Screening systems in dermatology and ophthalmology increasingly rely on one useful fact: experts disagree more about the boundaries of dangerous lesions. A model trained to predict how much several doctors would disagree on an image gets a free diagnostic signal. That signal can also tell the system when to hand a case back to a human. This proposal argues that the signal has a hidden flaw. Experts and models also disagree more when an image is simply blurrier or captured at lower resolution. A hospital with a different camera therefore shifts the predicted disagreement for reasons unrelated to disease. If a screening threshold was set at one site, its promised miss rate quietly breaks at the next.
We propose to measure this confound, separate it out, and build a "rule-out" screener whose miss-rate guarantee holds across sites. A rule-out screener is one where a confident negative is used to send the patient home. Its output has three options rather than two: discharge, refer, or re-image. The core move is to treat effective resolution as an explicit, label-free variable. Effective resolution here means how many pixels actually span the lesion or optic disc, together with a measured sharpness score. The screener conditions both its disagreement estimate and its discharge threshold on that variable. Disagreement caused by blur then triggers re-imaging instead of referral, and calibration transfers to new sites through a measurable variable instead of fresh labels.
Core Claim
Predicted inter-observer disagreement mixes two things: genuine biological border ambiguity and acquisition-induced blur. Inter-observer disagreement is the spread between segmentations drawn by different experts on the same image. Mixing its two causes is a major, previously unmeasured reason that sensitivity-prioritized operating points fail under single-center bias.
We make two testable predictions. First, conditioned on effective resolution, the distribution of malignancy scores among true positives is approximately invariant across sources. Second, under that invariance, a discharge threshold calibrated separately within each resolution stratum keeps its target miss rate on held-out sites. A single global threshold, and a threshold built on resolution-blind disagreement, will not.
If the first prediction fails, it fails informatively. It would show that institutional shift in these screening settings is not mainly a scale effect. That is itself useful to know before anyone engineers scale invariance into screening models.
What Prior Work Leaves Open
Two papers motivate the diagnostic value of disagreement. What Can We Learn from Inter-Annotator Variability in Skin Lesion Segmentation? shows that malignant lesions get lower expert agreement (mean Dice 0.753 versus 0.791 for benign). It predicts agreement directly from the image with mean absolute error of about 0.108, and adding agreement prediction as a second task improves balanced diagnostic accuracy by 4.2%. Calibrate the inter-observer segmentation uncertainty via diagnosis-first principle replaces majority-vote ground truth with diagnosis-weighted "expertness" maps, gaining up to 2.73% AUC on REFUGE-2.
Both works operate at a fixed image scale and optimize average accuracy or AUC. Neither asks whether the agreement signal moves when acquisition changes, and neither targets a bounded miss rate. We reuse their idea of an agreement-prediction head. What we add is conditioning on resolution and a calibrated discharge policy.
Three papers constrain the design. Preanalytic variable effects on segmentation and quantification machine learning algorithms for amyloid-β analyses on digitized human brain slides shows that downsampling 40X scans to 20X does not reproduce native 20X behavior (p = 0.0013). It also shows that even a same-vendor scanner change shifts segmentation (p = 0.0005). Together these mean we cannot synthesize resolution strata by resizing. We must use native resolution heterogeneity that already exists across data sources, and use synthetic degradation only as a diagnostic.
Mind the Gap: Continuous Magnification Sampling for Pathology Foundation Models shows that training on a few discrete scales leaves "sawtooth" accuracy dips at intermediate scales. Continuous sampling recovers 3.6 to 3.9 points of balanced accuracy there. We adopt continuous scale sampling in training, but that paper addresses classification accuracy with consensus labels, not disagreement or miss-rate guarantees.
IMA++: ISIC Archive Multi-Annotator Dermoscopic Skin Lesion Segmentation Dataset documents a heavy disagreement tail: 236 images with mean pairwise Dice below 0.5 and 23 with zero overlap. That tail is exactly where blur and biology need separating.
On the screening side, the Direction 2 Summary reports a 0% clinically important miss rate in large-scale diabetic retinopathy screening through operating-point tuning, but within its development distribution. Brain Metastasis Segmentation Network Trained with Robustness to Annotations with Multiple False Negatives shows that annotators' missed lesions can be counteracted with a loss that distrusts negative labels. That loss recovers sensitivity from 10% to 97% of baseline under 50% simulated omissions, but only within one center and one acquisition protocol. Neither addresses what happens to the threshold at another site.
Research Program
The work has three parts.
