VQA-RAD

61 papers · 105 extracted observations · visual question answering · multimodal · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=fine-tuned.

77.079.882.685.4202420252026BioMed-VITAL (13b, 150K): 84.86 (2024)MVCM: 80.93 (2025)MedVLSynther-7B: 77.57 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 17 of 17 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026RadGrounder (standard full multi-task mixture; frozen adapted SigLIP encoder; detection grounding) proposedF150.7split: test · fine-tuned · backbone=adapted SigLIP (frozen encoder) · training-mixture=report, VQA, SLAKE, VQA-RAD, and detection dataScalable Training of Spatially Grounded 2D Vision-Language Models for Radiology
Source quote
L139: \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 87.7 │ \showstd{2.4} │ 88.1 │ \showstd{2.4} │ 88.8 │ \showstd{2.3} │ 90.3 │ \showstd{2.7} │ 50.7 │ \showstd{3.5} │ 44.3 │ \showstd{4.8} │ 64.7 │ \showstd{4.6}
2026Qwen3.5-9B, V+K+R trace-supervised fine-tuning proposed non-standard sliceAcc83.7fine-tuned · params=9B · subset=ClinHallu · backbone=Qwen3.5-9B · supervision=full-trace (V+K+R)ClinHallu: A Benchmark for Diagnosing Stage-Wise Hallucinations in Medical MLLM Reasoning
Source quote
L538: V+K+R │ 83.7 │ 22.6 │ 4.2 │ 2.7
2026Qwen3.5-9B, V+K+R trace-supervised fine-tuning proposed non-standard slicevisual-stage hallucination rate (H^V)22.6fine-tuned · params=9B · subset=ClinHallu · backbone=Qwen3.5-9B · supervision=full-trace (V+K+R)ClinHallu: A Benchmark for Diagnosing Stage-Wise Hallucinations in Medical MLLM Reasoning
Source quote
L538: V+K+R │ 83.7 │ 22.6 │ 4.2 │ 2.7
2026FiRe-MPO (with visual preferences) proposedMed-VQA accuracy60.31%split: test · fine-tunedAnalyzing and Improving Fine-grained Preference Optimization in Medical LVLMs
Source quote
L247: {FiRe-MPO}\xspace (Ours) │ 68.14 │ 60.31 │ 80.70 │ 69.72
2026RadGrounder (external-data-only fine-tuning; no report, RefRad2D VQA, or grounding data) ablationF147.9split: test · fine-tuned · excluded-data=reports, RefRad2D VQA, and grounding · training-data=SLAKE and VQA-RAD onlyScalable Training of Spatially Grounded 2D Vision-Language Models for Radiology
Source quote
L144: \checkmark │ \checkmark │ \bestci{86.9} │ \showstd{2.5} │ \bestci{87.6} │ \showstd{2.5} │ \bestci{87.8} │ \showstd{2.4} │ 88.4 │ \showstd{3.2} │ \bestci{47.9} │ \showstd{3.4} │ 28.6 │ \showstd{4.2} │ 68.1 │ \showstd{4.4}
2026Qwen3.5-9B, w/o FT ablation non-standard sliceAcc80.4fine-tuned · params=9B · subset=ClinHallu · backbone=Qwen3.5-9B · training=no fine-tuningClinHallu: A Benchmark for Diagnosing Stage-Wise Hallucinations in Medical MLLM Reasoning
Source quote
L533: w/o FT │ 80.4 │ 32.3 │ 6.2 │ 3.3
2026Qwen3.5-9B, w/o FT ablation non-standard slicevisual-stage hallucination rate (H^V)32.3fine-tuned · params=9B · subset=ClinHallu · backbone=Qwen3.5-9B · training=no fine-tuningClinHallu: A Benchmark for Diagnosing Stage-Wise Hallucinations in Medical MLLM Reasoning
Source quote
L533: w/o FT │ 80.4 │ 32.3 │ 6.2 │ 3.3
2026FiRe-MPO w/o visual pref. ablationMed-VQA accuracy58.76%split: test · fine-tunedAnalyzing and Improving Fine-grained Preference Optimization in Medical LVLMs
Source quote
L248: w/o visual pref. │ 67.48 │ 58.76 │ 81.79 │ 69.34
2025MedVLSynther-7B proposedAccuracy77.57fine-tuned · params=7B · backbone=Qwen2.5-VL-7B-Instruct · training_data=MedSynVQA · training_method=reinforcement-learning · training_samples=5KSynthesizing High-Quality Visual Question Answering from Medical Documents with Generator-Verifier LMMs
Source quote
L279: {MedVLSynther-7B} │ 55.88 │ 22.10 │ 65.56 │ 55.43 │ 72.36 │ \multicolumn{1}{c|}{77.57} │ 58.15
