UCI HAR
45 papers · 108 extracted observations · human activity recognition · Markdown · CSV · JSON API
Also indexed as: uci-har
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | KGN-HAR SOTA frontier | 97.1% | 2026-01-01 | params=0.111M · sequence-length=128 · Official train/test split; nine inertial-signal input channels and sequence length 12… | Kronecker Generative Networks: A General Neural Architecture for Parameter-Efficient Learning Across Classification TasksSource quotePAMAP2. On UCI-HAR, KGN-HAR achieves 97.10% accuracy with only 0.111M parameters, outperforming most |
| 2 | Lego CNN (o=2,m=0.5) SOTA frontier | 96.27% | 2020-05-01 | 70% of subjects used for training and 30% for testing; 128-sample sliding windows wit… | Efficient convolutional neural networks with smaller filters for human activity recognition using wearable sensors.Source quote\indent Using the above experiment configurations, we then increase the compression ratio. Fig. 4 shows the effect of increasing compression ratio on performance. Compared with the baseline CNN, the Lego CNN(o=2,m=0.5) achieves higher performance on the test set with less parameters. The Lego CNN is compared with the state-of-the-art CNN based methods in HAR, as seen in the Table III. The best published results on this task to our knowledge is 97.62% using CNN combined with hand-crafted features(Ignatov et al, 2018 {\color{black}\cite{ignatov2018real}}). To make the comparison more fair, we train the baseline CNN without using other techniques, which achieves 96.23% accuracy, almost in line with the results using CNN alone by Jiang et al \cite{jiang2015human}. Comparison shows that the Lego CNN(o=2,m=0.5) even outperforms the baseline CNN, achieving an accuracy of 96.27% with a compression ratio of 2.7x and a speedup of 2x. We argue that if parameters are not too few, parameters are enough to learn comparable or even better results. There is a continuous decrease on performance as compression ratio increases. Accuracy only drops 0.73% than the baseline CNN accompanied by a compression ratio of 5.2x and a speedup of 3.9x , which is acceptable for the mobile HAR task. |
| 3 | MLP with KNN-based defense (K=9) (+1 variant) | 93% | 2022-01-01 | model=MLP · defense=KNN (K=9) · label-flip-rate=5% · Recovered dataset after applying the KNN-based defense with K=9; 5% label-flipped dat… | Label Flipping Data Poisoning Attack Against Wearable Human Activity Recognition SystemSource quoteMLP │ 94 │ 93 │ 93 │ 91 │ 91 │ 89 │ 89 |
| 4 | Switching Gaussian process: Separate time dependence + Combined Multivariate SOTA frontier | 74.21% | 2019-01-01 | GP-setup=selected best-performing · observation-limit=observations only up to prediction time · prediction-setting=joint activity recognition and trajectory prediction · Joint activity recognition and trajectory prediction, using observations only up to t… | Adaptive Activity Monitoring with Uncertainty Quantification in Switching Gaussian Process ModelsSource quoteWe compare the activity state prediction results in two tasks. Figure \ref{gampdf} illustrates the first task, where the learned semi-Markov jump process duration distributions manifest a difference in duration between walking upstairs and downstairs compared to the other activities. Figure \ref{fullpred} demonstrates activity state prediction results in our second task. In this task, the average testing prediction accuracy can go up to 74.21%. Additionally, a large portion of inaccurate estimations are due to the time lag between the actual and predicted activity switch, which is a common problem in filtering tasks that need a certain amount of measurements in order to be confident in an activity switch. |
Regimefederated-continual-learning (6)source-free-domain-adaptation (6)continual-learning (6)unsupervised-domain-adaptation (3)federated-learning (2)class-incremental (2)
