UBFC
15 papers · 29 extracted observations · heart rate estimation · Markdown · CSV · JSON API
Metricmae (19)rmse (4)bvp signal to noise ratio snr (2)pearson correlation (2)accuracy (1)throughput (1)
Splittest (5)
Showing 19 of 19 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | CiCi proposed | MAE | 3.55 | Heart Rate Estimation · split: test · test-time-adaptation · training=HSRD-trained on other four datasets | Not Only Consistency: Enhance Test-Time Adaptation with Spatio-temporal Inconsistency for Remote Physiological MeasurementSource quoteL197: CiCi │ 3.55\(^*\) │ 6.27\(^*\) │ 0.89 │ 4.96\(^*\) │ 7.99\(^*\) │ 0.90\(^*\) │ 1.49\(^*\) │ 1.96\(^*\) │ 0.99 │ 6.87\(^*\) │ 10.59\(^*\) │ 0.64\(^*\) │ 8.58\(^*\) │ 11.03\(^*\) │ 0.54\(^*\) |
| 2024 | TSCAN-TN proposed | MAE | 0.519 | Heart Rate Estimation · training-dataset=MMPD | A Plug-and-Play Temporal Normalization Module for Robust Remote PhotoplethysmographySource quoteL293: The TN module can improve training performance on complex, high-noise real-world datasets. MMPD \cite{tang2023mmpd}, recognized as a challenging dataset for real-world validation, is difficult to train on due to significant video compression and motion noise. Most previous research either failed to train on the full MMPD dataset \cite{Liu2024SpikingPhysFormerCR} or opted to train on a subset\cite{Zhao_2024_CVPR}. In contrast, our TN module enables all methods to successfully train on the entire MMPD dataset in Table \ref{resultmmpd}, with performance gains ranging from 34.3% to 98.8%. Moreover, it helps achieve clinical-level accuracy (MAE below 2) in cross-dataset experiments: 1.114 with TN-Net on RLAP, 2.042 with PhysNet-TN on COHFACE, 0.622 with TN-Net on PURE, and 0.519 with TSCAN-TN on UBFC. |
| 2024 | PhysMLE-R proposed | HR MAE | 4.353 bpm | Heart Rate Estimation · split: test · cross-domain · protocol=MSSDG Protocol I | PhysMLE: Generalizable and Priors-Inclusive Multi-Task Remote Physiological MeasurementSource quoteL382: PhysMLE-R │ 0.056 │ 0.073 │ 0.248 │ 0.056 │ 0.073 │ 0.248 │ 0.223 │ 0.296 │ 0.345 │ 4.353 │ 5.081 │ 0.850 |
| 2024 | Bi-TTA proposed | M↓ (MAE) | 3.53 | Heart Rate Estimation | Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological MeasurementSource quoteL233: Ours │ \textbf{{7.09}} │ \textbf{{10.72}} │ \textbf{{0.63}} │ 9.1 │ 11.02 │ 0.54 │ \textbf{{5.02}} │ \textbf{{8.11}} │ \textbf{{0.890}} │ 3.53 │ 6.24 │ 0.891 │ \textbf{{1.49}} │ \textbf{{1.97}} │ \textbf{{0.99}} |
| 2024 | PhysNet + FWD loss ablation | MAE | 0.83 bpm | Heart Rate Estimation · split: test · supervised · loss=Negative Pearson + FWD · backbone=PhysNet · train-dataset=PURE | SFDA-rPPG: Source-Free Domain Adaptive Remote Physiological Measurement with Spatio-Temporal ConsistencySource quoteL345: PURE │ 0.83 │ 1.73 │ 0.99 │ 0.22 │ 1.05 │ 0.99 |
| 2024 | ConPhys | M↓ (MAE) | 3.92 | Heart Rate Estimation | Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological MeasurementSource quoteL225: ConPhys\empty^{\ref{fn:conphys}} \cite{sun2022contrast} │ 7.43 │ 10.7 │ 0.61 │ 9.3 │ 10.96 │ 0.52 │ 6.09 │ 8.83 │ 0.88 │ 3.92 │ 6.61 │ 0.886 │ 1.75 │ 2.19 │ 0.97 |
| 2023 | Proposed method (eight selected augmentation operations) proposed | MAE | 1.799 | Heart Rate Estimation · split: test · model=TSCAN · augmentation=eight selected operations · training-data=SCAMPS | Training Robust Deep Physiological Measurement Models with Synthetic Video-based DataSource quoteL236: UBFC │ 1.799 │ 3.723 │ 1.928 │ 0.980 |
