VQA-RAD
61 papers · 105 extracted observations · visual question answering · multimodal · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching regime=fine-tuned.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | BioMed-VITAL (13b, 150K) SOTA frontier | 84.86 | 2024-06-01 | epochs=15 · params=13B · backbone=LLaVA-based · training-samples=150K · LLaVA-based model; 150K training samples. Fine-tuned for 15 epochs at learning rate 2… | Biomedical Visual Instruction Tuning with Clinician Preference AlignmentSource quote{BioMed-VITAL}\xspace (13b, 150K) │ 69.72 │ 84.86 │ 91.69 │ 90.70 │ 39.89 │ 92.42 |
| 2 | MVCM | 80.93 | 2025-01-01 | MVCM was pretrained jointly on MIMIC-CXR, ROCO, and MedICaT, then fine-tuned on VQA-R… | MVCM: Enhancing Multi-View and Cross-Modality Alignment for Medical Visual Question Answering and Medical Image-Text RetrievalSource quote80.93 |
| 3 | MedVLSynther-7B | 77.57 | 2026-01-01 | params=7B · backbone=Qwen2.5-VL-7B-Instruct · training_data=MedSynVQA · training_method=reinforcement-learning · training_samples=5K · Qwen2.5-VL-7B-Instruct trained with RL on MedSynVQA; main results use 5K samples. | Synthesizing High-Quality Visual Question Answering from Medical Documents with Generator-Verifier LMMsSource quote{MedVLSynther-7B} │ 55.88 │ 22.10 │ 65.56 │ 55.43 │ 72.36 │ \multicolumn{1}{c|}{77.57} │ 58.15 |
Splittest (33)
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | Seed1.5-VL-T (thinking mode) baseline | Consistency | 91.69% | mode=thinking · rounds=3 · temperature=0.8 | Benchmarking the Thinking Mode of Multimodal Large Language Models in Clinical TasksSource quoteL285: Seed1.5-VL-T │ 91.69% |
| 2025 | Seed1.5-VL (non-thinking mode) baseline | Consistency | 92.53% | mode=non-thinking · rounds=3 · temperature=0.8 | Benchmarking the Thinking Mode of Multimodal Large Language Models in Clinical TasksSource quoteL286: Seed1.5-VL │ 92.53% |
| 2025 | Gemini-2.5-Flash-T (thinking mode) baseline | Consistency | 78.27% | mode=thinking · rounds=3 · temperature=0.8 | Benchmarking the Thinking Mode of Multimodal Large Language Models in Clinical TasksSource quoteL287: Gemini-2.5-Flash-T │ 78.27% |
| 2025 | Gemini-2.5-Flash (non-thinking mode) baseline | Consistency | 87.08% | mode=non-thinking · rounds=3 · temperature=0.8 | Benchmarking the Thinking Mode of Multimodal Large Language Models in Clinical TasksSource quoteL288: Gemini-2.5-Flash │ 87.08% |