Body-Size-Aware Miss-Rate Guarantees for ICU Hypoglycemia Alerts

In intensive care, patients with higher body mass index (BMI) develop dangerously low blood sugar less often than lean patients. This is one face of the "obesity paradox," the finding that extra body mass seems protective during acute illness. An alert system that learns from the whole ICU population will therefore see few hypoglycemia events in heavier patients. When one does occur, the alert may stay quiet, because the model has learned that such patients rarely crash. We propose to measure that failure directly and to fix it with a calibration step that is simple to state. The step guarantees that, within each body-size and diabetes group, the alert misses no more than a fixed fraction of true hypoglycemia episodes. It also reports what that guarantee costs in extra alarms for each group.

The opportunity matters for two reasons. First, the epidemiology is already established: across 259,177 ICU patients in four databases, The obesity paradox and hypoglycemia in critically ill patients reports hypoglycemia odds ratios of 0.72 for overweight, 0.65 for obese and 1.6 for underweight patients, relative to normal weight. The same paper reports that the protection largely disappears in patients with diabetes. That study calls for "precision glycemic control," but it builds no alerting system. Second, the tools for per-group error control already exist in conformal prediction, a family of methods that turn any model's scores into decisions with distribution-free error guarantees. They have been used on skin types, as in Fair Conformal Predictors for Applications in Medical Imaging, but never on metabolic-reserve groups in a bedside alert.

Core Claim

Our claim is that marginal error control, meaning a guarantee averaged over all ICU patients, will hide a concentrated miss rate in exactly the group clinicians least expect to crash. We predict this group is obese patients without diabetes, while underweight patients may be over-alerted. We also claim that controlling the false-negative rate separately for each BMI-by-diabetes group closes that gap at a measurable and reportable alarm cost. Finally, we claim that the guarantee survives transfer between hospitals only if the group-wise calibration is redone on a small local sample.

The grouping needs no causal reading. Association of body mass index, metabolic health status and clinical outcomes in acute myocardial infarction patients shows that much of the apparent obese survival advantage after heart attack is confounded by age. That critique constrains how we talk about BMI, not what we do with it. A miss-rate guarantee only requires that error rates differ across groups, whatever the reason.

Research Program

The prediction task follows Plečko et al.: at each glucose measurement, predict whether a glucose value below the hypoglycemia cutoff occurs within the next six hours. We build the cohorts with the harmonized pipeline from Yet Another ICU Benchmark across MIMIC-III, MIMIC-IV, eICU, HiRID and AUMCdb. That paper found that preprocessing and cohort choices move results more than model architecture does, so fixing the pipeline is the fairest starting point. The scoring model is a gradient-boosted tree model (LightGBM) and a recurrent network (GRU), both reported in that benchmark. Inputs are vitals, labs, insulin, dextrose, steroids and nutrition, plus BMI and diabetes status.

Groups are formed by crossing four BMI categories with diabetes status. We add one more group for patients missing height or weight. These patients are common in EHR data and plausibly sicker, and silently dropping them would bias the audit.

The calibration step is conformal false-negative-rate control, a special case of the conformal risk control used in Conformal Risk Control for Semantic Uncertainty Quantification in Computed Tomography. For each group $g$, take the $n_g$ calibration episodes in which hypoglycemia occurred. Choose the alert threshold $t_g$ as the largest value for which at most $\lfloor \alpha (n_g+1) \rfloor - 1$ of those episodes score below it. This yields

$$P(\text{score} < t_g \mid \text{hypoglycemia}, g) \le \alpha,$$

where $\alpha$ is the tolerated miss rate. The bound comes from exchangeability of the group's positive episodes. Two choices handle practical limits. Repeated windows within one patient are not exchangeable, so calibration samples one episode per patient. When $n_g$ is too small for the requested $\alpha$, the threshold falls to "always alert" for that group. We treat this as an honest output: it tells the hospital that it lacks data to promise anything better there.

The cross-site component addresses what Conformal Prediction and Human Decision Making calls the "Twoishness" problem: guarantees hold only if the calibration data match the deployment data. We train and calibrate at one site, test at another, and then test recalibration that uses only the first few hundred local patients.

The alert itself never abstains. On the Limits of Selective AI Prediction found that a model saying "I defer to you" raised missed diagnoses by 18% and missed treatments by 35% among 259 clinicians, because silence read as reassurance. Our system therefore expresses uncertainty only by moving the threshold, never by going quiet. A small secondary vignette study will test a one-sentence plain-language explanation attached to alerts in low-base-rate groups, compared with a bare alert. This design follows the finding in Natural Language Generation enhances human decision-making with uncertain information that text beat graphics-only uncertainty displays by 24.8% in decision performance. That study was a weather game, not a clinic, so we treat its result only as motivation.

