TCGA

90 papers · 247 extracted observations · survival prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Survival Analysis: proposed/measured results on val (including papers where val split is standard/implicit).

0.70.70.70.720262027IPGPhormer: 0.657 (2025)KHiM-Mamba: 0.7394 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 5 of 5 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026AdaptivePath (Slide) proposedaccuracy80.14%Cancer Subtype Classification · 0-shot · input=H&E only · cohorts=six · sample-size=700 WSIsAgentic Visual Reasoning in Whole-Slide Pathology Images via Active Perception
Source quote
L296: 80.14
2026SlideChat (Slide) baselineaccuracy65.29%Cancer Subtype Classification · 0-shot · input=H&E only · cohorts=six · sample-size=700 WSIsAgentic Visual Reasoning in Whole-Slide Pathology Images via Active Perception
Source quote
L273: 70.86 │ 71.26 │ 46.81 │ 65.29
2025Virchow + FG-PAN proposedBal. acc.0.772Brain Tumor Subtype Classification · 0-shot · classes=2Enhancing zero-shot brain tumor subtype classification via fine-grained patch-text alignment
Source quote
L224: Bal. acc. │ 0.712 │ \bfseries 0.753 │ 0.763 │ \bfseries 0.785 │ 0.679 │ \bfseries 0.797 │ 0.735 │ \bfseries 0.772 │ 0.713 │ \bfseries 0.745 │ 0.710 │ \bfseries 0.731
2025Virchow (Base, without FG-PAN) baselineBal. acc.0.735Brain Tumor Subtype Classification · 0-shot · classes=2Enhancing zero-shot brain tumor subtype classification via fine-grained patch-text alignment
Source quote
L224: Bal. acc. │ 0.712 │ \bfseries 0.753 │ 0.763 │ \bfseries 0.785 │ 0.679 │ \bfseries 0.797 │ 0.735 │ \bfseries 0.772 │ 0.713 │ \bfseries 0.745 │ 0.710 │ \bfseries 0.731
2025Leading pathology foundation models (UNI, GigaPath, and Virchow) baselineF1~68%Image Retrieval · split: val · 0-shot · models=UNI, GigaPath, Virchow · organ-subgroup=kidney · retrieval-rank=top-1Why Foundation Models in Pathology Are Failing
Source quote
L22: Despite their size and ambition, these models managed only 40–42% macro-averaged F1 for top-5 retrieval and showed wide, clinically unacceptable variability from one organ system to another: kidneys reached up to ~68% (top-1 F1)\footnote{Outlier organ performance, such as the unusually high kidney F1 scores, may partly reflect genuine morphological distinctiveness—but could also indicate data leakage or hidden technical bias.