| 2023 | NEST proposed | HR MAE↓ | 4.7471 bpm | Heart Rate Estimation · split: test · evaluation=MSDG · training-datasets=PURE, BUAA, VIPL, V4V | Neuron Structure Modeling for Generalizable Remote Physiological MeasurementSource quoteL197: NEST │ 0.0597 │ 0.0782 │ 0.2017 │ 0.0597 │ 0.0782 │ 0.2017 │ 0.2138 │ 0.2824 │ 0.3179 │ 4.7471 │ 6.8876 │ 0.8546 |
| 2023 | RoI+Sh+B (U) proposed | MAE | 0.89 | Heart Rate Estimation · method=RoI extraction, shuffling, blurring · key-selection=unbounded randomized | Privacy-Preserving Remote Heart Rate Estimation from Facial VideosSource quoteL188: Ours │ 0.96 │ 1.30 │ 0.99 │ 0.89 │ 1.24 │ 0.99 |
| 2022 | Beam AI SDK proposed non-standard slice | MAE (heart rate estimation) | 0.65 beats per minute | Heart Rate Estimation · fps=30 FPS · frame-rate=30 fps | Real-Time Monitoring of User Stress, Heart Rate and Heart Rate Variability on Mobile DevicesSource quoteL33: Beam AI SDK │ 0.65 │ 0.77% │ 1.98 │ 0.99 |
| 2022 | FedWeight (signal-quality-weighted averaging) proposed | MAE (HR estimation) | 4.59 beats/min | Heart Rate Estimation · federated · training-data=AFRL · video-noise-level=1.50 | Federated Remote Physiological Measurement with Imperfect DataSource quoteL137: 1.50 │ 7.44 │ 4.59 │ -2.33 │ -0.03 │ 0.66 │ 0.79 |
| 2022 | TS-CAN baseline | MAE | 6.86 Beats/Min | Heart Rate Estimation · supervised · train-data=SCAMPS | rPPG-Toolbox: Deep Remote PPG ToolboxSource quoteL85: TS-CAN~\cite{liu2020multi} │ 6.86 │ 16.1 │ 6.68 │ 0.76 │ 6.67 │ 18.9 │ 7.93 │ 0.62 |
| 2022 | PhysNet baseline | MAE | 6.46 Beats/Min | Heart Rate Estimation · supervised · train-data=SCAMPS | rPPG-Toolbox: Deep Remote PPG ToolboxSource quoteL86: PhysNet~\cite{yu2019remote} │ 6.46 │ 12.2 │ 6.50 │ 0.823 │ 19.95 │ 27.57 │ 0.16 │ 31.54 |
| 2022 | DeepPhys baseline | MAE | 3.83 Beats/Min | Heart Rate Estimation · supervised · train-data=SCAMPS | rPPG-Toolbox: Deep Remote PPG ToolboxSource quoteL87: DeepPhys~\cite{chen2018deepphys} │ 3.83 │ 12.5 │ 3.62 │ 0.82 │ 3.46 │ 12.9 │ 3.53 │ 0.84 |
| 2022 | EfficientPhys-C baseline non-standard slice | MAE (heart rate estimation) | 1.14 beats per minute | Heart Rate Estimation · fps=30 FPS · frame-rate=30 fps | Real-Time Monitoring of User Stress, Heart Rate and Heart Rate Variability on Mobile DevicesSource quoteL36: EfficientPhys-C \cite{EfficientPhys_Liu2021} │ 1.14 │ 1.16% │ 1.81 │ 0.99 |
| 2022 | FedAvg baseline | MAE (HR estimation) | 7.44 beats/min | Heart Rate Estimation · federated · training-data=AFRL · video-noise-level=1.50 | Federated Remote Physiological Measurement with Imperfect DataSource quoteL137: 1.50 │ 7.44 │ 4.59 │ -2.33 │ -0.03 │ 0.66 │ 0.79 |
| 2020 | MetaPhys, supervised with pretraining proposed | MAE | 1.90 BPM | Heart Rate Estimation · pretraining=with-pretraining · training-regime=supervised | MetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological MeasurementSource quoteL166: Next, we examine the difference between a supervised and unsupervised training regime in MetaPhys\xspace. For UBFC, the supervised model (MAE=1.90 BPM), outperformed the unsupervised model (MAE=2.46 BPM). Whereas, for the MMSE dataset the unsupervised model (MAE=1.87 BMP) outperformed the supervised model (MAE=2.98 BMP). The fact that the unsupervised model achieves broadly comparable results to the supervised model is surprising and encouraging because there are many applications where unsupervised adaptation would be more convenient and efficient (e.g., calibrating a heart rate measurement app on a smartphone without needing a reference device). We also observe that the unsupervised model, even though it used the POS signal as training input, significantly outperforms POS on both datasets, suggesting MetaPhys\xspace is able to form a better representation. |