Measure the confound in humans. Using IMA++ we compute, for every multi-annotated image, its effective resolution. This is the number of pixels spanning the lesion's bounding region, plus a label-free sharpness statistic such as high-frequency energy inside the lesion mask. We then regress observed human pairwise Dice on effective resolution and diagnosis jointly. IMA++ records annotator identity and annotation tool, which lets us control for both. The question is whether resolution explains agreement beyond diagnosis.
Measure the confound in models. We train the multi-task agreement model of the skin-lesion study and ask whether its predicted agreement falls faster with resolution than human agreement does. A faster fall would mean the model over-reads blur as ambiguity.
Build the conditioned screener. The screener has a shared encoder trained with continuous scale sampling, and two heads. A diagnostic head outputs a malignancy score $s(x)$. An agreement head outputs predicted agreement $a(x, r)$, where $r$ is the effective-resolution descriptor and is given to the head as an explicit input. Because the head sees natively varied data, it learns how agreement changes with $r$. We read off a resolution-adjusted agreement $\tilde a(x) = a(x, r_{\text{ref}})$ at a fixed reference resolution and feed it to the diagnostic head. The gap $a(x,r) - \tilde a(x)$ is the blur-attributed part of the disagreement. When that gap is large, the case is routed to "re-image" rather than "refer."
Calibrate the discharge rule within resolution strata. For a target miss rate $\alpha$ (for example 2% of positives discharged), we split training-source data into resolution strata $R_k$. Within each stratum we choose the threshold
$$\tau_k = \text{the } \lceil \alpha (n_k+1) \rceil\text{-th smallest score } s(x_i) \text{ among the } n_k \text{ calibration positives in } R_k,$$
and discharge a new case in stratum $k$ only if $s(x) < \tau_k$ and no re-image flag is raised. This is split conformal calibration applied to the positive class: if new-site positives in $R_k$ are exchangeable with calibration positives in $R_k$, the stratum miss rate is at most $\alpha$.
The exchangeability assumption is the core claim, and it is checked directly on held-out sources. The design also carries a practical constraint. Each stratum needs on the order of $1/\alpha$ positives or more. So the number of strata is set by available positives, and this tradeoff is reported rather than hidden.
Secondary domain: fundus images. We replicate the pipeline on REFUGE, whose images come from two camera models (Zeiss Visucam 500 and Canon CR-2). Glaucoma screening is a classic sensitivity-first task, and optic cup boundaries are notoriously ambiguous; the REFUGE winning team for cup segmentation reached Dice 0.8837. We use the multi-rater REFUGE-2 labels as used in the diagnosis-first study, with effective resolution defined as optic disc diameter in pixels.
Baselines
The naive reference is a single-label segmentation-plus-classification model trained on majority-vote masks. All images are resized to a common grid with standard scale jitter, and one global discharge threshold is tuned on the pooled training sources to hit $\alpha$. This is what most deployed pipelines do. The proposal must beat it on held-out-source miss rate while matching or exceeding its discharge fraction, meaning the share of negatives safely sent home. No reported result was found on Lacuna for held-out-source miss rate at a fixed discharge target on IMA++ or REFUGE. We therefore establish this number ourselves.
The strongest existing method for using disagreement is the multi-task agreement model from What Can We Learn from Inter-Annotator Variability in Skin Lesion Segmentation?, reported at a 4.2% balanced-accuracy improvement across PH2, derm7pt, ISIC 2018, ISIC 2019 and IMA++. It is the closest competitor because it already turns disagreement into diagnostic signal. We reimplement it on the same encoder, data splits and hyperparameter search budget as our model, then give it the same global conformal threshold. Beating it means a lower worst-source miss rate at equal discharge fraction, not merely higher pooled balanced accuracy.
On fundus images, the strongest baseline is DiFF from Calibrate the inter-observer segmentation uncertainty via diagnosis-first principle, reported at up to 2.73% AUC gain over prior multi-rater learning on REFUGE-2. It is run under the same protocol, including camera-held-out evaluation. As context, the REFUGE challenge reports a top glaucoma classification AUC of 0.9885 and human expert sensitivity of 85% at about 91% specificity (REFUGE Challenge). We report where our discharge policy sits relative to that human operating point.
The strongest shift-aware calibration competitor is covariate-shift-weighted conformal calibration. It reweights calibration positives by a density-ratio classifier trained to distinguish source from unlabeled target images, using the same unlabeled target pool our method may see.
