UBFC

15 papers · 29 extracted observations · heart rate estimation · Markdown · CSV · JSON API

Showing 20 of 20 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026StreamPPG (frame-wise) proposedThroughput290 fpsHeart Rate Estimation · processing=frame-wiseStreamPPG: Low-Latency rPPG Estimation via Consistent Privileged Learning
Source quote
L394: StreamPPG │ F │ 2.92 │ 1.59 │ 290 │ 405.75 │ 0.27
2026StreamPPG (frame-wise) proposedRMSE0.27 bpmHeart Rate Estimation · processing=frame-wiseStreamPPG: Low-Latency rPPG Estimation via Consistent Privileged Learning
Source quote
L394: StreamPPG │ F │ 2.92 │ 1.59 │ 290 │ 405.75 │ 0.27
2026StreamPPG proposedRMSE0.22 bpmHeart Rate Estimation · resolution=256×256 · hardware=Jetson AGX OrinStreamPPG: Low-Latency rPPG Estimation via Consistent Privileged Learning
Source quote
L412: StreamPPG │ 56 │ 0.31 │ 54 │ 0.27 │ 53 │ 0.27 │ 54 │ 0.22
2025CiCi proposedMAE3.55Heart Rate Estimation · split: test · test-time-adaptation · training=HSRD-trained on other four datasetsNot Only Consistency: Enhance Test-Time Adaptation with Spatio-temporal Inconsistency for Remote Physiological Measurement
Source quote
L197: CiCi │ 3.55\(^*\) │ 6.27\(^*\) │ 0.89 │ 4.96\(^*\) │ 7.99\(^*\) │ 0.90\(^*\) │ 1.49\(^*\) │ 1.96\(^*\) │ 0.99 │ 6.87\(^*\) │ 10.59\(^*\) │ 0.64\(^*\) │ 8.58\(^*\) │ 11.03\(^*\) │ 0.54\(^*\)
2024TSCAN-TN proposedMAE0.519Heart Rate Estimation · training-dataset=MMPDA Plug-and-Play Temporal Normalization Module for Robust Remote Photoplethysmography
Source quote
L293: The TN module can improve training performance on complex, high-noise real-world datasets. MMPD \cite{tang2023mmpd}, recognized as a challenging dataset for real-world validation, is difficult to train on due to significant video compression and motion noise. Most previous research either failed to train on the full MMPD dataset \cite{Liu2024SpikingPhysFormerCR} or opted to train on a subset\cite{Zhao_2024_CVPR}. In contrast, our TN module enables all methods to successfully train on the entire MMPD dataset in Table \ref{resultmmpd}, with performance gains ranging from 34.3% to 98.8%. Moreover, it helps achieve clinical-level accuracy (MAE below 2) in cross-dataset experiments: 1.114 with TN-Net on RLAP, 2.042 with PhysNet-TN on COHFACE, 0.622 with TN-Net on PURE, and 0.519 with TSCAN-TN on UBFC.
2024PhysMLE-R proposedHR MAE4.353 bpmHeart Rate Estimation · split: test · cross-domain · protocol=MSSDG Protocol IPhysMLE: Generalizable and Priors-Inclusive Multi-Task Remote Physiological Measurement
Source quote
L382: PhysMLE-R │ 0.056 │ 0.073 │ 0.248 │ 0.056 │ 0.073 │ 0.248 │ 0.223 │ 0.296 │ 0.345 │ 4.353 │ 5.081 │ 0.850
2024Bi-TTA proposedM↓ (MAE)3.53Heart Rate EstimationBi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement
Source quote
L233: Ours │ \textbf{{7.09}} │ \textbf{{10.72}} │ \textbf{{0.63}} │ 9.1 │ 11.02 │ 0.54 │ \textbf{{5.02}} │ \textbf{{8.11}} │ \textbf{{0.890}} │ 3.53 │ 6.24 │ 0.891 │ \textbf{{1.49}} │ \textbf{{1.97}} │ \textbf{{0.99}}
2023Proposed method (eight selected augmentation operations) proposedMAE1.799Heart Rate Estimation · split: test · model=TSCAN · augmentation=eight selected operations · training-data=SCAMPSTraining Robust Deep Physiological Measurement Models with Synthetic Video-based Data
Source quote
L236: UBFC │ 1.799 │ 3.723 │ 1.928 │ 0.980
2023NEST proposedHR MAE↓4.7471 bpmHeart Rate Estimation · split: test · evaluation=MSDG · training-datasets=PURE, BUAA, VIPL, V4VNeuron Structure Modeling for Generalizable Remote Physiological Measurement
Source quote
L197: NEST │ 0.0597 │ 0.0782 │ 0.2017 │ 0.0597 │ 0.0782 │ 0.2017 │ 0.2138 │ 0.2824 │ 0.3179 │ 4.7471 │ 6.8876 │ 0.8546
