Auditing Fairness Fixes Across the Whole Age Range

When a clinical prediction model works worse for one age group, researchers usually apply a fix, such as reweighting, debiasing, or recalibration. They then declare the fix "harmless" if performance did not drop in a couple of coarse age bins. This proposal argues that such a check is too weak. Whether a fix is harmless is a claim about a whole curve: how much the fix changes clinically relevant errors at every age. Two bins can average over a narrow age window where the fix makes things worse.

We propose an audit procedure that estimates this curve directly. It compares the fixed model against an explicitly named reference model on the same patients, and it reports a confidence band that holds over the entire age range at once. We will test, on public voice and dermoscopy benchmarks, whether published "age-harmless" fixes stay harmless when examined this way.

The motivation comes from two literatures that rarely meet. Risk-governance work has found that the harms caused by safety interventions themselves, called "mitigation risk", are almost never assessed. Towards Concrete and Connected AI Risk Assessment (C2AIRA) maps 16 concrete AI risk frameworks and finds this concept essentially unaddressed. Clinical cohort research keeps finding that pooling across ages hides effects that run in opposite directions. In a naturalistic study of antipsychotics in young people at clinical high risk for psychosis, medicated adolescents converted to psychosis significantly more often than unmedicated adolescents (p < 0.001), while medicated adults trended toward less conversion (p = 0.088). The same masking can happen to a machine-learning fix, and nobody currently measures it.

Core Claim

The closest existing work is Beyond Fairness: Age-Harmless Parkinson's Detection via Voice. It applies a fix to a voice-based Parkinson's detector: it masks the spectrogram regions an auxiliary age classifier relies on, and it ensembles several models. The paper reports that the fix avoids the "fairness tax", meaning the usual pattern in which adversarial debiasing helps younger patients by hurting older ones.

The evidence for that claim is two numbers on a split at age 55. With a ResNet50 backbone, young-cohort area under the precision-recall curve (AUPRC) rose from 0.6517 to 0.7488. Elderly-cohort AUPRC moved from 0.9739 to 0.9810.

Our claim is that this kind of evidence cannot establish harmlessness, for three reasons:

  • An elderly bin that runs from 56 to 90 can improve on average while a sub-window, for example the oldest decile, gets worse.
  • AUPRC measures ranking. A clinic acts on a single decision threshold, and that threshold moves when the model changes.
  • "Harmless" depends on what the fix is compared against.

That last point is the lesson of Marginal Risk Relative to What?. It shows that judging each new system only against its immediate predecessor lets small increments of harm add up without any single step triggering concern. If several fixes are stacked and each is checked only against the previous one, the cumulative change for a given age range is never examined.

What would be new is the object being tested and the test itself. We define the age-indexed marginal harm of a fix as

$$\Delta(a) = \mathbb{E}\big[\,L(f_{\text{fix}}(X), Y) - L(f_{\text{ref}}(X), Y)\;\big|\;A = a\,\big],$$

where the symbols are:

  • $X$ is a patient's input, such as a voice recording or a lesion image.
  • $Y$ is the diagnosis.
  • $A$ is age.
  • $f_{\text{fix}}$ and $f_{\text{ref}}$ are the fixed model and a named reference model.
  • $L$ is a decision-level loss computed at the operating threshold the clinic would actually use. Examples are the indicator of a false positive among true negatives, or of a missed case among true positives.

The fix is declared harmful at tolerance $\delta$ if the data reject

$$H_0:\ \sup_a \Delta(a) \le \delta,$$

that is, if some age window is credibly worse off by more than the tolerance.

Research Program

Estimating the curve. We estimate $\Delta(a)$ by local-linear regression of each patient's paired loss difference on age. Pairing is essential here. Both models are scored on the same held-out patients, so variation between patients cancels out of the difference.

Confidence band. The simultaneous band comes from a multiplier bootstrap that resamples whole participants, not individual recordings. This matters on the voice data: in the mPower study, many participants contribute repeated recordings, and treating those recordings as independent would make bands far too narrow.

Smoothing choice. The bandwidth, which sets how wide an age window each estimate averages over, is chosen by cross-validation on a held-out split that is never used for testing. We will report results over a range of bandwidths so readers can see whether conclusions depend on that choice.

Thresholds. Following On the Role of Calibration in Benchmarking Algorithmic Fairness for Skin Cancer Detection, each model gets its own threshold, set to reach 95% pooled sensitivity. This is the setting in which that paper found specificity of 71% on the ISIC 2020 data and as low as 40% on the prospective PROVE-AI cohort. A fix that changes the score distribution moves this threshold, and the false-positive burden shifts across ages as a result. We also run a calibration version of the audit, in which $L$ is the age-local calibration error.

Choice of reference. Every audit is run against two references:

  • the unfixed model, which is the "relative to the predecessor" comparison;
  • a fixed simple reference, either a plain cross-entropy model or the original pre-fix model held constant across a chain of fixes.

This second reference is how the "relative to what?" question becomes something we can measure.

Fixes to audit.

  • The masking-plus-ensemble method from the Parkinson's paper, reimplemented.
  • Adversarial debiasing, the method that paper reports imposes a fairness tax.
  • Per-age-bin temperature scaling, a simple recalibration that rescales each age bin's predicted probabilities separately.
  • Ensembling alone, with no masking.

Limitations. We will use chronological age only, because neither benchmark records biological maturity. Measures of biological maturation, such as the peak-height-velocity staging used by Antonijević et al., would be preferable but are unavailable. We also note that mPower diagnoses are self-reported, so label noise may itself vary with age.