Two ablations isolate the key ingredient. The first stratifies calibration by random strata of identical sizes instead of resolution. The second removes $r$ as an input to the agreement head and drops the re-image route. If either ablation matches the full method, resolution conditioning is not doing the work.
Why not just…?
Why not just resample everything to a common grid and augment heavily? The amyloid study shows resampled and native-resolution images produce significantly different predictions. Mind the Gap shows that discrete multi-scale training leaves dips at intermediate scales. Both findings suggest resampling cannot remove the confound, because humans themselves were looking at the blurrier native image when they disagreed. Resampling does not change the labels. Still, this baseline is run in full. If its held-out-source miss rate matches ours, the claim is falsified.
Why not just recalibrate the threshold at each new site? With labeled positives from the new site, per-site calibration is the gold standard. But certifying a 2% miss rate needs on the order of fifty or more confirmed positives, which a new clinic rarely has at launch. The realistic competitor is weighted conformal calibration with unlabeled target data, and it is a genuine threat. If density-ratio weights already capture the resolution shift, it will match us. Our bet is that a one- or two-dimensional physical variable gives tighter, more stable thresholds than a learned weight over full images, especially for small target sites. The worst-source and small-site comparison in the experiments settles this directly. If weighted conformal wins, the contribution narrows to the diagnostic finding about blur and disagreement, and we will say so.
Why not just drop disagreement and lower the threshold of a plain classifier? That removes the confound by removing the signal. The 4.2% balanced-accuracy gain from agreement prediction and the strong correlation the Latent Doctor Model reports between model entropy and expert-panel disagreement (Spearman up to 0.728) suggest the signal is worth keeping. The naive baseline tests this. If it matches our discharge fraction at equal miss rate, disagreement modeling adds nothing for rule-out screening, and that would itself be a result.
Decisive Experiments
All skin-lesion experiments use leave-one-source-out evaluation over PH2, derm7pt, ISIC 2018/2019 and IMA++. Where IMA++ metadata permits, contributing groups are also held out. Fundus experiments hold out each REFUGE camera in turn. The primary metric is the miss rate on the held-out source at a fixed $\alpha$, reported both as worst-source and as within-stratum values. Secondary metrics are the fraction of negatives discharged, the fraction routed to re-imaging, and the per-stratum Spearman correlation between predicted and observed human agreement on IMA++ multi-annotated images.
The first check is the human regression. If effective resolution does not predict IMA++ agreement after controlling for diagnosis, annotator and tool, the premise is wrong and the program stops at a negative report.
The second check is invariance. We test whether the distribution of $s(x)$ among positives, within a resolution stratum, differs across sources, using two-sample tests with source as the grouping. Compared against the same test without stratification, this tells us whether stratification is what restores exchangeability.
The third check is the guarantee. The full method should hold the held-out-source miss rate within sampling error of $\alpha$, while the global-threshold baselines exceed it on at least the sources whose resolution distribution differs most from the training sources.
The fourth check is a synthetic stress test. We downsample high-resolution IMA++ images, knowing this is not native acquisition, and ask whether the blur-attributed component $a(x,r) - \tilde a(x)$ grows while $\tilde a(x)$ stays flat. A $\tilde a$ that tracks downsampling would mean the decomposition failed.
The fifth check concerns the cost of re-imaging. The re-image route must catch a disproportionate share of the positives that the global-threshold baseline wrongly discharges, and it must flag few enough cases overall to stay clinically usable. We report both numbers side by side, because a re-image flag that fires on most low-resolution images merely hides the miss-rate problem rather than solving it.
References
- What Can We Learn from Inter-Annotator Variability in Skin Lesion Segmentation?
- Calibrate the Inter-Observer Segmentation Uncertainty via Diagnosis-First Principle
- Preanalytic variable effects on segmentation and quantification machine learning algorithms for amyloid-β analyses on digitized human brain slides
- Mind the Gap: Continuous Magnification Sampling for Pathology Foundation Models
- IMA++: ISIC Archive Multi-Annotator Dermoscopic Skin Lesion Segmentation Dataset
- A clinical data-driven machine learning approach for predicting the effectiveness of piperacillin-tazobactam in treating lower respiratory tract infections
- Brain Metastasis Segmentation Network Trained with Robustness to Annotations with Multiple False Negatives
- REFUGE Challenge: A Unified Framework for Evaluating Automated Methods for Glaucoma Assessment from Fundus Photographs
- The Latent Doctor Model for Modeling Inter-Observer Variability