WISDM

21 papers · 30 extracted observations · human activity recognition · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Reported absolute scores on this metric; fine-grained training or inference settings can differ.

98.098.599.099.420242025MHNN (table row labeled “Ours”): 99.33 (2024)CMD-HAR: 98.14 (2025)MSTI-AD: 98.84 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 7 of 7 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026TypiCore (ER) proposedACC (final average accuracy)51.73split: test · class-incremental · replay=ER · backbone=1D-CNNTypiCore: A Hybrid Active Query Strategy for Class-Incremental Learning on Time Series
Source quote
L501: ACC\uparrow │ 46.41 │ 36.02 │ 42.66 │ 41.13 │ 40.90 │ 50.69 │ 51.73
2025CMD-HAR proposedAccuracy98.14%split-ratio=7:2:1CMD-HAR: Cross-Modal Disentanglement for Wearable Human Activity Recognition
Source quote
L247: It is noteworthy that the G-mean of CMD-HAR has improved by more than 0.2 across all datasets involving complex activities (OPPORTUNITY, PAMAP2, UniMiB-SHAR, USC-HAD), significantly outperforming other models. This indicates that CMD-HAR holds a substantial advantage in recognizing activity categories that are challenging for other models to identify, particularly complex activities. At the same time, CMD-HAR has also achieved outstanding accuracy levels of 98.14% and 96.53% on simpler activity datasets, such as WISDM and UCI-HAR, respectively. These results highlight the strong performance of our model on both complex and simple datasets, further demonstrating its effectiveness in addressing the challenges of multimodal complex activity recognition.
2025MSTI-AD proposedAccuracy98.84%Related-work comparison on WISDM; the paper states MSTI-AD's accuracy exceeds the highe…Process Optimization and Deployment for Sensor-Based Human Activity Recognition Based on Deep Learning
Source quote
L264: MSTI-AD │ 73.05 │ 72.80 │ 69.29 │ 68.92 │ 98.84 │ 98.79
2025TransPL (Ours; n_c=8, n_f=64) proposedAcc.64.0unsupervised-domain-adaptation · n_c=8 · n_f=64TransPL: VQ-Code Transition Matrices for Pseudo-Labeling of Time Series Unsupervised Domain Adaptation
Source quote
L547: Ours │ 84.9 │ 66.0 │ 63.9 │ 66.7 │ 48.5 │ 61.8 │ 88.5 │ 74.4 │ 54.5 │ 30.4 │ 64.0
2025MSAP + DRSN-M(DM) proposedAccuracy98.24Ablation-table configuration; the table reports Accuracy. No split or averaging conditi…Redundant feature screening method for human activity recognition based on attention purification mechanism
Source quote
L178: DRSN-M(DM) │ 98.24 │ 97.09 │ 98.14 │ 87.55 │ 82.17 │ 87.60
2024MHNN (table row labeled “Ours”) proposedAccuracy99.33%setting=L3_NoACDisentangling Imperfect: A Wavelet-Infused Multilevel Heterogeneous Network for Human Activity Recognition in Flawed Wearable Sensor Data
Source quote
L304: Ours │ 99.33 │ 98.97 │ 99.24 │ 99.10
2021DTS (Disentangle Time-Series) proposedTarget classification accuracy82.9domain-adaptation · transfer=user 4 to user 15Learning Disentangled Representations for Time Series
Source quote
L366: WISDM 4 → 15 │ 78.2 │ 69.2 │ 82.7 │ 81.4 │ 82.9 │ 100.0