WFLW · Landmark Detection
32 papers · 47 extracted observations · facial landmark detection · Markdown · CSV · JSON API
Tasks on WFLWAll tasks (32)Facial Landmark Detection (15)Face Alignment (7)Facial Landmark Localization (7)Landmark Detection (2)Keypoint Localization (1)
TaskFacial Landmark Detection (22)Facial Landmark Localization (12)Face Alignment (9)Landmark Detection (3)Keypoint Localization (1)
Metricnme (25)error rate (10)nme inter ocular full (3)fr (2)nme ic inter ocular (2)psnr (1)nme inter ocular (1)
Showing 1 of 1 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | HybridMatch baseline | NME | 4.73% | Landmark Detection · split: test · semi-supervised · labeled-data=20% | Rethinking Self-training for Semi-supervised Landmark Detection: A Selection-free ApproachSource quoteL319: In addition to the existing semi-supervised landmark detection models~\cite{HMT18,DoY19,BjC20,JLS21,KLK23}, we also compare with semi-supervised pose estimation methods~\cite{RDG18,XWZ21} and generic self-training methods~\cite{Lee13,BTQ21,SBL20,CJW22}. For selection-based methods, we select their optimal thresholds based on the performance on 300W with 5% labeled data, which can be found in Fig.~\ref{fig:selection_thresh}. Following~\cite{KLK23}, we also equip our model with HRNet~\cite{WSC19} for better performance. Tab.~\ref{tab:results_semi} shows the results on 300W, WFLW, and AFLW with different labeled ratios. We can see that STLD obtains the best results on most of the entries. Specifically, STLD-HM-R18 and STLD-TF-R18 both outperform their ResNet-18 counterparts on almost all the entries, demonstrating the effectiveness of the proposed method. When a heavier backbone such as HRNet is equipped, the performance of STLD is further boosted. For example, STLD-HM-HRNet achieves 3.73, 3.40, and 3.32 of NME (%) on 300W for 1.6%, 5%, and 10% labeled data, respectively, outperforming all the previous methods. On WFLW and AFLW, STLD-HM-HRNet achieves the best results with 5% labeled data. In contrast, STLD-TF-HRNet performs better with higher labeled ratios, thanks to the representation capability of transformers. For example, it obtains 3.25 of NME (%) on 300W and 1.53 on AFLW with 20% labeled, both of which are slightly better than STLD-HM-HRNet. The advantage of STLD-TF-HRNet is even larger on WFLW, achieving 4.46 with 20% labeled, which is about 5.7% improvement over the best existing method HybridMatch (4.73). To make the evaluation comprehensive, we also include the results under AUC and FR-10%, which are shown in Tab.~\ref{tab:results_auc_fr}. Again, our STLD with HRNet obtains the SOTA performance on both metrics, validating the superiority of the proposed method. |