UCI HAR

45 papers · 108 extracted observations · human activity recognition · Markdown · CSV · JSON API

Also indexed as: uci-har

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

72.481.290.198.9201920222026Switching Gaussian process: Separate time dependence + Combined Multivariate: 74.21 (2019)Lego CNN (o=2,m=0.5): 96.27 (2020)MLP with KNN-based defense (K=9): 91.0 (2022)MLP with KNN-based defense (K=9): 93.0 (2022)KGN-HAR: 97.1 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 13 of 13 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026TypiCore (ASER) proposedACC (final average accuracy)69.11split: test · class-incremental · replay=ASER · backbone=1D-CNNTypiCore: A Hybrid Active Query Strategy for Class-Incremental Learning on Time Series
Source quote
L517: ACC\uparrow │ 63.00 │ 61.10 │ 62.57 │ 57.46 │ 63.03 │ 62.52 │ 69.11
2026KGN-HAR proposedAccuracy97.10%split: test · params=0.111M · sequence-length=128Kronecker Generative Networks: A General Neural Architecture for Parameter-Efficient Learning Across Classification Tasks
Source quote
L434: PAMAP2. On UCI-HAR, KGN-HAR achieves 97.10% accuracy with only 0.111M parameters, outperforming most
2026AdaptHD (watermarked, ρ=1%, K=50) proposed non-standard sliceWM Acc.93.60%split: test · watermarked-1Intellectual Property Protection of Hyperdimensional Computing Classifiers: Black-Box Ownership Verification via Model Watermarking
Source quote
L766: 93.60
2024SensorLLM proposedF1-macro91.2%split: test · stride=64 · window-size=128SensorLLM: Aligning Large Language Models with Motion Sensors for Human Activity Recognition
Source quote
L208: Table~\ref{tab:stage2_results} reports the F1-macro and accuracy scores (%) averaged over five random runs. SensorLLM achieves the best performance on four out of five datasets (USC-HAD, PAMAP2, MHealth, CAPTURE-24), and ranks second on UCI-HAR, indicating strong performance across diverse sensor settings. On CAPTURE-24, SensorLLM reaches 48.6% F1-macro, a +5.0% absolute gain over Attend (43.6%). It also leads on USC-HAD (61.2%, +1.0%), PAMAP2 (86.2%, +1.6%), and MHealth (89.4%, +6.0%), establishing state-of-the-art performance on these datasets. On UCI-HAR, SensorLLM achieves 91.2%, slightly below Attend (93.2%).
2023FC-STGNN (Complete) proposedAccu.95.81split: testFully-Connected Spatial-Temporal Graph for Multivariate Time Series Data
Source quote
L152: Complete │ 11.62 │ 203 │ 13.04 │ 738 │ 11.52 │ 198 │ 13.62 │ 816 │ 95.81 │ 95.82 │ 80.87 │ 78.79
2022MLP with KNN-based defense (K=9) proposedAccuracy93%split: test · model=MLP · defense=KNN (K=9) · label-flip-rate=5%Label Flipping Data Poisoning Attack Against Wearable Human Activity Recognition System
Source quote
L239: MLP │ 94 │ 93 │ 93 │ 91 │ 91 │ 89 │ 89
2022MLP with KNN-based defense (K=9) proposedAccuracy91%split: test · model=MLP · defense=KNN (K=9) · label-flip-rate=15%Label Flipping Data Poisoning Attack Against Wearable Human Activity Recognition System
Source quote
L239: MLP │ 94 │ 93 │ 93 │ 91 │ 91 │ 89 │ 89
2021FLwF-2T proposedGeneral accuracy (A_gen^1)0.655split: test · continual-learning · client=1 · exemplars=noneA distillation-based approach integrating continual learning and federated learning for pervasive services
Source quote
L356: FLwF-2T │ 0.655 │ 0.679 │ 0.680 │ 0.629 [0.05cm]
2019DDNN proposedmiF (Micro-F1)90.53%split: test · window=2.56 seconds · train-test-split=70/30 by volunteerA Novel Distribution-Embedded Neural Network for Sensor-Based Activity Recognition
Source quote
L246: 90.53
2019Switching Gaussian process: Separate time dependence + Combined Multivariate proposedAverage testing activity prediction accuracy74.21%split: test · GP-setup=selected best-performing · observation-limit=observations only up to prediction time · prediction-setting=joint activity recognition and trajectory predictionAdaptive Activity Monitoring with Uncertainty Quantification in Switching Gaussian Process Models
Source quote
L249: We compare the activity state prediction results in two tasks. Figure \ref{gampdf} illustrates the first task, where the learned semi-Markov jump process duration distributions manifest a difference in duration between walking upstairs and downstairs compared to the other activities. Figure \ref{fullpred} demonstrates activity state prediction results in our second task. In this task, the average testing prediction accuracy can go up to 74.21%. Additionally, a large portion of inaccurate estimations are due to the time lag between the actual and predicted activity switch, which is a common problem in filtering tasks that need a certain amount of measurements in order to be confident in an activity switch.
2018U-Net proposedAcc0.984split: test · test-size=30% · evaluation=dense-pointwiseHuman activity recognition based on time series analysis using U-Net
Source quote
L517: 0.984
2015DTW with DBA proposedTest Accuracy0.860split: test · cut=0.25 · preprocessing=flat curves removed · activity-classes=6Multivariate Time Series Classification Using Dynamic Time Warping Template Selection for Human Activity Recognition
Source quote
L365: 0.25 │ 0.841 (0.966) │ 0.860 (0.977)
2015DTWsubseq with DBA proposedTest Accuracy0.977split: test · cut=0.25 · preprocessing=flat curves removed · activity-classes=4; static activities combinedMultivariate Time Series Classification Using Dynamic Time Warping Template Selection for Human Activity Recognition
Source quote
L358: 0.25 │ 0.838 (0.974) │ 0.855 (0.977)