| 2020 | MetaPhys, unsupervised with pretraining proposed | MAE | 2.46 BPM | Heart Rate Estimation · pretraining=with-pretraining · training-regime=unsupervised | MetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological MeasurementSource quoteL166: Next, we examine the difference between a supervised and unsupervised training regime in MetaPhys\xspace. For UBFC, the supervised model (MAE=1.90 BPM), outperformed the unsupervised model (MAE=2.46 BPM). Whereas, for the MMSE dataset the unsupervised model (MAE=1.87 BMP) outperformed the supervised model (MAE=2.98 BMP). The fact that the unsupervised model achieves broadly comparable results to the supervised model is surprising and encouraging because there are many applications where unsupervised adaptation would be more convenient and efficient (e.g., calibrating a heart rate measurement app on a smartphone without needing a reference device). We also observe that the unsupervised model, even though it used the POS signal as training input, significantly outperforms POS on both datasets, suggesting MetaPhys\xspace is able to form a better representation. |
| 2020 | MetaPhys, unsupervised with pretraining proposed | MAE reduction | 44% | Heart Rate Estimation · pretraining=with-pretraining · training-regime=unsupervised | MetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological MeasurementSource quoteL163: In this section, we compare the performance of MetaPhys\xspace with other state-of-the-art approaches using Mean Absolute Error(MAE) of heart rate. Details of the evaluation metrics are in the Appendix section. For the MMSE dataset, our proposed supervised and unsupervised MetaPhys\xspace with pretraining outperformed the state-of-the-art results by 7% and 42% in MAE, respectively (see Table \ref{tab:AFRL_MMSE}). On the UBFC dataset, supervised and unsupervised MetaPhys\xspace with pretraining showed even greater benefits reducing error by 57% and 44% compared to the previous state-of-the-art, respectively. Meta-learning alone is not as effective as meta-learning using weights initialized in a pretraining stage (19% and 50% improvements in MMSE and UBFC). We also compared our methods against the only other meta-learning based method (Meta-rPPG) where we reduced the MAE by 68%. Furthermore, we compared MetaPhys\xspace against a traditional personalization method (fine-tuning), and our approach gained 54% and a 61% improvements in terms of MAE on MMSE and UBFC, respectively. We also evaluated performance using different time windows in the support set (6s, 12s and 18s), and the results showed training with 18s (RMSE: 3.12) outperformed 6s (RMSE: 5.43) and 12s (RMSE: 5.53) on the MMSE dataset. A similar trend was also observed on the UBFC dataset (RMSE of 18s: 3.12, RMSE of 12s: 4.48, RMSE of 6s: 3.46). Fig. \ref{fig:blandaltman} compares the heart rate estimates from MetaPhys\xspace and the-state-of-art algorithm (TS-CAN \cite{liu2020multi}) (y-axes) to the gold-standard measurements (x-axes). The strong correlation coefficients and bias/limits in the Bland-Altman plots presented support that MetaPhys\xspace can produce more accurate and reliable estimates. Our results from unsupervised MetaPhys\xspace indicate that pesudo labels provided by a relatively simple de-mixing approach (POS) can be used in a meta-learning context to obtain strong results. The training with these pseudo labels, sometimes with noisy labels, well outperforms the de-mixing approach itself. |