2025LLaDA-MedV (benchmark-specific SD-SFT) proposed non-standard sliceaccuracy84.93%fine-tuned · subset=closed-form · inference-setting=L=B=Z=64LLaDA-MedV: Exploring Large Language Diffusion Models for Biomedical Image Understanding
Source quote
L5: Autoregressive models (ARMs) have long dominated the landscape of biomedical vision-language models (VLMs). Recently, masked diffusion models such as LLaDA have emerged as promising alternatives, yet their application in the biomedical domain remains largely underexplored. To bridge this gap, we introduce LLaDA-MedV, the first large language diffusion model tailored for biomedical image understanding through vision instruction tuning. LLaDA-MedV achieves relative performance gains of 7.855% over LLaVA-Med and 1.867% over LLaDA-V in the open-ended biomedical visual conversation task, and sets new state-of-the-art accuracy on the closed-form subset of three VQA benchmarks: 84.93% on VQA-RAD, 92.31% on SLAKE, and 95.15% on PathVQA. Furthermore, a detailed comparison with LLaVA-Med suggests that LLaDA-MedV is capable of generating reasonably longer responses by explicitly controlling response length, which can lead to more informative outputs. We also conduct an in-depth analysis of both the training and inference stages, highlighting the critical roles of initialization weight selection, fine-tuning strategies, and the interplay between sampling steps and response repetition. The code and model weight is released at \url{https://github.com/LLM-VLM-GSL/LLaDA-MedV}.
2025MVCM proposedOverall accuracy80.93fine-tunedMVCM: Enhancing Multi-View and Cross-Modality Alignment for Medical Visual Question Answering and Medical Image-Text Retrieval
Source quote
L670: 80.93
2025Phi3.5V-Med Fine-Tune (Entropy) baselineAUC0.958fine-tuned · prompt=is True · answer-type=yes/no · uncertainty-estimator=entropyUncertainty-Driven Expert Control: Enhancing the Reliability of Medical Vision-Language Models
Source quote
L304: Entropy │ 0.068 │ 0.024 │ 0.066 │ 0.958 │ 0.073 │ 0.024 │ 0.063 │ 0.949 │ \multicolumn{1}{p{11.82em}}{ ``is True'' prompt}
2024ExGra-Med (Full, α = 1.0; 10% pre-training) proposedAvg. (open- and closed-ended questions)72.52%fine-tuned · alpha=1.0 · pre-training-data=10%ExGra-Med: Extended Context Graph Alignment for Medical Vision-Language Models
Source quote
L418: ExGra-Med (Full, 10%, \alpha = 1.0) │ 72.52 │ 85.01
2024ExGra-Med (7B; 100% pre-training) proposedAvg.74.91%fine-tuned · params=7B · backbone=7B · pre-training-data=100%ExGra-Med: Extended Context Graph Alignment for Medical Vision-Language Models
Source quote
L404: ExGra-Med │ 7B │ {66.35} │ 83.46 │ 74.91 │ 85.34 │ {85.58} │ 85.46 │ 36.82 │ 90.92 │ {63.87} │ 74.75
2024HybridMED proposed non-standard sliceAccuracy0.747fine-tuned · head=two linear layers · subset=chest · pretraining-dataset=MIMIC-CXRAdvancing Medical Radiograph Representation Learning: A Hybrid Pre-training Paradigm with Multilevel Semantic Granularity
Source quote
L301: Ours │ MIMIC-CXR │ 0.747 │ 0.766
2024BioMed-VITAL (13b, 150K) proposed non-standard sliceOpen-set recall69.72fine-tuned · epochs=15 · params=13B · backbone=LLaVA-based · training-samples=150KBiomedical Visual Instruction Tuning with Clinician Preference Alignment
Source quote
L251: {BioMed-VITAL}\xspace (13b, 150K) │ 69.72 │ 84.86 │ 91.69 │ 90.70 │ 39.89 │ 92.42
2024BioMed-VITAL (13b, 150K) proposedClosed-set accuracy84.86fine-tuned · epochs=15 · params=13B · backbone=LLaVA-based · training-samples=150KBiomedical Visual Instruction Tuning with Clinician Preference Alignment
Source quote
L251: {BioMed-VITAL}\xspace (13b, 150K) │ 69.72 │ 84.86 │ 91.69 │ 90.70 │ 39.89 │ 92.42