Showing 24 of 24 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | TypiCore (ASER) proposed | ACC (final average accuracy) | 69.11 | split: test · class-incremental · replay=ASER · backbone=1D-CNN | TypiCore: A Hybrid Active Query Strategy for Class-Incremental Learning on Time SeriesSource quoteL517: ACC\uparrow │ 63.00 │ 61.10 │ 62.57 │ 57.46 │ 63.03 │ 62.52 │ 69.11 |
| 2026 | KGN-HAR proposed | Accuracy | 97.10% | split: test · params=0.111M · sequence-length=128 | Kronecker Generative Networks: A General Neural Architecture for Parameter-Efficient Learning Across Classification TasksSource quoteL434: PAMAP2. On UCI-HAR, KGN-HAR achieves 97.10% accuracy with only 0.111M parameters, outperforming most |
| 2026 | AdaptHD (watermarked, ρ=1%, K=50) proposed non-standard slice | WM Acc. | 93.60% | split: test · watermarked-1 | Intellectual Property Protection of Hyperdimensional Computing Classifiers: Black-Box Ownership Verification via Model WatermarkingSource quoteL766: 93.60 |
| 2026 | CoreSet (ASER) baseline | ACC (final average accuracy) | 63.03 | split: test · class-incremental · method=CoreSet · replay=ASER · backbone=1D-CNN | TypiCore: A Hybrid Active Query Strategy for Class-Incremental Learning on Time SeriesSource quoteL517: ACC\uparrow │ 63.00 │ 61.10 │ 62.57 │ 57.46 │ 63.03 │ 62.52 │ 69.11 |
| 2024 | SensorLLM proposed | F1-macro | 91.2% | split: test · stride=64 · window-size=128 | SensorLLM: Aligning Large Language Models with Motion Sensors for Human Activity RecognitionSource quoteL208: Table~\ref{tab:stage2_results} reports the F1-macro and accuracy scores (%) averaged over five random runs. SensorLLM achieves the best performance on four out of five datasets (USC-HAD, PAMAP2, MHealth, CAPTURE-24), and ranks second on UCI-HAR, indicating strong performance across diverse sensor settings. On CAPTURE-24, SensorLLM reaches 48.6% F1-macro, a +5.0% absolute gain over Attend (43.6%). It also leads on USC-HAD (61.2%, +1.0%), PAMAP2 (86.2%, +1.6%), and MHealth (89.4%, +6.0%), establishing state-of-the-art performance on these datasets. On UCI-HAR, SensorLLM achieves 91.2%, slightly below Attend (93.2%). |
| 2023 | FC-STGNN (Complete) proposed | Accu. | 95.81 | split: test | Fully-Connected Spatial-Temporal Graph for Multivariate Time Series DataSource quoteL152: Complete │ 11.62 │ 203 │ 13.04 │ 738 │ 11.52 │ 198 │ 13.62 │ 816 │ 95.81 │ 95.82 │ 80.87 │ 78.79 |
| 2023 | FC-STGNN variant w/o FC GC^2 ablation | Accu. | 94.79 | split: test | Fully-Connected Spatial-Temporal Graph for Multivariate Time Series DataSource quoteL148: w/o FC GC^2 │ 12.58 │ 237 │ 13.78 │ 849 │ 11.92 │ 218 │ 14.44 │ 967 │ 94.79 │ 94.82 │ 79.62 │ 77.57 |
| 2022 | MLP with KNN-based defense (K=9) proposed | Accuracy | 93% | split: test · model=MLP · defense=KNN (K=9) · label-flip-rate=5% | Label Flipping Data Poisoning Attack Against Wearable Human Activity Recognition SystemSource quoteL239: MLP │ 94 │ 93 │ 93 │ 91 │ 91 │ 89 │ 89 |
| 2022 | MLP with KNN-based defense (K=9) proposed | Accuracy | 91% | split: test · model=MLP · defense=KNN (K=9) · label-flip-rate=15% | Label Flipping Data Poisoning Attack Against Wearable Human Activity Recognition SystemSource quoteL239: MLP │ 94 │ 93 │ 93 │ 91 │ 91 │ 89 │ 89 |
| 2022 | MLP (non-adversarial baseline) baseline non-standard slice | Accuracy | 94% | split: test · model=MLP · test-fraction=25% · data-partition=by-volunteer · train-fraction=75% | Label Flipping Data Poisoning Attack Against Wearable Human Activity Recognition SystemSource quoteL193: Accuracy \rightarrow │ 94 │ 86 │ 92 │ 96 |
| 2021 | FLwF-2T proposed | General accuracy (A_gen^1) | 0.655 | split: test · continual-learning · client=1 · exemplars=none | A distillation-based approach integrating continual learning and federated learning for pervasive servicesSource quoteL356: FLwF-2T │ 0.655 │ 0.679 │ 0.680 │ 0.629 [0.05cm] |