2023RoI+Sh+B (U) proposedMAE0.89Heart Rate Estimation · method=RoI extraction, shuffling, blurring · key-selection=unbounded randomizedPrivacy-Preserving Remote Heart Rate Estimation from Facial Videos
Source quote
L188: Ours │ 0.96 │ 1.30 │ 0.99 │ 0.89 │ 1.24 │ 0.99
2022Beam AI SDK proposedaccuracy (heart rate estimation)99.2%Heart Rate EstimationReal-Time Monitoring of User Stress, Heart Rate and Heart Rate Variability on Mobile Devices
Source quote
L4: Stress is considered to be the epidemic of the 21st-century \cite{Fink2016_StressEpidemic}. Yet, mobile apps cannot directly evaluate the impact of their content and services on user stress. We introduce the Beam AI SDK to address this issue. Using our SDK, apps can monitor user stress through the selfie camera in real-time. Our technology extracts the user’s pulse wave by analyzing subtle color variations across the skin regions of the user’s face. The user’s pulse wave is then used to determine stress (according to the Baevsky Stress Index), heart rate, and heart rate variability. We evaluate our technology on the UBFC dataset, the MMSE-HR dataset, and Beam AI's internal data. Our technology achieves 99.2%, 97.8% and 98.5% accuracy for heart rate estimation on each benchmark respectively, a nearly twice lower error rate than competing methods. We further demonstrate an average Pearson correlation of 0.801 in determining stress and heart rate variability, thus producing commercially useful readings to derive content decisions in apps. Our SDK is available for use\footnote{Visit \url{beamhealth.ai} for more information. The Beam AI SDK (iOS) files can be accessed at \url{github.com/beamai/BeamAISDK-iOS}. SDK access keys can be obtained by signing up at \url{dashboard.beamhealth.ai}.}.
2022Beam AI SDK proposed non-standard sliceMAE (heart rate estimation)0.65 beats per minuteHeart Rate Estimation · fps=30 FPS · frame-rate=30 fpsReal-Time Monitoring of User Stress, Heart Rate and Heart Rate Variability on Mobile Devices
Source quote
L33: Beam AI SDK │ 0.65 │ 0.77% │ 1.98 │ 0.99
2022FedWeight (signal-quality-weighted averaging) proposedMAE (HR estimation)4.59 beats/minHeart Rate Estimation · federated · training-data=AFRL · video-noise-level=1.50Federated Remote Physiological Measurement with Imperfect Data
Source quote
L137: 1.50 │ 7.44 │ 4.59 │ -2.33 │ -0.03 │ 0.66 │ 0.79
2022FedWeight (signal-quality-weighted averaging) proposed non-standard sliceBVP Signal-to-Noise Ratio (SNR)-0.03 dBBlood Volume Pulse Signal Quality · federated · training-data=AFRL · video-noise-level=1.50Federated Remote Physiological Measurement with Imperfect Data
Source quote
L137: 1.50 │ 7.44 │ 4.59 │ -2.33 │ -0.03 │ 0.66 │ 0.79
2021Paper's contrastive (self-supervised) system proposed non-standard sliceRMSE4.6Heart Rate Estimation · self-supervisedThe Way to my Heart is through Contrastive Learning: Remote Photoplethysmography from Unlabelled Video
Source quote
L217: UBFC. Lastly, we consider the UBFC dataset, comparing against the 7.4 RMSE baseline from~\cite{lee_meta-rppg_2020}. Note they instead use the first two seconds of all samples for adaptation, so the results are not perfectly comparable. Our supervised (4.9 RMSE) and contrastive (4.6 RMSE) methods both achieve a similar, improved performance.
2021Paper's supervised system proposed non-standard sliceRMSE4.9Heart Rate Estimation · supervisedThe Way to my Heart is through Contrastive Learning: Remote Photoplethysmography from Unlabelled Video
Source quote
L217: UBFC. Lastly, we consider the UBFC dataset, comparing against the 7.4 RMSE baseline from~\cite{lee_meta-rppg_2020}. Note they instead use the first two seconds of all samples for adaptation, so the results are not perfectly comparable. Our supervised (4.9 RMSE) and contrastive (4.6 RMSE) methods both achieve a similar, improved performance.
