variance near shadow boundaries, which produces missed detections. The experiments decide which effect dominates at which censoring level.

Baselines

The naive reference is complete-case cooperative fusion: combine only the sensors that reported, using majority or weighted combining as in Spectrum Sensing: To Cooperate or Not to Cooperate?. Censored readings are counted as "no signal". This is what a deployed fusion center does without any completion. Beating it means lower violation rate at equal or better spectrum recovery.

The deterministic standard is the matrix completion of Meng et al. followed by a fixed safety margin on the threshold. We sweep the margin over a grid (1–6 dB) and report the entire violation-versus-utilization curve, so the baseline is never judged at an unlucky margin. On their synthetic setup it must first reproduce roughly their reported 95.55% detection at 16.8% sampling with three users. Beating it means that at every matched violation rate, our rule recovers more truly vacant cells. A single well-chosen margin being competitive would count against us.

The strongest uncertainty competitor is the de-biased matrix completion of Chen et al. We threshold its per-entry Gaussian intervals at the same $\alpha$. It receives the same observed entries and the same rank-selection procedure, done by cross-validation on held-out observed cells. We report it in two versions, censored-as-missing and censored-clamped, because it has no native censoring. It is also given a tuning budget equal to ours. Beating it means lower calibration error of the violation rate in the censored stratum, without losing utilization in the scheduled-missing stratum. If it matches us everywhere, censoring handling is not worth the complexity, and we will say so.

The key ablation is our own imputer with the censoring model switched off, treating censored cells as ordinary missing values. This isolates the proposal's specific ingredient from the generic benefit of copula multiple imputation. A second ablation sets $K=1$ (a single stochastic draw) to separate the effect of the draws from the effect of the model.

Why not just…?

Why not just use deterministic completion with a conservative margin? A uniform margin cannot follow the fact that uncertainty is large near shadow edges and small in densely observed bands. The file's summary of Conformal Prediction with Missing Values makes the same point, that missingness patterns induce non-uniform variance. The margin sweep in our baselines tests this directly. If the best fixed margin's curve lies on ours, the alternative wins.

Why not just calibrate point imputations with conformal prediction? This is a real threat, because conformal calibration gives distribution-free coverage cheaply. Its weakness here is specific: calibration residuals can only be computed on cells where the truth was recorded, and censored cells are by construction the ones whose truth is never recorded above the floor. The calibration set is therefore selected on the outcome. We include split-conformal calibration of the deterministic completer as an extra baseline, using held-out observed cells. The stratified coverage analysis will show whether it undercovers in the censored stratum. If it does not, we will recommend it over our method.

Why not just use Kriging, which already gives a prediction variance? On the measured urban dataset of Measured spectrum environment map dataset with multi-radiation sources in urban scenarios, the file reports only that inverse distance weighting beat Kriging in accuracy and speed; no numerical error is given. Separately, Gao et al. report spatial interpolation reaching a decimation rate of 4 versus 16 for their compressive model. Kriging also ignores cross-band correlation from shared emitters. We still run Kriging with its variance under the same rule, since its interval is the most familiar alternative in cartography.

Why not just use standard chained-equation imputation (MICE)? It has no censoring model and no low-rank constraint, and the gcimpute comparison on MovieLens reports the low-rank copula as 34% faster with MAE 0.583 against 0.616. That result is from recommender data, not radio, so we run MICE on the smaller synthetic setting as a sanity check rather than assume it loses.

Proposed Experiments

The first testbed reproduces the synthetic benchmark of Meng et al.: 20 nodes, 100 channels, one to three primary users, sampling rates of 8–20%. We add a censoring floor $\tau$ swept so that 0–40% of cells fall below it, and we add impulsive noise in a secondary arm. The second testbed is the measured urban dataset of Zou et al.: 1 m grid, three bands at 30 MHz, 115 MHz and 2 GHz, three sources. We impose artificial censoring by thresholding measured RSS and scheduled gaps by random masking, so censored cells have known ground truth. No reported RMSE for IDW or Kriging on this dataset was found on Lacuna, so we establish those numbers ourselves. The USRP cubes of Gao et al. and the indoor dataset used by Guo et al. serve as secondary tests if accessible. For those the reference points are PSNR above 24 dB and squared reconstruction error of about 0.08, respectively.

The primary metrics are three. The first is the realized violation rate against nominal $\alpha$ at 1%, 5% and 10%. The second is the fraction of truly vacant cells recovered at matched violation rate. The third is 95% interval coverage, reported separately for scheduled-missing and censored cells. Secondary metrics are RMSE of imputed power and per-slot latency against a 24 ms budget, using online updates.

The decisive check is the censored-stratum coverage and violation calibration. We expect the de-biased completion of Chen et al., conformal calibration, and our no-censoring ablation to stay near 95% coverage on scheduled-missing cells, since that is the regime where the first reports 94–95%. We expect them to drift away from nominal on censored cells as the censoring fraction grows, while the full model stays near nominal. If that divergence does not appear, the central claim fails. The second check is whether the calibrated rule's utilization curve strictly dominates the best fixed margin. The third is whether the online imputer meets the sensing deadline at K around 20. If it cannot, we test whether a smaller K preserves calibration of the tail probability.