| 2021 | RFAAE baseline non-standard slice | Downstream classification performance (specific measure not disambiguated in the cited prose) | 88.5% | split: test · linear-probe | Guided-GAN: Adversarial Representation Learning for Activity Recognition with WearablesSource quoteL159: Across the three datasets, the large performance gap between RGAN (80.2%, 76.3% and 50.7% respectively) against RFAAE (94%, 88.5% and 64.4%) highlights the significance of incorporating an inference network for effective representation learning in generative adversarial frameworks. While the discriminator's delegated task of distinguishing between real and generated sequences benefits the penultimate representations (see the superiority of RGAN over RAND baseline), learning an inverse mapping to the latent feature space through encoder results in significantly more effective features. However, the encoder in RFAAE is only trained on synthetic sequences and never encounters real data samples. Accordingly, its performance as a feature extractor is heavily reliant on the quality and diversity of the generator's sequences. In contrast, the encoder in our framework, exposed to both real data sequences as well as generated ones evidently offers feature representations of higher quality, achieving 3.51%, 0.56% and 4.35% relative improvements, respectively, on Sequential \texttt{MNIST}, \texttt{UCI HAR} and \texttt{USC-HAD} datasets. |
| 2021 | FLwF baseline | General accuracy (A_gen^1) | 0.629 | split: test · continual-learning · client=1 · exemplars=none | A distillation-based approach integrating continual learning and federated learning for pervasive servicesSource quoteL355: FLwF │ 0.629 │ 0.673 │ 0.671 │ 0.628 |
| 2020 | Lego CNN (o=2,m=0.5) | Accuracy | 96.27% | split: test | Efficient convolutional neural networks with smaller filters for human activity recognition using wearable sensors.Source quoteL151: \indent Using the above experiment configurations, we then increase the compression ratio. Fig. 4 shows the effect of increasing compression ratio on performance. Compared with the baseline CNN, the Lego CNN(o=2,m=0.5) achieves higher performance on the test set with less parameters. The Lego CNN is compared with the state-of-the-art CNN based methods in HAR, as seen in the Table III. The best published results on this task to our knowledge is 97.62% using CNN combined with hand-crafted features(Ignatov et al, 2018 {\color{black}\cite{ignatov2018real}}). To make the comparison more fair, we train the baseline CNN without using other techniques, which achieves 96.23% accuracy, almost in line with the results using CNN alone by Jiang et al \cite{jiang2015human}. Comparison shows that the Lego CNN(o=2,m=0.5) even outperforms the baseline CNN, achieving an accuracy of 96.27% with a compression ratio of 2.7x and a speedup of 2x. We argue that if parameters are not too few, parameters are enough to learn comparable or even better results. There is a continuous decrease on performance as compression ratio increases. Accuracy only drops 0.73% than the baseline CNN accompanied by a compression ratio of 5.2x and a speedup of 3.9x , which is acceptable for the mobile HAR task. |
| 2020 | CPC with learned g_enc≤2 weights | test mean F1-score | 82.58% | split: test | Contrastive Predictive Coding for Human Activity RecognitionSource quoteL526: We observe a mean f1-score of 82.58%, which is higher than the best unsupervised representation learned by masked reconstruction (Tab.\ \ref{tab:representation_learning}) and comparable to DeepConvLSTM, which exceeds all other approaches. |
| 2020 | Baseline CNN baseline | Accuracy | 96.23% | split: test | Efficient convolutional neural networks with smaller filters for human activity recognition using wearable sensors.Source quoteL151: \indent Using the above experiment configurations, we then increase the compression ratio. Fig. 4 shows the effect of increasing compression ratio on performance. Compared with the baseline CNN, the Lego CNN(o=2,m=0.5) achieves higher performance on the test set with less parameters. The Lego CNN is compared with the state-of-the-art CNN based methods in HAR, as seen in the Table III. The best published results on this task to our knowledge is 97.62% using CNN