2021EfficientPhys-C proposedPearson correlation0.99Heart Rate EstimationEfficientPhys: Enabling Simple, Fast and Accurate Camera-Based Cardiac Measurement
Source quote
L188: To conduct a fair comparison with the current state-of-the-art methods, we followed Dual-GAN \cite{lu2021dual} to train our models in PURE only and to test on UBFC as Table \ref{tab:cross_pure_ubfc} shows. Although Dual-GAN outperforms all of other methods, we argue that the margin is relatively small as both Dual-GAN and EfficientPhys-C achieve a Pearson correlation of 0.99. Moreover, according to American National Standards Institute (ANSI) and Consumer Technology Association's standard \cite{consumer2018physical}, MAPE of ±5 is an acceptable error rate. Various studies have also used this standard to validate FDA approved sensors and systems \cite{nelson2019accuracy,shcherbina2017accuracy,reece2021assessing,carrier2020validity}. All the methods in Table \ref{tab:cross_pure_ubfc} have met this recommended bar.
2020MetaPhys, supervised with pretraining proposedMAE1.90 BPMHeart Rate Estimation · pretraining=with-pretraining · training-regime=supervisedMetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological Measurement
Source quote
L166: Next, we examine the difference between a supervised and unsupervised training regime in MetaPhys\xspace. For UBFC, the supervised model (MAE=1.90 BPM), outperformed the unsupervised model (MAE=2.46 BPM). Whereas, for the MMSE dataset the unsupervised model (MAE=1.87 BMP) outperformed the supervised model (MAE=2.98 BMP). The fact that the unsupervised model achieves broadly comparable results to the supervised model is surprising and encouraging because there are many applications where unsupervised adaptation would be more convenient and efficient (e.g., calibrating a heart rate measurement app on a smartphone without needing a reference device). We also observe that the unsupervised model, even though it used the POS signal as training input, significantly outperforms POS on both datasets, suggesting MetaPhys\xspace is able to form a better representation.
2020MetaPhys, unsupervised with pretraining proposedMAE2.46 BPMHeart Rate Estimation · pretraining=with-pretraining · training-regime=unsupervisedMetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological Measurement
Source quote
L166: Next, we examine the difference between a supervised and unsupervised training regime in MetaPhys\xspace. For UBFC, the supervised model (MAE=1.90 BPM), outperformed the unsupervised model (MAE=2.46 BPM). Whereas, for the MMSE dataset the unsupervised model (MAE=1.87 BMP) outperformed the supervised model (MAE=2.98 BMP). The fact that the unsupervised model achieves broadly comparable results to the supervised model is surprising and encouraging because there are many applications where unsupervised adaptation would be more convenient and efficient (e.g., calibrating a heart rate measurement app on a smartphone without needing a reference device). We also observe that the unsupervised model, even though it used the POS signal as training input, significantly outperforms POS on both datasets, suggesting MetaPhys\xspace is able to form a better representation.
2020MetaPhys, unsupervised with pretraining proposedMAE reduction44%Heart Rate Estimation · pretraining=with-pretraining · training-regime=unsupervisedMetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological Measurement
Source quote
L163: In this section, we compare the performance of MetaPhys\xspace with other state-of-the-art approaches using Mean Absolute Error(MAE) of heart rate. Details of the evaluation metrics are in the Appendix section. For the MMSE dataset, our proposed supervised and unsupervised MetaPhys\xspace with pretraining outperformed the state-of-the-art results by 7% and 42% in MAE, respectively (see Table \ref{tab:AFRL_MMSE}). On the UBFC dataset, supervised and unsupervised MetaPhys\xspace with pretraining showed even greater benefits reducing error by 57% and 44% compared to the previous state-of-the-art, respectively. Meta-learning alone is not as effective as meta-learning using weights initialized in a pretraining stage (19% and 50% improvements in MMSE and UBFC). We also compared our methods against the only other meta-learning based method (Meta-rPPG) where we reduced the MAE by 68%. Furthermore, we compared MetaPhys\xspace against a traditional personalization method (fine-tuning), and our approach gained 54% and a 61% improvements in terms of MAE on MMSE and UBFC, respectively. We also evaluated performance using different time windows in the support set (6s, 12s and 18s), and the results showed training with 18s (RMSE: 3.12) outperformed 6s (RMSE: 5.43) and 12s (RMSE: 5.53) on the MMSE dataset. A similar trend was also observed on the UBFC dataset (RMSE of 18s: 3.12, RMSE of 12s: 4.48, RMSE of 6s: 3.46). Fig. \ref{fig:blandaltman} compares the heart rate estimates from MetaPhys\xspace and the-state-of-art algorithm (TS-CAN \cite{liu2020multi}) (y-axes) to the gold-standard measurements (x-axes). The strong correlation coefficients and bias/limits in the Bland-Altman plots presented support that MetaPhys\xspace can produce more accurate and reliable estimates. Our results from unsupervised MetaPhys\xspace indicate that pesudo labels provided by a relatively simple de-mixing approach (POS) can be used in a meta-learning context to obtain strong results. The training with these pseudo labels, sometimes with noisy labels, well outperforms the de-mixing approach itself.