VQA-RAD
61 papers · 105 extracted observations · visual question answering · multimodal · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching regime=fine-tuned.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | BioMed-VITAL (13b, 150K) SOTA frontier | 84.86 | 2024-06-01 | epochs=15 · params=13B · backbone=LLaVA-based · training-samples=150K · LLaVA-based model; 150K training samples. Fine-tuned for 15 epochs at learning rate 2… | Biomedical Visual Instruction Tuning with Clinician Preference AlignmentSource quote{BioMed-VITAL}\xspace (13b, 150K) │ 69.72 │ 84.86 │ 91.69 │ 90.70 │ 39.89 │ 92.42 |
| 2 | MVCM | 80.93 | 2025-01-01 | MVCM was pretrained jointly on MIMIC-CXR, ROCO, and MedICaT, then fine-tuned on VQA-R… | MVCM: Enhancing Multi-View and Cross-Modality Alignment for Medical Visual Question Answering and Medical Image-Text RetrievalSource quote80.93 |
| 3 | MedVLSynther-7B | 77.57 | 2026-01-01 | params=7B · backbone=Qwen2.5-VL-7B-Instruct · training_data=MedSynVQA · training_method=reinforcement-learning · training_samples=5K · Qwen2.5-VL-7B-Instruct trained with RL on MedSynVQA; main results use 5K samples. | Synthesizing High-Quality Visual Question Answering from Medical Documents with Generator-Verifier LMMsSource quote{MedVLSynther-7B} │ 55.88 │ 22.10 │ 65.56 │ 55.43 │ 72.36 │ \multicolumn{1}{c|}{77.57} │ 58.15 |
Splittest (33)
Showing 1 of 1 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | LLaVA + CoTBox-TTT proposed | close-ended accuracy | 73.16 | split: test · test-time-training · backbone=LLaVA | CoTBox-TTT: Grounding Medical VQA with Visual Chain-of-Thought Boxes During Test-time TrainingSource quoteL235: Closed accuracy increases are consistent on all datasets and backbones, which indicates that cross\textendash view alignment stabilizes classification\textendash style questions. On VQA\textendash RAD LLaVA closed accuracy rises from 65.07 to 73.16 and Hulu\textendash Med\textendash 14B rises from 82.35 to 88.24. On SLAKE LLaVA closed accuracy rises from 63.22 to 70.43 and LLaVA\textendash Med\textendash Vicuna rises from 83.17 to 87.26. On PathVQA LLaVA closed accuracy rises from 63.20 to 75.52 and LLaVA\textendash Med\textendash BioMedCLIP rises from 91.09 to 93.02. |