NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

UCR · Time Series Classification

72 papers · 197 extracted observations · tabular

Time Series Classification — Top-1 Accuracy ↑3 papers
79%81%83%85%88%202420252026NuTime, pretrained on each individual UCR dataset: 79.7 (2024)NuTime, large-scale pretraining: 86.9 (2024)TIC-FM: 80.01 (2026)TiViT (CLIP ViT-B, frozen): 80.8 (2026)Mantis + Moment (TSFM feature fusion): 81.5 (2026)TiViT (frozen OpenCLIP ViT-H, using hidden representations up to layer 14): 81.6 (2026)TiViT (CLIP ViT-B, after continual pretraining): 81.8 (2026)TiViT-CLIP + Mantis (feature fusion): 83.1 (2026)

Showing 5 of 5 matching observations. (54 non-standard slices moved to bottom.)

YearMethodMetricScoreProtocol / FacetsPaper & EvidenceReading list
2026UTICA (Teacher) proposedAccuracy0.857Time Series Classification · fine-tunedUTICA: Multi-Objective Self-Distllation Fondation Model Pretraining for Time Series Classification
Source quote
L64: Results. Figure~\ref{fig:results} displays the obtained results on UCR and UEA when models are used in frozen and fine-tuned way (see the complete results in Appendix ~\ref{app:results}). Utica consistently outperforms all baselines across benchmarks and evaluation regimes. On UCR linear probing, Utica achieves 0.794 average accuracy with 52/128 wins, versus Mantis (0.792, 33 wins) and MOMENT (0.779, 34 wins). Under fine-tuning: Utica reaches 0.857 with 60 wins versus Mantis (0.850, 38 wins). On UEA, Utica achieves the best average rank in both settings (1.60 linear probing, 1.50 fine-tuning).
2026MantisV2-FT proposedAccuracy0.85Time Series Classification · fine-tunedMantisV2: Closing the Zero-Shot Gap in Time Series Classification with Synthetic Data and Test-Time Strategies
Source quote
L62: 0.85
2026MOMENT + SVM baselineAccuracy77.98%Time Series Classification · split: test · fine-tuned · seeds=5 · backbone=MOMENT · classifier=SVM · evaluation=official-train-test-split · aggregation=average-across-datasetsBeyond Task-Specific Classifiers: In-Context Inference for Time Series Classification Foundation Models
Source quote
L357: 77.98%
2026Mantis baselineAccuracy0.850Time Series Classification · fine-tunedUTICA: Multi-Objective Self-Distllation Fondation Model Pretraining for Time Series Classification
Source quote
L64: Results. Figure~\ref{fig:results} displays the obtained results on UCR and UEA when models are used in frozen and fine-tuned way (see the complete results in Appendix ~\ref{app:results}). Utica consistently outperforms all baselines across benchmarks and evaluation regimes. On UCR linear probing, Utica achieves 0.794 average accuracy with 52/128 wins, versus Mantis (0.792, 33 wins) and MOMENT (0.779, 34 wins). Under fine-tuning: Utica reaches 0.857 with 60 wins versus Mantis (0.850, 38 wins). On UEA, Utica achieves the best average rank in both settings (1.60 linear probing, 1.50 fine-tuning).
2023NuTime (five-run fine-tuning ensemble) proposed non-standard sliceTop-1 Accuracy0.884Time Series Classification · split: test · fine-tuned · runs=five-run ensemble · epochs=500 · subset=112 sub-datasets; excludes unequal-length series and missing valuesNuTime: Numerically Multi-Scaled Embedding for Large- Scale Time-Series Pretraining
Source quote
L745: Average │ 0.884 │ 0.877 │ 0.865 │ 0.865 │ 0.858 │ 0.853 │ 0.868