UBFC
15 papers · 29 extracted observations · heart rate estimation · Markdown · CSV · JSON API
Metricmae (19)rmse (4)bvp signal to noise ratio snr (2)pearson correlation (2)accuracy (1)throughput (1)
Splittest (5)
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2022 | FedWeight (signal-quality-weighted averaging) proposed | MAE (HR estimation) | 4.59 beats/min | Heart Rate Estimation · federated · training-data=AFRL · video-noise-level=1.50 | Federated Remote Physiological Measurement with Imperfect DataSource quoteL137: 1.50 │ 7.44 │ 4.59 │ -2.33 │ -0.03 │ 0.66 │ 0.79 |
| 2022 | FedWeight (signal-quality-weighted averaging) proposed non-standard slice | BVP Signal-to-Noise Ratio (SNR) | -0.03 dB | Blood Volume Pulse Signal Quality · federated · training-data=AFRL · video-noise-level=1.50 | Federated Remote Physiological Measurement with Imperfect DataSource quoteL137: 1.50 │ 7.44 │ 4.59 │ -2.33 │ -0.03 │ 0.66 │ 0.79 |
| 2022 | FedAvg baseline | MAE (HR estimation) | 7.44 beats/min | Heart Rate Estimation · federated · training-data=AFRL · video-noise-level=1.50 | Federated Remote Physiological Measurement with Imperfect DataSource quoteL137: 1.50 │ 7.44 │ 4.59 │ -2.33 │ -0.03 │ 0.66 │ 0.79 |
| 2022 | FedAvg baseline non-standard slice | BVP Signal-to-Noise Ratio (SNR) | -2.33 dB | Blood Volume Pulse Signal Quality · federated · training-data=AFRL · video-noise-level=1.50 | Federated Remote Physiological Measurement with Imperfect DataSource quoteL137: 1.50 │ 7.44 │ 4.59 │ -2.33 │ -0.03 │ 0.66 │ 0.79 |