combined with hand-crafted features(Ignatov et al, 2018 {\color{black}\cite{ignatov2018real}}). To make the comparison more fair, we train the baseline CNN without using other techniques, which achieves 96.23% accuracy, almost in line with the results using CNN alone by Jiang et al \cite{jiang2015human}. Comparison shows that the Lego CNN(o=2,m=0.5) even outperforms the baseline CNN, achieving an accuracy of 96.27% with a compression ratio of 2.7x and a speedup of 2x. We argue that if parameters are not too few, parameters are enough to learn comparable or even better results. There is a continuous decrease on performance as compression ratio increases. Accuracy only drops 0.73% than the baseline CNN accompanied by a compression ratio of 5.2x and a speedup of 3.9x , which is acceptable for the mobile HAR task. |
| 2019 | DDNN proposed | miF (Micro-F1) | 90.53% | split: test · window=2.56 seconds · train-test-split=70/30 by volunteer | A Novel Distribution-Embedded Neural Network for Sensor-Based Activity RecognitionSource quoteL246: 90.53 |
| 2019 | Switching Gaussian process: Separate time dependence + Combined Multivariate proposed | Average testing activity prediction accuracy | 74.21% | split: test · GP-setup=selected best-performing · observation-limit=observations only up to prediction time · prediction-setting=joint activity recognition and trajectory prediction | Adaptive Activity Monitoring with Uncertainty Quantification in Switching Gaussian Process ModelsSource quoteL249: We compare the activity state prediction results in two tasks. Figure \ref{gampdf} illustrates the first task, where the learned semi-Markov jump process duration distributions manifest a difference in duration between walking upstairs and downstairs compared to the other activities. Figure \ref{fullpred} demonstrates activity state prediction results in our second task. In this task, the average testing prediction accuracy can go up to 74.21%. Additionally, a large portion of inaccurate estimations are due to the time lag between the actual and predicted activity switch, which is a common problem in filtering tasks that need a certain amount of measurements in order to be confident in an activity switch. |
| 2018 | U-Net proposed | Acc | 0.984 | split: test · test-size=30% · evaluation=dense-pointwise | Human activity recognition based on time series analysis using U-NetSource quoteL517: 0.984 |
| 2018 | CNN baseline | Acc | 0.950 | split: test · test-size=30% · evaluation=dense-pointwise | Human activity recognition based on time series analysis using U-NetSource quoteL515: 0.950 |
| 2015 | DTW with DBA proposed | Test Accuracy | 0.860 | split: test · cut=0.25 · preprocessing=flat curves removed · activity-classes=6 | Multivariate Time Series Classification Using Dynamic Time Warping Template Selection for Human Activity RecognitionSource quoteL365: 0.25 │ 0.841 (0.966) │ 0.860 (0.977) |
| 2015 | DTWsubseq with DBA proposed | Test Accuracy | 0.977 | split: test · cut=0.25 · preprocessing=flat curves removed · activity-classes=4; static activities combined | Multivariate Time Series Classification Using Dynamic Time Warping Template Selection for Human Activity RecognitionSource quoteL358: 0.25 │ 0.838 (0.974) │ 0.855 (0.977) |
| 2015 | Feature extraction (568 features; PCA and linear SVM) baseline | Accuracy | 0.890 | split: test · features=568 · classifier=linear SVM · preprocessing=flat curves removed · dimensionality-reduction=PCA | Multivariate Time Series Classification Using Dynamic Time Warping Template Selection for Human Activity RecognitionSource quoteL405: 0.890 (0.965) │ 0.67 |
| 2015 | Feature extraction (568 features; PCA and linear SVM) baseline | Accuracy | 0.965 | split: test · features=568 · classifier=linear SVM · activity-classes=4; static activities combined · dimensionality-reduction=PCA | Multivariate Time Series Classification Using Dynamic Time Warping Template Selection for Human Activity RecognitionSource quoteL405: 0.890 (0.965) │ 0.67 |