VQA-RAD

61 papers · 105 extracted observations · visual question answering · multimodal · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=fine-tuned.

77.079.882.685.4202420252026BioMed-VITAL (13b, 150K): 84.86 (2024)MVCM: 80.93 (2025)MedVLSynther-7B: 77.57 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 1 of 1 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025LLaVA + CoTBox-TTT proposedclose-ended accuracy73.16split: test · test-time-training · backbone=LLaVACoTBox-TTT: Grounding Medical VQA with Visual Chain-of-Thought Boxes During Test-time Training
Source quote
L235: Closed accuracy increases are consistent on all datasets and backbones, which indicates that cross\textendash view alignment stabilizes classification\textendash style questions. On VQA\textendash RAD LLaVA closed accuracy rises from 65.07 to 73.16 and Hulu\textendash Med\textendash 14B rises from 82.35 to 88.24. On SLAKE LLaVA closed accuracy rises from 63.22 to 70.43 and LLaVA\textendash Med\textendash Vicuna rises from 83.17 to 87.26. On PathVQA LLaVA closed accuracy rises from 63.20 to 75.52 and LLaVA\textendash Med\textendash BioMedCLIP rises from 91.09 to 93.02.