Baselines

Naive reference: pooled change only. The "do nothing" audit reports the change in pooled AUPRC or pooled specificity at 95% sensitivity and calls the fix harmless if neither drops. This is the standard practice the calibration paper criticizes. Its models reach AUROC (area under the ROC curve, a ranking measure) of about 0.94–0.95 while still failing calibration. It runs on the same held-out patients as our audit. Beating it means detecting harm in age windows where the pooled change is null or positive.

Strongest existing audit: two-bin reporting. This is the evaluation used in the Parkinson's paper. AUPRC is reported separately for ages ≤55 and >55, and the fix counts as harmless if neither bin worsens. The reported numbers are young-cohort AUPRC 0.6517 → 0.7488, elderly 0.9739 → 0.9810, and the gap between groups narrowing from 0.3222 to 0.2322 on ResNet50 (0.3001 to 0.2327 on DenseNet161).

This is the strongest competitor because it is the published evidence for the exact claim we are questioning. We first reproduce these figures on the same mPower voice subset (10,569 Parkinson's recordings and 22,901 healthy-control recordings) with the same backbones. Then we apply both audits to the identical model outputs, so the two audits differ only in how they read those outputs. Beating it means either of two outcomes:

  • finding a statistically supported harmful window that the two-bin reading misses;
  • if no such window exists, certifying harmlessness with a band narrow enough to be informative.

Existing calibration test: score-based CUSUM. The calibration paper uses a score-based cumulative-sum (CUSUM) test to check whether a model's probabilities are calibrated across subgroups. It rejected perfect calibration for every model at p < 0.001 and identified age as the main driver of miscalibration. That test asks whether one model is miscalibrated, not whether a fix changed calibration. We will run it on each model before and after each fix, alongside our paired calibration audit.

Finer bins with Bonferroni correction. Fixed age bins (deciles or 5-year bins), each tested separately with Bonferroni correction, form a second baseline. This is the simplest way to go beyond two bins. We found no reported result on Lacuna for finer-than-binary age audits of a clinical fix, so we have no published number to compare against.

Ablation isolating the key ingredient. Our audit run with participant-level pairing, but with intervals computed separately at each age point instead of a simultaneous band, isolates the contribution of simultaneous inference. Running it without pairing (comparing the two models' age curves estimated independently) isolates the contribution of pairing.

Why not just…?

Why not just report finer age bins? This is a real threat. With enough data, deciles plus Bonferroni correction might detect most harms our method detects. Its expected weaknesses are low power in sparse bins, which matters because the Parkinson's paper reports a Parkinson's-to-control ratio of only 0.0795 among younger speakers, and sensitivity to where bin edges fall when the harm sits across a boundary. These are hypotheses, not established facts. The semi-synthetic experiment below compares detection power and false-alarm rate directly. If binning matches the smooth audit, we will say so and recommend binning as the simpler tool.

Why not just use the CUSUM calibration test? That test, from the calibration paper, judges a single model against perfect calibration. All four fixes may start from a miscalibrated model, so "both models fail" does not tell us whether the fix made a given age range worse. We test the paired difference instead. We also measure decision-level errors at the deployed threshold, which a calibration test does not cover.

Why not just fix the problem with per-age recalibration and skip auditing? Per-age temperature scaling is a plausible remedy for the age-driven miscalibration the calibration paper reports. It is itself a fix, though. It rescales each bin's probabilities, which reorders patients across bins, and that can shift who falls above a pooled 95%-sensitivity threshold. So we audit it rather than assume it is safe. If it comes out harmless everywhere, that is a useful positive finding.

Why not just use adversarial debiasing? The Parkinson's paper already reports that adversarial debiasing improves younger patients by degrading older ones. We include it as a positive control, a case where the audit should flag harm.

Proposed Experiments

Experiment 1: power and error control on semi-synthetic data. On held-out mPower voice predictions and ISIC 2020 dermoscopy predictions, we start from a real model. We create a "fixed" model by perturbing its scores so that false positives rise by a controlled amount inside a single age window. We vary the window's width (3 to 15 years), its location (including straddling age 55), and the size of the effect.

We then measure how often each audit detects the planted harm (power) and how often it raises an alarm when no harm was planted (false-alarm rate). The false-alarm runs are paired with perturbations that leave every age window unaffected.

This is the decisive check for whether the method is worth having. The expected results are:

  • The two-bin audit should miss narrow windows inside a bin.
  • Our audit should keep its nominal false-alarm rate. If it does not, the participant-level bootstrap is wrong.
  • Finer binning will either keep up with our audit or fall behind for narrow and straddling windows. Its result determines whether the extra machinery is warranted.

Experiment 2: auditing real fixes. We apply all four audits to the four fixes on mPower and on ISIC 2020, against both references. PROVE-AI is included only if access to its 603 prospective images can be obtained. Its small size will limit power, so it serves as an external check rather than a primary test.

Adversarial debiasing serves as the positive control and should show a harm curve over the older ages. The central question is whether the masking-plus-ensemble fix shows any credible harmful window at the 95%-sensitivity threshold. Comparing it with ensembling alone tells us whether the harmlessness is due to the masking or merely to ensembling.

Experiment 3: compounding across a chain of fixes. We stack fixes in sequence: masking, then ensembling, then per-bin recalibration. Each step is audited against its predecessor, and the final model is audited against the fixed original reference. This tests the compounding concern from the baseline paper in a clinical setting: whether harms that are individually under tolerance add up to a credible harm for some age range.

Two outcomes would each settle the core claim. Finding a harmful age window in a published "harmless" fix would show that the two-bin evidence was insufficient. A clean certificate with tight bands everywhere would mean that fix earns the label "harmless" on firmer grounds than it previously had.