Baselines

The do-nothing reference is current practice: no predictive alert, with hypoglycemia detected only when a measured glucose crosses the cutoff. Every predictive method is scored by how many events it flags ahead of that point.

The naive model baseline is a Plečko-style logistic regression with BMI categories and the same adjustment variables, thresholded once for the whole population. It is the most transparent competitor and the one clinicians already trust.

The strongest existing method is the YAIB LightGBM model with marginal conformal miss-rate control at the same $\alpha$, the population-level conformal design used for sepsis in Artificial intelligence sepsis prediction algorithm learns to say "I don't know". We found no reported result on Lacuna for ICU hypoglycemia prediction on YAIB or these databases. The nearest reported figures belong to other tasks: YAIB reports mortality AUROC of 0.84 to 0.87, and COMPOSER reports sepsis AUC of 0.925 to 0.953 in the ICU. We will therefore establish the baseline numbers ourselves.

Fairness controls apply to every arm. All arms share the same cohorts, features, trained scoring model, calibration patients and $\alpha$, so they differ only in how thresholds are set.

Two ablations isolate the key ingredient. One groups by BMI alone, dropping diabetes. The other uses random groups of identical sizes, which tests whether the metabolic grouping, rather than group-wise thresholding per se, carries the effect.

Beating the strongest baseline means two things. First, the worst-group miss rate stays at or below $\alpha$ across 200 random calibration and test splits where the marginal method exceeds it. Second, the added alarms per patient-day in each group stay within a pre-registered tolerance. If that tolerance is exceeded, we report the result as a cost, not a win.

Why not just…?

Why not just include BMI as a model feature? The model already sees BMI. Adding a feature improves average discrimination but promises nothing about miss rates within a group, especially a group with few events. The experiment tests this directly: if group miss rates under the marginal threshold are already at or below $\alpha$ once BMI is a feature, our central hypothesis is false, and we will report it as such.

Why not just tune a separate threshold per group on a validation set? This is the real threat, since it is nearly the same computation without the finite-sample correction. The two should agree in large groups. They should diverge in small ones, such as underweight patients with diabetes or patients missing BMI, where empirical tuning will exceed $\alpha$ in a visible fraction of resamples. If repeated-split violation rates turn out indistinguishable, the contribution reduces to the subgroup audit and the cross-site findings, and we will say so.

Why not just use Mondrian conformal prediction on BMI categories? Mondrian conformal prediction calibrates separately within each predefined category. It is the simplest version of what we propose, and it is the BMI-only ablation. Plečko et al.'s finding that diabetes erases the BMI effect predicts that BMI-only grouping leaves the diabetic subgroups miscalibrated. That ablation decides whether the interaction is worth its smaller groups.

Why not just use better body-composition measures instead of BMI? DXA-based ratios outperform BMI for long-term mortality in Association of body fat distribution with all-cause and cardiovascular mortality, with an AUC of 0.785. Chest X-ray models also capture hidden adiposity, as shown in Opportunistic detection of type 2 diabetes using deep learning from frontal chest radiographs. However, neither DXA nor linked X-ray adiposity estimates are routinely available in these ICU databases. The guarantee is agnostic to how groups are defined, so a richer measure can replace BMI whenever it becomes available.

Why not just abstain when unsure? Jabbour et al.'s clinician study shows that abstention increases missed diagnoses. Abstention would also fall hardest on the low-base-rate group where we expect misses. We exclude it by design.

Proposed Experiments

The first decisive check is the audit. On each of the five databases, we measure the per-group miss rate of the strongest baseline at $\alpha$ of 0.05, 0.1 and 0.2. This tests whether the obese non-diabetic group is undercovered, as the paradox predicts, and whether underweight patients absorb excess alarms.

The second check applies group-wise control and reports worst-group miss rate, alarms per patient-day per group, and median warning lead time before the measured event.

The third check covers transfer. We calibrate on eICU or MIMIC-IV, test on HiRID and AUMCdb, and compare no recalibration, full recalibration, and recalibration on 100, 300 and 1,000 local patients. The outcome is how much local data restores the guarantee in each group.

The vignette study is the fourth and least certain check. A small clinician panel views matched cases with and without the explanatory sentence, and the outcome is the rate at which alerts in low-base-rate groups are dismissed.

The proposal fails cleanly if the audit finds no subgroup undercoverage, or if closing the gap costs more alarms than any unit would tolerate. Either result is still informative to anyone deploying population-calibrated alerts.